Rangemaster WP29M User Manual

WP29M SERIES
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE, CARE AND OPERATION INFORMATION
ON PAGES 10 AND 11.
SV07693 rev. G
HB0058
READ AND SAVE THESE INSTRUCTIONS
!
!
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711 BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
REGISTER YOUR PRODUCT ON LINE AT: www.BestRangeHoods.com/register
For additional information - visit www.BestRangeHoods.com
WARNING WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power
off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN—You may
be burned.
3. DO NOT USE WATER, including wet dishcloths or
towels—This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area
where it started.
C. The fire department has been called. D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
!
!
1. For indoor use only.
2. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced.
5. For best capture of cooking impurities, the bottom of the hood should be at a minimum of 24” and at a maximum of 30” above the cooking surface.
6. Two installers are recommended because of the large size and weight of this hood.
7. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside—Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
9. To reduce the risk of fire and electric shock, the Best WP29M Series hood must be installed with Best interior blower models
P6 or P12; Best exterior blower
models
EB6, EB9, EB12 or EB15; Best inline blowers models ILB3, ILB6, ILB9, ILB11. Other blowers cannot be substituted. (Blowers sold separately.)
10. Please read specification label on product for
further information and requirements.
- 3 -
Model 415
(7” round adjustable elbow)
Model 427
(4½” x 18½”
to 10” Round,
6” high - lateral
Model 423
(4½” x 18½”
to 10” Round -
vertical
Model 424
(4½” x 18½”
to 10” Round -
horiz. front/rear
Model 454
(4½” x 18½”
to 10” Round -
horiz. /right
Model 453
(4½” x 18½”
to 10” Round -
horiz. /left
WP29M
SERIES HOOD
(Canopy with
blower controls
& lighting.
Required for all
installations.)
OPTIONAL DECORATIVE FLUE AEWP SERIES
OPTIONAL
FLAT TOP COVER
ADPWP SERIES
NON-DUCT KIT FLUE
ANKWP SERIES
NOTE: For a non-ducted installation, we
recommend the non-duct kit flue ANKWP Series be installed with Model P6 Blower/Rough-in kit for effectiveness.
- WP29M SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
Model 437
(High capacity roof cap)
Model 441
(10’’ Round wall cap)
Model 634 or 644
(roof cap)
Model 647
(7” Round wall cap)
Model 407
(7” round duct—2 ft. sections)
Model 410
(10” round duct—2 ft. sections)
MODEL P6 BLOWER/ROUGH-IN KIT
(600 cfm interior blower & rough-in plate)
MODEL P12 BLOWER/ROUGH-IN KIT
(1200 cfm interior blower & rough-in plate)
Model 418
(10” round adjustable elbow)
Model 421
(10” Round Vertical
In-line damper —
Optional)
HL0081
- 4 -
- WP29M SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
In-line and exterior blower rough-in kit (included with EB6, EB9, EB12, EB15, ILB3, ILB6, ILB9 and ILB11 blowers.)
Model 418 10” Round
adjustable elbow
(optional)
Model ILB3 (280 cfm)
in-line blower
(includes one 8” to 10”
round transition)
Model EB6 (600 cfm)
or EB9(900 cfm)
exterior blower
Model EB12 (1200 cfm)
or EB15 (1500 cfm)
exterior blower
Model 441 (10” Round
wall cap)
Model 437
(High capacity roof cap)
Model 441
(10” Round wall cap)
Model 421 (10” Round vert. in-line damper) Recommended for use with exterior blowers
Model 410 (10” Round duct —2ft. sections)
Model ILB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’’ round transitions)
Model ILB9 (800 cfm)
or ILB11 (1100 cfm)
in-line blower
(includes two 8” x 12” to
10’’ round transitions)
WP29M
SERIES HOOD
(Canopy with
blower controls
& lighting.
required for all
installations.)
OPTIONAL DECORATIVE FLUE AEWP SERIES
OPTIONAL
FLAT TOP COVER
ADPWP SERIES
Model 643 (8” Round wall cap)
HL0082