Before using your air-conditioner, please read this operating instruction carefully and keep it for future reference.
This appliance is not intended for use by persons (including children) with reduced physica
l,
sensory or mental capabilities
,or
of
experience and knowledge, unless they have
been given supervision
or
instruction concerning use
of
the
appliance by a person responsible for
their
safety.
Children
should
be
supervised to ensure that they do not play
with the appliance.
- 2-
PRECAUTIONS
&,
Danger
This sign warns of death or serious injury. 1 )Do not attempt to
install this
air
conditioner by yourself.
2)This unit contains no user-serviceab le parts .Always consult authorized service personnel for repairs.
3)When moving, consult authorized service personne l
for
disconnection and installation
of
the unit.
4 )Do not become excessively
chilled by staying
for
lengthy
periods
in
the direct cooling airflow.
5 )Do not insert fingers or objects into the
outlet port or
intake
grilles.
6)Do not start and stop
air
conditioner operation by
disconnecting the power
supply cord and so on.
?)Take care not to damage the power
supply cord.
8)The appliance is fitted with means
for
disconnection from
the
supply mains having a contact separation
in
all poles that
provide
full disconnection under over voltage category Ill
conditions, and these means must
be
incorporated
in
the fixed
wiring
in
accordance with the wiring rules.
&,
Caution
This sign warns
of
damage to property.
1)
Provide occasional ventilation during use .
2) Do not direct
air
flow at fireplaces or heating apparatus . '
3) Do not
climb on,
or
place objects on the
air
conditioner.
4) Do not hang objects from the
indoor
unit .
5) Do not set
flower
vases or water containers on top
of
air
conditioners.
6) Do not expose the
air
conditioner directly to water.
7)
Do
not pull power supply cord.
-
3-
8)Turn off power source when not using the unit for extended periods.
9)Check the condition
of
the installation stand for damage.
1
O)Do
not place animals
or
plants
in
the direct path
of
the
air
flow.
11
)Do not drink the water drained from the
air
conditioner.
12)Do not use
in
applications involving the storage of foods
,plants or animals , precision equipment, or
art
works.
13)Connection
valves become hot during Heating,handle with
care.
14)Do not
apply any heavy pressure to radiator fins .
15)0perate
only with air filters installed.
16)Do not block or cover the intake grille and outlet port.
17)Ensure that any
electronic equipment is
at
least one
metre away from either the indoor
or
outdoor units .
18)Avoid
installing the air conditioner near a fireplace or
other heating apparatus.
19)When
installing the indoor and outdoor unit ,take
precautions to prevent access to infants.
20)Do not use
inflammable gases near the
air
conditioner.
-
4-
NAME
OF
EACH
PART
Features and appearance will vary. A
ll
the figures give a
demonstration to introduce the funtion.
Removes
dust
or
dirt oul
or
the inl
et
air
Different model positions are different.
11----~
Refrigerant
pip
ing
connection
,
Electric
wiring
cord
-
5-
USE
OF
REMOTE
CONTROLLER
Attention:
1.
The
appearances
of
the
follow
ing
remote
controllers
will
vary,but
the
functions
of
the
same
button
are
same,
Please
check
to
refer
the
ins
tructions
for the identical remote controll
er of
you
r ai
r-cond
iti
oner
.
2.
The
remote
con
troller 1 and
remote
controller 2 are the
general
one
used
for
many
types
of a
ir-condi
tion
er
In
our
company,
we
beg
your
forgiveness
that
we
would not introduce
the
button
or
indicator whi
ch
Is
not
applicab
le
for units you
purchased
.
The "LAMP"
and 'CLEAN"
button
are
appl
icab
le
for
special
latest
developed
new
models
only
instead
of
normal
models
.
The
'AIR
FLOW"
button
is
an
optiona
l funct
ion
button,it
just
works
on
those
models
with three-dimensional
air
flow
funct
ion.
