Raritan Computer MasterConsole Z User Manual

MasterConsole
Z
User Manual
MCZ-0B-E
May 2006
255-33-1200
This page intentionally left blank.
D
Copyright and Trademark Information
This document contains proprietary information that is protected by copyright. All rights reserved. No part of this document may be photocopied, reproduced, or translated into another language without express prior written consent of Raritan Computer, Inc.
© Copyright 2006 Raritan, MasterConsole, Paragon, and the Raritan company logo are trademarks or registered trademarks of Raritan Computer, Inc. All rights reserved. Java is a registered trademark of Sun Microsystems, Inc. Internet Explorer is a registered trademark of Microsoft Corporation. Netscape and Netscape Navigator are registered trademarks of Netscape Communication Corporation. All other marks are the property of their respective owners.
FCC Information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential environment may cause harmful interference.
Japanese Approvals
Raritan is not responsible for damage to this product resulting from accident, disaster, misuse, abuse, non-Raritan modification of the product, or other events outside of Raritan’s reasonable control or not arising under normal operating conditions.
U
C
LISTE
1F61
US
L
I.T.E.
For assistance in the North or South America, please contact the Raritan Technical Support Team
by telephone (732) 764-8886, by fax (732) 764-8887, or by e-mail
tech@raritan.com
Ask for Technical Support – Monday through Friday, 8:00am to 8:00pm, Eastern.
For assistance around the world, please see the last page of this guide for
regional Raritan office contact information.
Safety Guidelines
To avoid potentially fatal shock hazard and possible damage to Raritan equipment:
Do not use a 2-wire power cord in any product configuration.
Test AC outlets at your computer and monitor for proper polarity and grounding.
Use only with grounded outlets at both the computer and monitor. When using a backup UPS,
power the computer, monitor and appliance off the supply.
Rack Mount Safety Guidelines
In Raritan products which require Rack Mounting, please follow these precautions:
Operation temperature in a closed rack environment may be greater than room temperature.
Do not exceed the rated maximum ambient temperature of the appliances (see Appendix A: Specifications).
Ensure sufficient airflow through the rack environment.
Mount equipment in the rack carefully to avoid uneven mechanical loading.
Connect equipment to the supply circuit carefully to avoid overloading circuits.
Ground all equipment properly, especially supply connections, such as power strips (other
than direct connections), to the branch circuit.
CONTENTS i
Contents
Chapter 1: Introduction .................................................................. 1
MasterConsole Z Overview.........................................................................................1
Product Photos............................................................................................................1
Product Features.........................................................................................................2
User Station (MZUST) Features .................................................................................3
Chapter 2: Installation.................................................................... 5
Pre-configuration Notes ..............................................................................................5
Hardware Installation ..................................................................................................5
Chapter 3: Operation ...................................................................... 9
OSD Functions............................................................................................................9
Help Menu.......................................................................................................................................10
Administration Menu........................................................................................................................12
Appendix A: Specifications .......................................................... 15
Appendix B: Troubleshooting ....................................................... 17
Appendix C: Glossary ................................................................... 19
Appendix D: FAQs ......................................................................... 21
UTP Cabling FAQs....................................................................................................25
ii FIGURES
Figures
Figure 1 MasterConsole Z User Station (MZUST)....................................................................................... 1
Figure 2 MasterConsole Z Computer Interface Module (MZCIM-PS2)........................................................1
Figure 3 MZCIM-USB ..................................................................................................................................2
Figure 4 MZCIM-SUN ..................................................................................................................................2
Figure 5 MZCIM Installation........................................................................................................................5
Figure 6 On-Screen Display (OSD)..............................................................................................................7
Figure 7 MZUST Selection Menu Screen ....................................................................................................9
Figure 8 F1 Help Menu ..............................................................................................................................10
Figure 9 Selection Menu by Name.............................................................................................................10
Figure 10 CIM Configuration Menu...........................................................................................................11
Figure 11 Administrative Menu ..................................................................................................................12
Figure 12 User Station Information Menu ..................................................................................................12
Figure 13 User Security Profile Menu........................................................................................................ 13
Figure 14 User Preferences Screen...........................................................................................................13
CHAPTER 1: INTRODUCTION 1

