Rangemaster GLX390 User Manual

Page 1
GLX390 Hood
Instructions Manual
www.range master.co.uk
Page 2
EN
Instructions Manual INDEX
RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................3
CHARACTERISTICS..............................................................................................................................................................4
INSTALLATION ......................................................................................................................................................................6
USE.........................................................................................................................................................................................9
MAINTENANCE....................................................................................................................................................................10
2
2
Page 3
EN
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accord-
ingly, you may find descriptions of individual features that do not apply to your specific appliance.
INSTALLATION
• The manufacturer will not be held liable for an y damages resulting fro m incor­rect or impro per installat ion.
• Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the ho od.
• For Class I appliances, check that the domestic power supply guarantees ade­quate earthing.
• Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as shor t as possible.
• Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fi replaces, etc.).
• If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clea n air.
USE
• The extractor hood has been designed exclusively for domestic use to elimi­nate kitchen smells.
• Never use the hood f or purposes ot her than for which it has been designed.
• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
• Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
• Do not flambè under the range hood; risk of fire
• This appliance is not intended for use by persons (including children) with re­duced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for thei r safety.
• Children should be supervised to ensure that they do not play with the appli­ance.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
• Clean and/or replace the Filter s after the specified time p eriod.
• Clean the hood using a damp cloth and a neutral liquid detergent.
The symbol on the product or on its packagin g indicates tha t this product m ay not be treated as hous e hold was te. Ins tea d it s hal l b e ha nde d ov er t o t he a ppli ca ble col lec ti on p oi nt for the recycl ing of elec trical and electr onic equ ipment. B y ensuri ng this pr oduct i s dispose d of correctly, you will help prevent potential negative consequences for the environment and human healt h, which could otherwi se be caused by inappr opriate waste handli ng of this product. For m ore detailed inf ormation about r ecycling of this pr oduct, please c ontact your local city offic e, y our ho use hol d was te di spos al serv ic e or the s hop wher e y ou pur chas ed t h e product.
3
3
Page 4
EN
CHARACTERISTICS
Dimensions
126
81
1270
MIN. 1390 - MAX. 1600
4
4
Page 5
EN
Components
Ref. Q.ty Product Components 1 1 Hood Body, complete with: Contro ls, Light,
Blower, Filters
2.1 1 Up per Section
2.2 1 Lower Sectio n
8 1 Directional Air Outlet grille 9 1 Flange 10 1 Adapting ring ø 120-125 mm
14.1 2 Air Outlet Co nnection Extension
15 1 Air Outlet Connection 16 1 Filter cover Ref. Q.ty Installation Components
7.2.1 2 Upper Chimney Section Fixing Brackets
7.3 1 Air Outlet Connection Supp ort
11 6 Wall Plugs 11a 2 Wall Plugs SB 12/10 12a 6 Sc rews 4,2 x 44,4 12c 10 Screws 2,9 x 6, 5 12d 2 Screws 2,9 x 9,5 Q.ty Documentation
1 Instruction Manual
12a
7.2.1 11
2.1
12c
2.2
7.3
10
9
8
16
12d
15
14.1
12c
11a
1
11
12a
5
5
Page 6
EN
INSTALLATION
Wall drilling and bracket fixing
1÷2
12a
7.2.1
7.3
200
11a
11
112+A
200
1
180
180
2
2
X
1
710+A
A=Min 250
A
Max 400
On the wall, draw
• a Vertical line up to the ceiling or upper limit, at the centre of the area in which the Hood is to be fitted;
• a Horizontal line at a minimum of (710 mm + A) above the Cooker Top.
• Mark a point (1) on the horizontal line, 200 mm to the right of the vertical reference line.
• Repeat this operat ion on the other side, checking that the two marks are level.
• Mark a reference point (2) as indicated at 180 mm from the vertical reference line and (112 mm + A) above the Cooker Top.
• Repeat this operat ion on the other side, checking that the two marks are level.
• Drill at the points (1) marked, using a ø 12 mm drill bit.
• Drill at the points (2) marked, using a ø 8 mm drill bit.
• Insert the bracket plu gs 11a into the holes 1 and screw into pl ace.
• Insert plug 11 into hole 2.
To install a decor ative chimney ( optional )
• Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit align- ing the centre (notch) with the vertical reference line.
• Mark the wall at the cen tres of the holes in the bracket.
• P l ace br acket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line.
• Mark the wall at the centres of the holes in th e br acket.
• Drill ø 8 mm holes at all the centre points marked.
• Insert the wall plugs 11 in the holes.
• Fix the lower bracket 7.2.1 using the 12a screws (4,2 x 44,4) supplied.
• Fix the upper bracket 7.2.1 and the air outlet connection supp ort 7.3 to gether using the 2 screws 12a (4,2 x 44,4) supplied.
6
6
Page 7
EN
Mounting the hood body
• Open the ducting panels.
• Disconnect the panel from the hood canopy by slid­ing the fixing p in lever.(A)
• Remove the metal grease filters by turning the han­dles provided.
• Adjust the two screws Vr, on brackets 11a, to a mini­mum.(B)
• Hook the hood canopy onto the two brackets 11a.
• From inside the hood cano py, ad just the screws Vr to set the Hood Canopy level.
• Tighten the safety screw 11.
Vr
(B)
(A)
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect th e hood to the chimney using either a flexible or rigid pipe ø 150 or 125 mm, the choice of which is left to the installer.
