Medical Image Processing Unit
1012WCA
User Manual
© Copyright 2012, Rayence Co. Ltd.
All pages of this document contain proprietary and confidential
information of Rayence Corporation and are intended for exclusive use
by Rayence Corporation personnel or customers. Copying, disclosure to
others or other use is prohibited without the express written
authorization from Rayence Corporation. Please report any violations of
requirement to Rayence Corporation.
R-M-011-121030
Attention
For improvement of product performance, supplementation, or follow-up of information; the
contents of this manual are subject to change without separate prior notice.
Please note that our company has neither responsibility for any accidents nor obligation to
do free repair service for any damage of the equipment due to user's mistake, which resulted
from failure to follow the contents in this manual. Make sure to be familiar with the safety
precautions and usage procedures. Also note that the product may slightly differ from the
contents of this manual depending on specification.
The following marks are used for the effective use of the product in this manual.
Attention, consult accompanying documents.
This is used to emphasize essential information. Be sure to read this
information to avoid incorrect operation.
This indicates hazardous situation which, if not heeded, may result in
minor or moderate injury to you or others, or may result in machine
damage.
This indicates a potentially hazardous situation which, if not heeded, could
result in death or serious injury to you or others.
Federal Law restricts this device to sale by or the order of a radiologist or
any other practitioners licensed by the law of the state in which that
person practices to use or order the use of the device.
Contents
Introduction ........................................................................................ 1
Intended use ...................................................................................... 1
Product features ................................................................................ 2
Product components ......................................................................... 3
Components Description................................................................... 5
Warning .............................................................................................. 8
Caution ............................................................................................. 10
Marking and labeling symbols ........................................................ 12
Notes for Using the Detector ............................................................ 14
Preparing .......................................................................................... 14
Handling ........................................................................................... 15
Handle Assembly ............................................................................. 15
Before Exposure .............................................................................. 17
During Exposure .............................................................................. 17
Limit of Load .................................................................................... 19
Disinfection and Cleaning ............................................................... 20
Others ............................................................................................... 20
Technical Features ........................................................................... 21
Mechanical Features ........................................................................ 21
Electrical Features ........................................................................... 21
Environmental requirement ............................................................. 24
PC Requirements ............................................................................. 24
Installation........................................................................................ 25
General interface ............................................................................. 25
Connection ....................................................................................... 25
IP set up ........................................................................................... 31
Using Web Manager (IP, SSID Change / Upgrade FW) ................... 32
Calibration ........................................................................................ 36
General Principle ............................................................................. 36
Calibration ........................................................................................ 38
Image Acquisition Test ..................................................................... 43
Program setup ................................................................................. 43
Get Image ......................................................................................... 44
View Images ..................................................................................... 45
Operation .......................................................................................... 50
Recommend ..................................................................................... 50
Switching power on / off .................................................................. 50
Storage ............................................................................................. 50
Information ....................................................................................... 51
Safety standard ................................................................................ 51
Electromagnetic Compatibility Information .................................... 53
FCC Notice ....................................................................................... 53
Maintenance ..................................................................................... 60
Maintenance ..................................................................................... 60
Cleaning ........................................................................................... 60
Inspection ........................................................................................ 61
Disposal or Recycling...................................................................... 62
Appendix ........................................................................................... 63
R-M-011-121030
Introduction
Overview
The 1012WCA is a wireless digital X-ray flat panel detector that
can generate images of any part of the body. The wireless
LAN((IEEE 802.11a/g/n) communication feature improves the
operability, and high-speed processing. This X-ray imaging
system consists of a scintillator directly coupled to an a-Si TFT
sensor. It makes high-resolution, high-sensitive digital images.
Intended use
For U.S.A.
1012WCA Digital Flat Panel X-Ray Detector is indicated for
digital imaging solution designed for human anatomy including
head, neck, spinal column, arm, leg and peripheral (foot, hand,
wrist, fingers, etc.). It is intended to replace film based
radiographic diagnostic systems and provide a case diagnosis
and treatment planning for physicians and other health care
professionals. Not to be used for mammography.
For European Union
This device provides digital X-ray imaging for diagnosis of
disease, injury, or any applicable health problem. The image is
obtained as the result of imaging X-rays passed through the
human body with an X-ray flat panel detector and importing a
digital signal output from the detector into the image processor.
1
Product features
Wi-Fi (802.11a/g/n)
Based on a-Si TFT active matrix
Compact (18mm thickness) and light weight (Typ. 3.15kg)
Limiting Resolution : 3.9 lp/mm
16-bit digital output
Easy integration
R-M-011-121030
Product components
Medical Image Processing Unit
Detector SD1012WCA 1
Handle - 1
Battery pack RB37WH 2
Battery charger RC120W 1
Charger adapter PMP120-13-3 1
AGI RA001A 1
3
Cables
Link cable VRH076A 6m 1
PInterface
VRH017A 8m 1
cable
USB
cable (A
to B)
AC Power
cord
Installation CD
o Manual
o Detector Library
VRH078A 1.8m 1
VRH018A/019A 1.8m 1
Option
o Additional Battery
o Charger for the Car
o Cover Bag
o AP package
R-M-011-121030
Components Description
The detector is designed to capture radiographic images.
Captured images are transmitted to PC using the wireless/wired
connection.
(1) Detector
1. LED indicator: The LED indicates the state of detector.
i. Green on : Power on.
ii. Blue blinking : Wireless Connection.
iii. Orange on : Low battery.
2. Handle : Hold this handle when carrying the sensor unit. It is
removable. (Horizon / Vertical)
3. Handle unlock-lever : This is an unlock-lever to remove handle.
4. Link cable connector : This is a connector for Wire communication
5
and power supplying. Connect the detector to PC and SMPS(not
provided) using Link cable.
5. CFRP(Carbon Fiber Reinforced Plastic) : The part of the patient’s
body to which an image is to be taken should be placed against this
plate.
6. Power button : Power on / Power off switch.
7. Shock sensor : Detector has built-in 4 Shock sensors. It detects
and records impact and mishandling of fragile
8. Battery unlock-lever : This is an unlock-lever to remove battery.
(2) Battery & Charger
1. Battery : Lithium ion battery. The number of times being acquired
image is 600 images(@ cycle time : 15s). The batteries last 2.5
hours and are rechargeable.
2. Charger : Two port cradle type.
3. LED indicator :
i. Orange on : charging
ii. Green on : Charging is completed.
R-M-011-121030
(3) AGI
1. Trigger connector: This is a connector for synchronization
2. USB connector: This is a connector for communication between
between detector and generator. Connect the AGI to the generator
using P-interface cable..
AGI and PC. Connect the AGI to the PC using USB cable.
7