General Specifications
RF-0300 Ice Machine
Refrigerant Charge (R-404A)
Heat of Rejection (Btu/Hr) 3500
Ice Making Water Inlet 3/8" FPT (Female Pipe Thread) A backflow preventer is required
Potable Water
Water Temperature - Minimum 40°F (4°C) Maximum 90°F 32°C)
Water Pressure - Minimum 20 psig (1.38 bar) Maximum 80 psig (5.52 bar)
Ice Making Water Dra in 1/2" FPT (Female Pipe Thread)
Compressor: Nominal Rating 1 HP
Ambient Temperature Range Minimum 45°F (10°C) Maximum 110°F (43°C)
Voltage
(Minimum Circuit Amperage)
208-230/60/1 10 amps 15 amps
230/50/1 amps 10 amps
Outside Cabinet Dimensions Height - 27.50" (700 mm) Width - 25.20" (640 mm) Depth - 18.5" (470 mm)
Air
11.25 oz / 320 g.
Air-Cooled Maximum Circuit Breaker
MII-044
11/11
RF-0300A
Characteristics will vary depending on operating conditions.
ICE PRODUCTION
Air Temperature/
Water Temperature
70°F/50°F 311 lbs 6.48
90°F/70°F 259 lbs 6.48
21°C/10°C 141 kgs 6.48
32°C/21°C 117 kgs 6.48
OPERATING PRESSURES PSIG & kPa
Air Temperature
Entering
Condenser
70°F PSIG
21°C kPa
90°F PSIG
32°C kPa
110°F PSIG
43°C kPa
24 hour
Ice Production
Freeze Cycle
Discharge
Pressure
230-255
1585-1758
250-280
1724-1930
325-350
2240-2413
kWh/100 lbs
kWh/45 kg
Suction
Pressure
28-31
193-214
30-36
207-248
32-38
221-262