Remote
Controller
1
Temper
ature
indicator
I
ndicates the
set
temperature
.
AUTO
indicator
COO
LING indicator
DRYI
NG
indicator
(
HEATING
indi
cator
FANING
indicator
SWING ind
icator
Indicates
selected
flap
mode.
TIME
indicator
In
dicates timer
time.
Indicates
during
TURBO
operation.
Key
lock
indicator
FAN
SPEED
ind
icator
Indicates the seted air
rate.
ON/OFF
button
This
button,
wt.m
pressed
starts
operation
SET
TEMPERATURE button
and
stops
when
repressed.
C
=T=h=is=oo}tt~on~s~e[
t
s~th~e~room~
=
te=m~p=era=t
=u
r=e.
)-
t-
~=s~:---;:==::;;;;::+-1--<
swt
NG
button
MODE
button
This
button
changes
the
flap
mode:natural
This
button
changes
the
operation
mode:
AUT
O,COOL,DRY,
HEA T ,FAN
.
(
FAN SPEED
button
This
button set
air
rate.
TURBO butto
n
This
button
changes
to
TURBO
operation
(It
does
not
work
in
AUTO,DRY,and FAN
mode
.)
( TI
MER
button
)
--4------'
This
button
is
used
to
set
the
switch-()n
or
s
witch-()ff
and
the
timer
time.
NOTE
:
flow ,sw
ing
or
fiXed
wind.
AIR
FLO
W b
utt
on(
optiona
l)
This
button
used
for
selection
of
lhe lefllright
a
ir
flow
direction, when
ever pressed the
in
flap
will
swing
or
fix(lt
just wor1<s
on
three-
dimensional air
flow
model.)
SLEEP
button
This
button
changes
to
SLEEP
operation.
HOLD
button
Press
this
button to
lock
or
unlock
the
keyboard.
0
Above
f19ure
shows
all
indications
for
the
purpose
of
explanation,
but
practically
only the
pertinent
parts
are
Indicated
.Wh
en
air-conditioner
is
cooling-only
model,
the
HEATis
for
FAN.
0
When
TUR
BO operation
is
selected,room
temperature
is
not
controlled
with
operation being
continually
.lf
you
feel
the
room
temperature
is
too
cool
or
too heat,
please
cancel
the
TURBO
operation.
- 6-
Remote
Controller
2
Te
mpe
rature
indicator
Indicates
the
set
temperature
.
OPERATION
MODE
indicator
ind
icates
selected
operation
mode
TIME indicator
Indicates
timer
time
.
OPERATION
MODE select
button
Th
is button cha
nges
the
operation
mode:
AUTO,COOL,DRY,HEAT,FAN.
ON/OFF button
This
button, when
pressed
starts
operation
and
stops
when repressed
.
(
FAN
SPEED
button
Th
is bu
tton set air rate
.
TIMER
butto
n
This
button
is
used
to
set
the
switch-(10
or
swi
tch-off
and
lhe
timer
~me.
('":
__
T.:...:U:.:.R:.:.B..::.O...:b:.:.
UI:.::IO::.:.n __
_..
)
-+---'
This
button
changes
to
TURBO
operation
(It
does not
work
in
AUTO
,DR
Y,a
nd
FAN
mode.
)
NOTE:
FAN SPEED indicator
Indicates
the
seted air
rate
.
SLE
EP
indica
tor
Indicates
during
sleep
opera
tion.
TURBO
indica
tor
Indicates
duri
ng TU
RBO
operation.
SWING indicator
I
ndicates
selected flap
mode.
Key
lock
indicator
~...-::t:.....-+-t-(SETT
E
MPERATURE
bu
tto
n )
Th
is
button
sets
the
room temperatur
e.
SWING
button
This
button
changes
the
flap
mode:natural
flow,swing
or
fixed wind.