Chapter 1: Introduction

MasterConsole Z Overview

The MasterConsole Z switchless access system consists of two components – a User Station (MZUST) and an MZ-Computer Interface Module (MZCIM), connected with Enhanced Category 5e UTP cable. The MZCIMs are linked in a chain via Category 5e UTP cable, and servers are connected to each of the MZCIMs. Please note that these MZCIMs are not compatible with P2ZCIMs or ZU4200 CIMs.
With a MasterConsole Z system, you can:
Add a computer anywhere in the chain at any time
Hot connect a user console to any server
Hot-swap components with no impact on server operation
Select computers by name from on-screen menus
Locate user up to 700 feet (213m) away with Category 5e UTP cable

Product Photos

Figure 1 MasterConsole Z User Station (MZUST)
Figure 2 MasterConsole Z Computer Interface Module (MZCIM-PS2)
2 MASTERCONSOLE Z USER GUIDE
Figure 3 MZCIM-USB
Figure 4 MZCIM-SUN

Product Features

Innovative zero-U design supports up to 64 computers, any combination of PS/2, USB, and
SUN, on a single Cat5 chain
Simple Plug and Play installation
Keep-alive keyboard/mouse emulation for flawless operation
Password authorization
PC share/video share capability
User Station supports PS/2 or USB keyboards and mice
Automatic Video Tuning (AVT) adjusts video quality automatically
Supports high-resolution video to 1024X768
Admin Port for on-site flash firmware upgrade of the User Station and MZCIMs
Long-cable MZCIMs for servers with cable management arms
CHAPTER 1: INTRODUCTION 3

User Station (MZUST) Features

Front Panel
Status LED: Indicates power and operational status of MZUST User Station
Rear Panel
AC Power:
Connector: for AC power cable (100V – 240 VAC, 47 Hz – 63 Hz)
On/Off Switch: for powering ON or OFF the MZUST User Station
PS/2 Keyboard: Connect PS/2 keyboard to operate MZUST.
PS/2 Mouse: Connect PS/2 Mouse to operate MZUST.
VGA Monitor: Connect multisync VGA monitor to view connected computers.
Cat5 Ports In: Connect up to 64 computers, using Cat5 UTP cable and a chain of MZCIMs.
Cat5 PC Share OUT: Connect (pass through) a second MZUST User Station.
USB K/M: Connect a USB keyboard/mouse to operate the MZUST User Station.
Admin: Proprietary serial port used to upgrade MZUST and MZCIM firmware. When
available, new firmware will be posted on Raritan website http://www.raritan.com.
4 MASTERCONSOLE Z USER GUIDE
CHAPTER 2: INSTALLATION 5

Chapter 2: Installation

Pre-configuration Notes

MasterConsole Z installation requires that a Port Name is assigned to each computer as it is added to the MZCIM chain during installation. Ports are organized alphabetically by assigned name or by the default name (the MZCIM’s serial number), not by order of placement in the MasterConsole Z chain. Raritan recommends that you assign port names as you connect computers instead of connecting all computers first and then assign port names – it may be difficult to locate the respective port for each computer.

Hardware Installation

Important: MZUST must be powered OFF prior to installation.
1. Install MasterConsole Z User Station (MZUST): A. Connect one end of an AC power cable to the MZUST and plug the other end of the
power cord into an AC power source.
B. Connect a PS/2 (or USB) key board, VGA monitor, mouse to the appropriate ports on the
rear panel of the MZUST.
C. Plug in and power ON the VGA monitor. D. Power ON the MZUST using the AC Power switch on the rear panel.
Figure 5 MZCIM Installation
2. Connect Computers to MZUST using MZCIMs
2.1 For MZCIM-PS2: A. Attach an MZCIM-PS2 video (HD15) connector to the computer’s video port. B. Connect the MZCIM-PS2 keyboard and mouse connectors to the computer’s keyboard
and mouse ports.