• To install a ø 125 mm air exhaust connection, insert the reducer flange 9 on the hood body air outlet and the adapting ring ø120-125 10 on the reducer flange.
• Fix the pipe in position using sufficient pipe clamps (not supplied).
• Remove any activated charcoal filters.
RECYCLING VERSION AIR OUTLET
To install the hood in recycling version, the optional charcoal filter kit must be purchased.
• Remove the chimney angle bracket.
• Screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5).
• Fix the air outlet grid 8 on the recirculation air outlet using the 2 screws 12d (2,9 x 9,5) provided.
ø 150
9
8
16
ø 125
10
12d
12c
7
7
Page 8
EN
RECIRCULATION VERSION AIR OUTLET
ø 150
15
14.1
7.3
2.1
2.2
2
7.2.1
12c
12c
2.1
2.2
• Insert the connection exten sion pieces lat erall y 14.1 in connec­tion 15.
• Insert th e Connector 15 into the Support bracket 7.3 and fix it with a screw.
• Make sure that th e outlet of the extension pieces 14.1 is hori­zontally and vertically aligned with the chimney outlets.
• Connect the air outlet co nnection 15 to the hood body outlet using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer.
• Ensure that the activated charcoal filters have been inserted.
Chimney assembly
Upper exhaust Chimney
• Slightly widen the two sides of the upper chimney and hook them behind the brackets 7.2.1, making sure that they are well seated.
• Secure the si des to the brackets u sing the 4 screws 12c (2,9 x 9,5) supplied.
Lower exhaust Chimney
• Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall, making sure that they are well seated.
• Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav­ing a contact gap of at least 3 mm.
• Re move the grease filters (see paragraph Maintenance) being sure that the conn ector of the feeding cable is correctly inserted in the socket placed on th e side of the fan.
8
8
Page 9
EN
USE
Control Panel
The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.
KEY LED FUNCTIONS L 0/1 Light Turns lighting on and off.
T1 0/1 Motor on First speed.
When pressed for about 1 seconds the motor is switched off.
Flashing 24h Changeover This is enabled by pressing and holding
the button for approximately 5".It al­lows a suction level of 100 m3/h with a noise level of just 28dB(A).Can be en­abled at any speed, even with the hood turned off.To disable, press and hold the button for appro xi mately 5".
T2 Speed on Second speed. Flashing Delay (30') Press the button for approximately 2" to enable auto-
matic shutdown with a 30' delay. Suitable to complete elimination of any residual smells. Can be enabled at any speed and is disabled by pressing the button T1 briefly.
T3 Speed on Third speed. T4 Speed Fixed Max. speed
Flashing Intensive speed. Suitable for the strongest cooking vapours and odours.
The function becomes active when the button is pushed for about 2 seconds. After 10 minutes of func­tioning it turns off automatically. This function can be interrupted by means of pressing any of the buttons.
S1 Led Fixed Indicates that the Metal grease filters saturat ion alarm
has been triggered, and the filters need to be washed. The alarm is triggered after 100 working hours. (Re-
set; check the Maint enance-paragraph)
Flashing indicates that the activated charcoal odour filter
saturation alarm has been triggered, and the filter has to be replaced; the metal grease filters must also be washed. The activated charcoal odour filter is triggered after 200 working hours. (Activation and Reset; check the Main tenance-paragraph)
L
T1
T2
T3
T4
S1
9
9
Page 10
EN 110
MAINTENANCE
REMOTE CONTROL (OPTIONAL)
The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03­AAA type.
• Do not place the remote control near to heat sources.
• Used batteries must be disposed of in the proper manner.
Ducting panels
• Open the ducting panels.
• Disconnect the panel from the hood canopy by sliding the fix­ing pin lever.
• Clean the outside using a damp cloth and neutral liquid deter­gent.
• Clean the inside using a damp cloth and neutral detergent; do not use wet cloths or sponges, or jets of water; do not use abra­sive substances.
Page 11
EN 111
Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
Alarm signal reset
• Switch off the lights and extractor motor.
• P ress bu tton T3 for at least 3 seconds, until the leds start to flash.
Cleaning the filters
• The filters are washable and must be cleaned when the LED S1 lights up or at least every 2 months of operation, or more fre­quently for particularly heavy usage.
• Remove the filters one at a time holding them up with one hand and pulling the handle downwards with the other hand at the same time.
• Wash the filters, taking care not to bend them. Allow them to dry before refitting.
• When refitting the filters, make sure that the handle is visible on the outside.
Page 12
EN 112
Activated charcoal filter (Recirculation version)
A
B
The filter is not washable and cannot be regenerated. It must be replaced when led S1 fl ashe s or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.
• Restore the connection by pressing and holding T1.
• Release the button. All five LEDs are turned on.
Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
- LED flashes twice - Activated charcoal filter saturation alarm ENABLED.
- LED flashes once - Activated charcoal filter saturation alarm DISABLED.
REPLACING THE ACTIVATED CHARCOAL FILTE R
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds start to
flash.
Replacing the Filter
• Remove the metal grease filters
• Remove the saturated activated carbon filters as shown (A).
• Fit the new filters (B).
• Replace the metal grease filters.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the light cover by unfastening the screws that hold it.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
• Replace the light cover.
Page 13
Page 14
Page 15
Page 16
436004184_ver1