AIR
FLOW
button( optional)
This
but
ton
used
tor
selection
of
the
lefVrigh
t
air
flow
direction,
whenever pr
essed the
in
flap will
swing
or
fix(
It just
works
on
three·
d•mensional
air
flow
model.)
SLEEP
button
This button
changes
to
SLE
EP
operation
.
HO
LD
button
Press
thi
s b
utton to loc
k or unl
ock
the
keyb
oAr
d.
0
Abo
ve
figure
shows
all
indications
for
the purpose
of
explanation,
but
practically
only
the pertinent parts
are
indica
ted
.Wh
en
air-condi
tion
er
is
cooling-only
model,
the
HEATis
for
FAN.
0
When
TURBO
operation
is
selected,room
temperature
is
not
controlled
with
operation
being
continually.
lf
you fee
l the
room
temperat
ure is
too
coo
l or
too
heat
, pl
ease
cancel
the TU
RBO
operat
ion.
Remote
Controller
3
Attention
:
T
his
remote
controller
is
the
general one
used
for
many
types
of air-conditioner
in
our
company,
we
beg
your forgiveness
th
at
we would
not introduce
the button or
indicator which
is
not
applicab
le
for
units
you
pur
chased.
The
LAMP button"
1f!'-',
CLEAN
button"~
·are
applicab
le
for
special
latest
developed
new
mode
ls
only instead
of
normal models. The
"AIR FLOW"
button
is
an
optional function button
, it j
ust
works
on
those
models
with three-dimensional air
flow
function
.
Au
to
operation
indicator
SET
TEMPERATURE button
This button
sets
the
room
temperature.
SWING
button
This
button
changes
the
up/down
ftap
mode:
natural flow,swing
or
fixed wind
.
AIR
FLOW button( optiona
l)
This button
used
for
selection
of
the
left/right
air
flow direction,whenever
pressed
the
in
fla
p
will swi
ng
or fix(lt just works
on
three-
dimensiona
l air
now
model.)
TI
MER
button
Th
is
button
is
used
to set
the
switch·on
or
switch-on
and
the
timer
time.
SLEEP butto
n
Th
is
bullon
changes
to
SLE
EP
operation.
NOTE
:
HOL
D b
utt
on
OPERATION
MODE select butt
on
This
button
changes
the
operation
mode
:
AUTO,COOL,DRY,HEAT.FA
N.
FAN
SPEED
button
T
his
butt
on
set air
rate.
TURBO
button
This button
changes
to
TURBO
operation.
(It
does
not
work
In
AUTO,DRY,and
FAN
mode.)
P
ress
this
button
to
1ocl<
or
unlock
the
keyboard.
0
Above
figure
shows
all ind
icatio
ns
for
the
purpose of
explanation,
but
practically only
the
pertine
nt parts
are
indicated
.When
air-conditioner
is
cooling-only
mode
l,
the
HEATis
for
FAN
.
0
When TURBO
ope
rat
ion
is
selecled,room
temperatu
re
is
not
controlled
with ope
ration
being
continually.
lf
you
feel the
room
temperatu
re
is
too cool
or
too
heat,please cancel
the TURBO
operation
.
-8-
Remote
Controller
4
Te
mperature
indicator
I
ndicates
the
set
temperature.
OPERATION
MODE
indicator
i
ndica
tes sel
ected
operation
mode
T
IME
indicato
r
Indicates
timer
time
.
F
AN
SPE
ED
indicator
I
ndicates
the
seted
air rate.
SLEE
P i
ndicator
I
ndicates
during sleep
operation.
TURBO Indicator
I
ndicates
during
TURBO
operation.
SWING
indicato
r
Indi
cates
selected
nap
mode.
Key
lock
indicator
C
ON/OFF
button
-+--~-r---;;--;
~--~~~
~~-+~~~~~
Th
is
button,
when
pressed
sta
rts
operation
£ SET T
EMPERATURE
button
and stops
When
repressed.
This
button
sets the
room
temperature.
