9580-2A 9580-3A 9580-4A 9580-5A 9580-6A
Description:
Drop-in self-contained, cold pan / heated food well unit. With the flip of a switch, this unit is converted from a hot breakfast buffet to a cold salad bar for lunch, or any other use. One piece stainless steel top and coved corner interior. Controls, cordset & louver panel provided. True thermostatic control for hot operation. R-404a refrigeration system is “CFC free”.
Specifications:
UNIT TOP: Top and water bath tank to be one piece, 16 gauge stainless steel.
UNIT BODY: Fully insulated, exterior body to be corrosion resistant steel. Unit sidewalls feature wrapped refrigeration lines with foamed in place polyurethane insulation, unit bottom fitted with heating elements, fiberglass insulation and shield. Interior fitted with 1" drain at one end. Drain nipple supplied with gate valve. 1" high perforated stainless steel bottom strainer plate(s) provided for cold pan use. Condensing unit mounted on corrosion resistant framework, suspended below unit body.
CONTROLS: Controls prewired to junction box mounted on separate stainless steel panel for field installation in counter front. Connections to heating elements to be located outside of heated zone to avoid wiring deterioration. Hard wire connection required for hot food well operation.
• The same unit can now be used for hot or cold food applications
Standard Features: COLD USE
• All stainless steel top
• Drain & gate valve standard (Note: gate valve shipped loose for field installation by others)
• Stainless, perforated bottom strainer plates provided
• Wrapped, coldwall construction refrigeration
• Stainless steel louver panel provided
• R-404a refrigerant, “CFC free”
model 9580-3A shown
Standard Features: HOT USE
• All stainless steel top
• Open tank Baine Marie style for wet operation
• True thermostatic control for precise food temperatures
• Drain and gate valve
Options & Accessories:
Adaptor bars Remote on/off switch Extended thermostatic lead
1055 Mendell Davis Drive, Jackson, MS 39272 888-994-7636, unifiedbrands.net
Please reference our website for the most updated product information and specifications.
For use with ice. Provided with cooling system to reduce ice usage.
Randell Drop-In, Page 5
PP SPEC0061 Rev. C
Revised 08/12
REQUIRES HARDWIRE CONNECTION
D
LEGEND FOR
1" DIA DRAIN LINE CONNECTION
120/208V-60Hz-1Ph 21.2Amps
120/240V-60Hz-1Ph 18.3Amps
MODEL # 9580-5A
(4) ELEMENT, 4400 WATTS
1/4hp COMPRESSOR
1" FPT AT 24" AFF
REQUIRES HARDWIRE CONNECTION
D
MODEL # 9580-4A
LEGEND FOR
120/240V-60Hz-1Ph 13.3Amps
120/208V-60Hz-1Ph 15.9Amps
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
1/4hp COMPRESSOR
(3) ELEMENTS, 3300 WATTS
6"
6"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-5A
CUTOUT DIMENSION
65.75" X 22.5"
69.25"
63.25"
20"
9"
18.25"
22"
26"
27.25"
65.25"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-4A
CUTOUT DIMENSION
53" X 22.5"
56.5"
50.5"
20"
9"
18.25"
22"
26"
27.25"
52.5"
1" HIGH PERFORATED S/S BOTTOM
Models 9580A
REQUIRES HARDWIRE CONNECTION
D
LEGEND FOR
1" DIA DRAIN LINE CONNECTION
120/208V-60Hz-1Ph 21.2Amps
120/240V-60Hz-1Ph 18.3Amps
MODEL # 9580-5A
(4) ELEMENT, 4400 WATTS
1/4hp COMPRESSOR
1" FPT AT 24" AFF
6"
MODEL #9580-5A
CUTOUT DIMENSION
65.75" X 22.5"
69.25"
63.25"
20"
9"
18.25"
22"
26"
27.25"
65.25"
REQUIRES HARDWIRE CONNECTION
D
LEGEND FOR
1" DIA DRAIN LINE CONNECTION
