Job:
Engineer:
Contractor:
Prepared By: Date:
Versatile
• For use with pool and spa heaters
• Permits sidewall venting
• Allows use of vent pipe as small as 4 in.
diameter
Efficient
• Maintains thermal efficiency of 82% on all
heater sizes
Multi-Position Capability
• 90° elbow can be rotated to align fan
discharge with vent pipe and reduce the
number of fittings required
D-2 Power Vent
For Pool & Spa Heaters
Models 206-407
Features
Induced draft
Vent (Category III) runs up to 100 ft. equivalent length
Plenum sized for appliance capacity
Air flow proving switch, mounted and wired
Fan motor relay, mounted and wired
240/120 Volt, 60 Hz, 1.95/1.0 Amp, 130 CFM Max.,
3200 RPM motor; Factory-wired for 240 Volt
90° elbow is used as a termination cap for
horizontal venting
Heavy-duty galvanized steel cabinet
PolyTuf textured powder coat finish
Indoor/Outdoor construction
Easy installation
Limited one-year warranty
Shipped loose for field mounting
Catalog No.: 1000.70A Effective: 10-15-07 Replaces: 5-1-05
D-2 Power Vent
For Heater Models 206-407 Heater Model
18-1/8
7-7/8
4" DIA
11-5/8
B
D
Heater
Model
206/207 009832 12-3/8 4-1/4
266/267 009832 12-3/8 4-1/4
336/337 009833 18-1/8 7-1/4
406/407 009833 18-1/8 7-1/4
* Part numbers are for 240 VAC units.
Consult factory for 120 VAC units.
NOTES:
1. All units can exhaust flue gases horizontally or
vertically at up to 100 ft. of equivalent length
vent pipe
- 90° elbow = 10 ft. equivalent length
- 45° elbow = 5 ft. equivalent length
2. Vent pipe must meet Category III appliance
venting requirements.
3. Vent pipe sizes are based on 400°F nominal
flue temperature and sea-level operation. For
installation under other conditions, please
consult the factory.
Power Vent
Part No.*
Dimensions (in.)
B D
Catalog No.: 1000.70A Effective: 10-15-07 Replaces: 5-1-05