(OPERATION
MODE select
button)
--,--'-----'
This
button
changes
the
operation
mode:
AUTO,COOL,DRY,H
EAT,FAN.
(
FAN SPEED butt
on
This
button
set
air
rate.
TURBO button
Th
is
button
changes
to
TURBO
operation
(tt
does net
work
In
AUTO,DRY,and
FAN
mode.)
HOLD button
Press
this
button
to
lock
or
unlock
the
keyboard.
NOTE:
SLEEP
button
This butt
on
changes
to
SLEEP
operation.
TI
MER button
This
button
is u
sed
to
set
the
switch-on
or
swi
tch-off
and
the
timer
time.
SW
ING
button
Th
is
button
changes
the
flap
mode:natural
now,swing
or
fixed
wind.
0
Above
figure
shows all indications
for
the
purpose
of
explanation,
but
pra
ctically
only
the
pertinent parts
are indicated. When
air-conditioner
is
cooling-only
model
, t
he
HEATis for
FAN
.
0
When TURBO
operation
is sel
ected,room
temperature
is not
controlle
d with
operation being
continually.lf
you
feel
the
room temperature
is
too
coo
l or
too
heat,please
cancel the
TURBO
operation
.
-9-
e
OPERATING
MACHINE
IN
SELECTED
MODES
1.
Point the
remo
te
controller at
the unit
,press the
ON/OFF
button,
then press
the
MODE
button,select the n
eeded
mode: ATU
O,COOL,DRY,HEAT,or
FAN
.
2.
Press
the
SET
TEMPERATURE
button
to
increase
or
decrease
the
readings until the ne
eded tem
peraure
is
displayed. The r
oom
set
temp
era
ture
range
is
from 16'
C-32'C(61'F-90'F).
(It wou
ld
be
automatically
set
at 25'C
(76'
F) and
unadjustable
in
AUTO
and
DYR
mode.)
3.
Press
the
FAN SPEED
button
to
choose
the
air
rate
you
want:
Low(
display
indicates" '""
),Med(display
ind
icates
"
,..
",Hi(display indicates
" • d
",A
uto(
display"
~I
"
indi
cator
flas
hin
g).
(It
wou
ld
be
automatically
set all
ow
speed and una
djustable
in
DRY
mode.)
4.
Press
the
SWING
button
to
choose
the up/dow
n air
flow
direction
you
want:natural
flow( display i
ndicates
" (
"),swing( display" ( •
indicator
flashin
g)
,fixed
wind( dis
play
indicates
• :
").
(It
wou
ld
be
automatically
set
at
fixed wind
air
flow
direction
in
DRY
mode.)
e TURBO
OPERATION
Press
TURBO button
during
COOL or
HEAT
operation,the
air
rate
can
be
setted
in
HIGH
.Press
the
TURBO
button
again
can
release
the
TURBO
operat
ion.
N
ole:
duri
ng
TURBO
operation,the
air
rate
cann't
be
changed.
eADJUSTING
LEFT/RIGHT
AIR
FLOW
Methods
1 :
Manually
adjust
Adjust
the
direction by
moving
direclly
the lefVright
air
flow.direction
adjusting
fin
by hand.
Caution:when adjust
the
direction,sto
p a
ir
conditioner.
Methods
2:Horlzontal & vertical
auto
swing(three-dimenslonal
air flow
model)
Ad
just
the
direction
by
remote
contro
ller.Press
the AIR FLOW
button,t
he
air
swinging
fins will
constantly
make
the
lefVright
swinging
or
fixed
direction
in
air
delivery.
e TIMER OPERA T/ON
Set turning
off
time
Set the
time for the
unit
to
turn
off a
nd when
it
is
time,t
he
air
conditioner
will a
utomat
ically
stop
operating.
1.
During the
operation
of
the
air
conditioner,
press
the
TIMER button
and
the
air
conditioner
will ent
er the timed
switch-off
mode.
2.
