Installation & Operation Manual
Alarm Board Wiring- SmartPhone VI
Installation Instructions:
• Run one set of wires (22-24ga shielded recommended) from the screw terminals labeled ALARM on the RATH
®
SmartPhone to any of the paired sets of terminals labeled TB2 or TB3 on the Junction Board. Up to 10 phones can
be connected to a single Junction Board. The Junction Board can be mounted in the machine room or by the Alarm
Board at the landing panel.
Note: Do not provide a connection to the SmartPhone alarm terminal that has voltage on it.
• Connect 24vdc to the terminal labeled Power on the Junction Board. The terminals are not polarity sensitive.
• Run a set of wires (22-24ga shielded recommended) from the screw terminals labeled Alarm on the Junction Board
to the screw terminals labeled TB1 on the Alarm Board.
• Connect the LED wires to the screw terminals labeled TB2 on the Alarm Board (Connection 1 is Negative,
Connection 2 is Positive).
• If connecting an external key switch, connect the wires from the key switch to the screw terminals labeled TB3 on
the Alarm Board. Key switch should be set to Normally Open.
Testing:
• Disconnect the phone line from the RATH® SmartPhone. The alarm will sound within 13-14 minutes (once the test
is done you can then program the phone to check the line at a longer interval up to 23 hours or leave it at 10
minutes). Otherwise, you can disconnect the phone line from the SmartPhone and press the phone push button.
This will sound the alarm in 3-4 minutes.
• In alarm state, the LED will flash and the piezo will sound. There are three ways to reset the alarm status:
1. Press the Reset Button located on the Alarm Board. This will temporarily turn off the piezo buzzer (it will resound
within 24 hours, unless phone line is restored).
2. If an external key switch is connected to the Alarm Board, turn the key switch. This will temporarily turn off the
piezo buzzer (it will resound within 24 hours, unless phone line is restored).
3. To turn off the LED and the piezo buzzer, reconnect an active phone line. The phone will reset the Alarm Board
after a few seconds.
Troubleshooting:
• To test the LED and the piezo on the Alarm Board, and to make sure it is properly connected to the Junction Board,
press the button labeled PB1 on the Junction Board. This should cause the LED to flash and the piezo buzzer to
sound.
• If the alarm is always going off on the phone, verify that the line check on the SmartPhone is turned on by pressing
Enter, 23 Enter 3, 23 Enter 7284, 11 Enter 1.
• Verify Alarm Terminals on SmartPhone show NO when phone line is connected, and closed when phone line is
pulled from phone and it is in an alarm state.
• If the LED on the Alarm Board is blinking but piezo is not sounding, verify key switch is not set to Normally Closed
instead of Normally Open.
Alarm Board Wiring:
Elevator
RATH®
SmartPhone
Machine Room or Landing Panel
Junction Board
BT
ralA
TB3
4
m
PB1
vac/vdc
Landing Panel
TB2
External
Key Switch
Set to NO
Alarm Board
TB2 TB3
Reset
Button
LED
Connection 1: Negative
Connection 2: Positive
24
rew
1BT
o
P
1BT
Piezo
MADE IN THE USA
3 YEAR WARRANTY
N56W24720 N. Corporate Circle • Sussex, WI 53089
800-451-1460 • www.rathcommunications.com
RP8500ALARM
Ver. 11
03/21