120/208V-60Hz-1Ph 21.2Amps
120/240V-60Hz-1Ph 18.3Amps
MODEL # 9580-5A
(4) ELEMENT, 4400 WATTS
1/4hp COMPRESSOR
1" FPT AT 24" AFF
REQUIRES HARDWIRE CONNECTION
D
MODEL # 9580-4A
LEGEND FOR
120/240V-60Hz-1Ph 13.3Amps
120/208V-60Hz-1Ph 15.9Amps
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
1/4hp COMPRESSOR
(3) ELEMENTS, 3300 WATTS
120/208V-60Hz-1Ph 10.6Amps
120/240V-60Hz-1Ph 9.2Amps
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
1/4hp COMPRESSOR
(2) ELEMENTS, 2200 WATTS
REQUIRES HARDWIRE CONNECTION
D
MODEL # 9580-3A
LEGEND FOR
(1) ELEMENT, 1100 WATTS
REQUIRES HARDWIRE CONNECTION
1/4hp COMPRESSOR
120/208V-60Hz-1Ph 5.3Amps
120/240V-60Hz-1Ph 4.5Amps
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
MODEL # 9580-2A
D
LEGEND FOR
6"
6"
6"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-5A
CUTOUT DIMENSION
65.75" X 22.5"
69.25"
63.25"
20"
9"
18.25"
22"
26"
27.25"
65.25"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-4A
CUTOUT DIMENSION
53" X 22.5"
56.5"
50.5"
20"
9"
18.25"
22"
26"
27.25"
52.5"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-3A
CUTOUT DIMENSION
40.25" X 22.5"
39.75"
37.75"
43.75"
20"
9"
18.25"
22"
26"
27.25"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-2A
CUTOUT DIMENSION
27.75" X 22.5"
25.25"
27.25"
31.25"
20"
22"
26"
18.25"
9"
6"
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 5.3Amps
120/240V-60Hz-1Ph 4.5Amps
1" DIA DRAIN LINE CONNECTION
D
1" FPT AT 24" AFF
MODEL #9580-2A
LEGEND FOR
MODEL # 9580-2A
(1) ELEMENT, 1100 WATTS
1/4hp COMPRESSOR
20"
22"
26"
CUTOUT DIMENSION
27.75" X 22.5"
25.25"
27.25"
31.25"
6"
9"
18.25"
1" HIGH PERFORATED S/S BOTTOM
LEGEND FOR
MODEL # 9580-3A
(2) ELEMENTS, 2200 WATTS
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 10.6Amps
120/240V-60Hz-1Ph 9.2Amps
1/4hp COMPRESSOR
1" DIA DRAIN LINE CONNECTION
D
1" FPT AT 24" AFF
20"
22"
26"
CUTOUT DIMENSION
40.25" X 22.5"
37.75"
27.25"
39.75"
43.75"
MODEL #9580-3A
LEGEND FOR
MODEL # 9580-4A
(3) ELEMENTS, 3300 WATTS
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 15.9Amps
120/240V-60Hz-1Ph 13.3Amps
1/4hp COMPRESSOR
1" DIA DRAIN LINE CONNECTION
D
1" FPT AT 24" AFF
20"
9"
6"
18.25"
9"
6"
18.25"
22"
26"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-4A
CUTOUT DIMENSION
53" X 22.5"
27.25"
56.5"
50.5"
52.5"
1" HIGH PERFORATED S/S BOTTOM
LEGEND FOR
MODEL # 9580-5A
(4) ELEMENT, 4400 WATTS
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 21.2Amps
120/240V-60Hz-1Ph 18.3Amps
1/4hp COMPRESSOR
1" DIA DRAIN LINE CONNECTION
D
1" FPT AT 24" AFF
20"
22"
26"
27.25"
MODEL #9580-5A
9"
6"
18.25"
CUTOUT DIMENSION
65.75" X 22.5"
63.25"
65.25"
69.25"
1" HIGH PERFORATED S/S BOTTOM
MODEL #9580-6A
20"
22"
26"
6"
9"
18.25"
CUTOUT DIMENSION
78.5" X 22.5"
HP
J
D
12"x20" Cut Out Size No. of Amps / 60 / 1 PH Model L D Pan Cap. Unit Control Panel Elements Watts H.P. 120V (Refrig.) 208V (Heated) 240V (Heated) Ship Wt.
9580-2A 31 1/8" 26" 2 27 3/4" x 22 1/2" 14” x 6” 1 1100 1/4 5.3 5.3 4.5 110
9580-3A 43 5/8" 26" 3 40 1/4" x 22 1/2" 14” x 6” 2 2200 1/4 5.3 10.6 9.2 135
9580-4A 56 1/2" 26" 4 53" x 22 1/2" 14” x 6” 3 3300 1/4 5.3 15.9 13.8 160
9580-5A 69 1/4" 26" 5 65 3/4" x 22 1/2" 14” x 6” 4 4400 1/4 5.3 21.2 18.3 185
9580-6A 82” 26” 6 78 1/2” x 22 1/2” 14” x 6” 5 5500 1/4 5.3 31.4 27.9 210
Requires 120 / 240V or 120/208V (4 wire) power supply hard wiring to “J” box. 120V refrigeration system - 208/240V heating system.