1 Precautions
1.Transportation Security
No heavy stress, violent vibration or water splash are allowed during transportation,storage.The unit should be transported in separated packing.In shipments of distributor and delivery of maintenance,any damages caused by integral packing are not covered by warranty.
2.Installation
Avoid heavy stress and violent vibration during installation. Don’t touch the dome cover directly by hand. When connecting the power source, please follow all electric safety standards and only use the power supply designated for this device. Keep the video and control signal in a decent distance from high voltage devices and cable. Don’t
3.Internal Environment
entering the dome. If occur this, please shut down the power and pull out the plug. Then inform the technical personnel immediately.
4.Electrical Safety
The video image would be interfered when the dome is installed near
5.Camera Protection
Avoid shooting very bright objects directly into the camera’s CCD (such
6.Cleaning Method
Please don’t use abrasive and violent detergent to clean the dome. Please choose dry fabric and neutral detergent. Use lens paper to clean the lens.
1
2 Features
2.1 Built-in Decoder
r
2
Presets calling speed :350 /S
2.5 Function Instructions
3
Focus / Pan / Tilt Speed Auto Match
Auto Flip
The lens can auto flip when it rotates 180°
Preset Position Setting and Calling
Preset function means the speed dome can memory current pan/tilt angel, focus, zoom, ect. When need, it can be called upon directly. Our speed dome support up to 220 preset positions.
Auto Scan
Users can set the left and right boundaries by control keyboard. Then speed dome can scan between it. It can set up to 8 groups scan path.
Pattern Tour
Speed Dome can memory 180s running path or 500 orders. When start pattern tour, speed dome can track as recording path. It supports 4 groups pattern tour.
Guard Location
The dome will rotate back to preset position after a period of vacant time.
Privacy Protection Function
Set black areas to mask the privacy or security parts. The black areas location­can be set, and support up to 8 mask zones.
Timing Running Function
Users can set speed dome operation task at different time during one week.
Motion Detection Function
For some special cameras, the dome can auto track the moving things.
3D Location Function In dome effective zoom scope, can zoom in and out any area on screen, also can move any point to center.
Auto Tracking Function IR speed dome can automatically ock and tacking the moving object according to the parameters setup .
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
The pan/tilt rotation speed could be auto adjusted according to the focus in/out, which makes it great performance for manual target tracking.
4
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Zoom Control Users can control zoom by keyboard to get near or far images.
Auto Iris Control Auto sense ambient light, and make quick adjustments.
Auto Back Compensation In the bright background, auto compensate light for the target, and adjust the back light.
Auto/Manual White Balance Auto/Manual adjust depending on the environment light changes.
Day and Night Switch (Only for Day/Nigh Camera) Speed dome camera can auto switch between color and black and white.
High Speed Dome Menu Setup (Only for camera with menu) Call upon preset No.95 to enter into menu setup interface. Press “Focus” to choose menu items and press “Iris” to set menu contents.
Alarm Function It supports 4-channel alarm input and 2-channel alarm output .
Lens Control
3 Technical Data
PowerPower Supply
Operating Temperature
Operating moisture
Power Consumption
Communication
Communication transmission speed
Protocols
Pan speed
Titlt Angle
Pan/Tilt Accuracy
Preset Speed
Pan Angle
Auto Filp
Preset Positions
Auto Scan
Cruise Track
Cruise Points Qty per cruise group
Pattern Tours
Alarm
Privacy Zone
Protection
DC12V & 5A
Indoor˖050§Outdoor˖-3560ć
< 95%
Indoor˖15W Outdoor˖55W
RS-485 bus
2400/4800/9600BPS
Pelco-D, Pelco-P,HS
0.01°-180° /s
0 -90°
+/- 0.05°
350°/s
360° Continuously
auto flip 180° when tilt angle is 90 °
220
8 Groups
8 Groups
32 Preset Positions
4 Groups
4 alarm inputs and 2 outputs
8 zones
IP66 water proof/3000V lightning proof
5
4 Installation Guide
4.1 Installation Preparation
Video Coaxial Cables
4.2 Structure
4.3 Installation Size
Mode
RG59/U
RG6/U
RG11/U
Max Distance
750ft(229m)
1,000ft(305m)
1,500ft(457m)
6
4.4 Installation Procedures
*Notice: The wall must be thick enough to install the expansion
screws and can bear 4 times the weight of the dome camera itself.
(1) Bore 4 holes by using templates included on the wall.
(2) Mount 4 M8 expansion screws into the holes
7
(3) Put the cables through the bracket. Fix the dome base and the
bracket with M5 screws.
8
(4) Use screw-caps and shims to fix the bracket on the wall.
5 Dome Setting
Protocol Setting
Transmission Speed Setting
9
Before the dome is installed,the communication protocol, baud rate and dome address, should be confirmed.Set the DIP switch, keeping the setting consistent with the control system. The relative DIP switch site and connecting wires are diagramed below for reference.
SW1 is address setting switch,SW2 is protocol setting switch.
ON
DIP
ON
DIP
Protocol SW2-1 SW2-2 SW2-3 SW2-4
HS OFF OFF OFF OFF
PELCO P ON OFF OFF OFF
PELCO D OFF ON OFF OFF
Reserve ... ... ... ...
Baud Rate
9600
4800
2400
Reserve
SW2-5
OFF
ON
OFF
...
SW2-6
OFF
OFF
ON
...
Dome Address Setting
10
PELCO-P & HS protocol
Address
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
...
254
255
SW1-1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
...
1
0
SW1-2
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
...
0
1
SW1-3
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
...
1
1
SW1-4
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
...
1
1
SW1-5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
...
1
1
SW1-6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
...
1
1
SW1-7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
...
1
1
SW1-8
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
...
1
1
PELCO-D protocol
11
Address
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
...
253
254
SW1-1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
...
1
0
SW1-2
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
...
0
1
SW1-3
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
...
1
1
SW1-4
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
...
1
1
SW1-5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
...
1
1
SW1-6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
...
1
1
SW1-7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
...
1
1
SW1-8
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
...
1
1
Cable Definition
12
Loading...
+ 31 hidden pages