Boosts thermal efficiency to 98% at full fire!
The Raypak Condensing Heat Exchanger (CHX)
utilizes exhaust heat, which is normally wasted,
and converts it to useful energy that increases
overall operating efficiency. By isolating corrosive
condensation in the CHX, away from the primary
combustion chamber, the life of the boiler/heater
is extended.
Applications
• Domestic Hot Water
• Pool Heating
• Hydronic Heating
Available Configurations
• Top-mounted CHX
• Rear-mounted CHX
• Stacked boilers/CHXs
CHX Features
CHX
Top-mounted configuration shown
Hi Delta
boiler/heater
• Finned cupro-nickel tubes with patented epoxy coating
• All bronze headers
• Traditional Raypak tube sheet design with high-temperature silicone O-rings
• ASME tested to 160 PSIG working pressure
• AL29-4C stainless steel casing
• PolyTuf powder coating on outer shell
• Indoor/outdoor construction (32°F+ ambient temperatures)
• Condensate drain connection
• Limited twenty-year thermal shock warranty
• Ten-year limited warranty
• National Board approved
• Installation components and kits available
Catalog No.: 1000.81B Effective: 7-15-08 Replaces: 6-1-05
CHX for Hi Delta Model
CHX
Dimensions
are in inches
Hi Delta with CHX
Top CHX Rear CHX Stacked CHXs
CHX HI DELTA WITH CHX
Hi Delta/ MBTUH A B* F* P* U* M* T K H Ship.Wt.
CHX Model Input Output Width Height NPT NPT (lbs) X Y Z X Y Z X Y Z
402/500-6
502/500-6
652/500-8
752/750-8
902/750-8
992/1000-10
1262/1000-10
1532/1500-12
1802/1500-14
2002/1500-14
399 391
500 490
650 637
750 735
900 882
990 970
1260 1235
1530 1499
1800 1764
1999 1959
23-1/4 24-11/16 18-3/4 11 22-1/4 13-3/4 1/2 6 2 250 61-1/2 66-1/2 39-1/2
23-1/4 24-11/16 18-3/4 11 22-1/4 13-3/4 1/2 6 2 250 65-1/2 66-1/2 39-1/2
23-1/4 24-11/16 18-3/4 11 22-1/4 13-3/4 1/2 8 2 250 75 66-1/2 39-1/2
23-1/4 30-11/16 24-1/8 15 27-3/4 16-1/2 1/2 8 2 275 78 71 39-1/2
23-1/4 30-11/16 24-1/8 15 27-3/4 16-1/2 1/2 8 2 275 83-1/2 71 39-1/2
28-3/4 39 33 21-5/8 36-5/8 20-5/8 1/2 10 2-1/2 300 75 89-1/2 46-1/2
28-3/4 39 33 21-5/8 36-5/8 20-5/8 1/2 12 2-1/2 300 81-1/2 89-/12 46-1/2
34-1/4 49 42 19-1/2 46 20 3/4 12 2-1/2 350 88 99-1/2 46-1/2
34-1/4 49 42 19-1/2 46 20 3/4 14 2-1/2 350 102-1/2 99-1/2 46-1/2
34-1/4 49 42 19-1/2 46 20 3/4 14 2-1/2 350 108 99-1/2 46-1/2
* Dimension can be increased approx. 2” using adjustable feet
Top CHX Rear CHX Stacked CHXs
43 56 57
50 56 57
60-1/2 56 58-1/2
67-1/2 56 58-1/2
78 56 58-1/2
57-1/2 65-1/2 73-1/2
68-1/2 65-1/2 73-1/2
80 65-1/2 73-1/2
91-1/2 65-1/2 78-1/2
102-1/2 65-1/2 78-1/2
48-1/2 77-1/2 68-1/2
55-1/2 77-1/2 68-1/2
66 77-1/2 71
73 80 71
83-1/2 80 71
62-1/2 102 110-1/2
74 102 108
85-1/2 112 108
96-1/2 112 115-1/2
107-1/2 112 115-1/2
RATES OF FLOW AND PRESSURE DROPS
Model
Hi Delta CHX
402 500-6 34 1.5 0.5 22 <1.0 0.2 N/A N/A N/A 90 10.0 7 3.0 1.2
502 500-6 42 2.3 0.8 28 1.1 0.4 21 <1.0 0.2 90 10.5 9 3.0 1.5
652 500-8 55 4.0 1.2 36 1.8 0.6 28 1.0 0.4 90 10.7 12 3.0 2.0
752 750-8 64 5.5 2.0 42 2.5 0.9 32 1.4 0.5 90 11.0 14 3.5 2.3
902 750-8 76 8.3 2.6 51 3.8 1.2 38 2.1 0.7 90 11.8 17 3.5 2.8
992 1000-10 84 5.6 4.0 56 2.5 1.9 42 1.4 1.1 132 14.0 13 9.2 2.2
1262 1000-12 107 10.0 6.2 71 4.5 2.9 54 2.5 1.8 132 15.5 16 9.2 2.7
1532 1500-12 130 16.0 10.0 86 7.1 4.7 65 4.0 2.6 132 16.5 20 10.1 3.3
1802 1500-14 N/A N/A N/A 102 10.8 6.3 76 6.0 3.7 132 18.0 23 10.1 3.8
2002 1500-14 N/A N/A N/A 113 14.0 7.7 85 8.1 4.5 132 19.5 26 10.1 4.3
20˚F ∆∆∆∆T 30˚F ∆∆∆∆T 40˚F ∆∆∆∆T
Flow
(GPM)
∆∆∆∆P (ft) ∆∆∆∆P (ft) ∆∆∆∆P (ft)
Hi Delta CHX
Flow
(GPM)
Hi Delta CHX
Flow
(GPM)
Hi Delta CHX
Maximum Flow
Hi Delta CHX
GPM
∆∆∆∆P (ft) ∆∆∆∆T (˚F) ∆∆∆∆P (ft) ∆∆∆∆T (˚F)
For Hydronic applications, minimum flow rates are
at 40˚F ∆T, except on model 402 which is 20 GPM.
For Pool applications, use 20˚F ∆T or Maximum
Flow column, as appropriate.
For series piping, add the pressure drop of the
boiler, CHX and piping to size the pump.
For dual-pumped Domestic Hot Water, size the
heater pump for the pressure drop of the selected
heater plus the pressure drop of the piping. Size the
CHX pump for 40 GPM @ 0.7 ft. of head for models
402 to 902 and for 60 gpm @ 2.2 ft of head for
models 992 to 2002 plus the piping.
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (800) 872-9725 www.raypak.com