TRANSMISSION
INDICATOR LIGHT
OPERATION GUIDE
STOP BUTTON
Press to immediately stop
all active bed functions.
FLAT BUTTON
Press to return bed
to the level position.
HEAD UP/DOWN BUTTON
Press and hold to raise or
lower the head section.
PROGRAM SET BUTTON
Press to capture any position
of the bed as a programmed
position (3 unique positions).
Press the recall buttons (“P1,
P2 or P3”) to return bed to
any of the preset positions.
To Program Preset Positions:
1. Set the head and/or foot to
the desired position.
2. Press the program set button
once.
3. Press position recall button
“P1” to save position.
4. Repeat steps 1 thru 3 above
to program favorite positions
for “P2” and “P3”.
HEAD MASSAGE BUTTON
Press the “+” symbol to activate the
head massager at a preset intensity.
Press and hold the “+” symbol to
intensify head massager. Press and
hold the “–” symbol to decrease head
massager intensity.
NEUROSAGE WAVE INTENSITY BUTTON
Press and hold the “+” symbol to intensify
Neurosage wave intensity. Press and hold
the “–” symbol to decrease Neurosage
wave intensity.
FOOT UP/DOWN BUTTON
Press and hold to raise or
lower the foot section.
POSITION RECALL BUTTONS
Press to activate a position set
by the program button.
FOOT MASSAGE BUTTON
Press the “+” symbol to
activate the foot massager at
a preset intensity. Press and
hold the “+” symbol to
intensify foot massager. Press
and hold the “–” symbol to
decrease foot massager
intensity.
NEUROSAGE ON/OFF BUTTON
Press to activate or deactivate
the Neurosage wave vibration
system.
MASSAGE NOTE:
When activated, the massage system will launch the prior intensity setting used and automatically
shut off after 30 minutes. To restart Neurosage wave, press the Neurosage on/off button. To restart
head or foot massagers, press the “+” symbol on the head or foot massage button/s.
IMPORTANT:
Read advisory information in the owners manual carefully before using this product. The
potential for electrical shock exists if electrical components are not installed or operated
properly.
See back of page for additional programming features...
Document Part No. 99300799
www.lpadjustablebeds.com
EDR10488 4/05
© Leggett & Platt, Inc.
4002 PROGRAMMING
To set channels on a single base:
4002 BATTERY REPLACEMENT
Requires (2) CR2032 3 volt batteries.
1. Plug the bed into a power
source and within 30 seconds,
press the head up button on
the hand control until the
transmission indicator light
illuminates. This will confirm
that the hand control and the
bed are communicating.
2. The hand control channel is
now programmed.
To set channels for 2 or more
beds to operate independently:
1. Unplug all beds from their
power sources.
2. Plug in the first bed to be
programmed and within 30
seconds, press the head up
button on the hand control until
the transmission indicator light
illuminates. This will confirm
that the hand control and the
bed are communicating.
3. Repeat steps 1 and 2 with each
base requiring programming (It
is important to use the specific
hand control that will be used
to operate the bed). Beds prior
programmed with the remote
need not be unplugged.
REMOVAL:
1. Remove the battery
compartment cover
located on the back of
the hand control
(FIGURE 1).
2. Press the roundshaped tab (FIGURE 2)
and each battery will
eject from the plastic
captive clip (FIGURE 3).
3. Grasp and remove
batteries. Note
position of batteries
when removing for
replacement.
PUSH DOWN
ON TAB TO
EJECT BATTERIES
FIGURE 2
BATTERIES
PUSH IN (SLIGHTLY)
AND SLIDE OFF
BATTERY
COMPARTMENT
COVER
REPLACEMENT:
4. Position the new
batteries face-up
and insert into the
plastic captive clips
(reverse of removal).
5. Carefully push
batteries in and
down to install.
6. Replace battery
compartment cover.
FIGURE 1
4. Multiple beds are now
programmed for independent
operation.
Note: In the event of power
failure or if bed is inadvertently
unplugged from the electrical
power source, wait 30 seconds
(after power is restored) before
using any hand control. This
will prevent bases from
learning and working
simultaneously.
FIGURE 3
WHEN BATTERY EJECTS
FROM CAPTIVE CLIP,
ROTATE UP AND OUT
OF BATTERY
COMPARTMENT
TO REMOVE