Continuely press
the
TIMER
button
to
set
the
needed
time
for
switching
off
the
machine.
The
timer
can
make
the
setting
in
the
range from 1-24 hours.Every
the
button
is
pressed,indicat
ion
change
is
the following
sequence:
1 - 2 -
........ -24 -cancel
(no
indication)-
1.
3.
After
the
setting
of
the
timed swit
ch-off, the
digits
shown
on
the
display
screen
w~l
go
down
by 1 for every
elapsed
hour.
The
displayed digits in
dicate
the remaining
time
prior
to
the
timed
switch-off.
Set turning on time
Set the time
for the
unit
to
turn
on a
nd
when
it
is
time,
the air
conditioner
will
automatica
lly
start operating.
1.
When the
air
conditioner
is in
the standby
mode, press the TIM
ER
button
and
the
air
conditioner
will
enter
the
timed
switch-on
mode.
2.Cont
inue
ly press the
TIMER
button
to
set the nee
ded
time
for
switching
on the machine. The
timer
can
make
the setting
in the
range from
1-24
hours.Every
the button
is
pressed,indication change
is
the
following
sequence
:
1 - 2 -
........ -24 -cancel
(no
ind
ica
tion)-
1.
3.
After
the
setting
of
the
timed
switch-on, the digits
shown
on
the
display
screen
will
go down
by 1 for
every
elapsed
hour. The
displayed digits
indicate
the
remaini
ng time
prior
to
the
timed
swi
tch-on.
-10-
,,
Releasing procedure
Wh
en the
ind
ication on display
scree
n is
24
hour,press
the TI
MER
button
again
to
delete
the ti
med mode
.
e
SLEEP
OPERATION
Use
this
mode
to
red
uce operation
sound
when
sleeping,etc.
Press the SLEEP butt
on,t
he
air
flow sou
nd
fro
m t
he indoor
uni
t is
dec
rea
sed
.
Press the SLEEP butt
on
again can
rele
ase
the
mode
.
NOTE:
Use
the
sleep
mode
when you
are going
to
bed.
If this
mode
is
used
in
the
day,the
capacity
is
red
uced since the
ambient
temperature
is
too
high.
(COOL
MODE).
During
the
operation
of
cooling,the room
temperature
will
be
raised
gradually
by 2"C(4'Fl hi
gher tha
n t
he
setting
after
the
machine
begins
to
operate
in
the
slee
ping mode.
During
the
operation
of
heating mode,the
room
temperature will
be
dropped
gradually 5'C (9'F)
Iower than
the
setting
after the machine begins
to operate
in the sleeping
mode.
e
REPLACEMENT
OF
BATTERIES
When
the signal from
the
remote
controller
becomes
weak and
the
i
ndoor
uni
t c
an not
receive
it
properly;or
the
indications
on
the
display
sc
reen
becomes
blurred,please slid
e t
he
back
cover
and
replace with
two
new
batteries.
The
pos
iti
ve
and
negati
ve
poles mus
t mat
ch the installat
ion
pos
iti
ons
.
New batteries of the
same
type
have
to
be used for
repl
acement.
• If t
he
remote
controller
is
not
to
be
used for long t
ime,
take out the
batteries
so
as
to
prevent
the leakage
of
the
electrolyte
from
damaging
the con
troller.
• If w
hen
the
remote
controller
is
at
abnormal sta
te,
you
can
take
out
the batteries
on
the
back
cover
to
clear
off
the display
.
-1
1-
Remo
te
Controller
2,4
Un
load
the
back
Ower
Remote
Controller
1,3
Remote
Controller
5
(Set
tempera
ture
indicato
r )
,---{
SLEEP
indicator
)
I
ndicates
during
SLEEP
operation.
(
AU
TO indicator
rl
ECONO indicator
)
(
COOLI
NG in
dicator
I
ndicates
during
ECONOMY
opera
tlon.
~
rt'n
'F
.,
HI
POWER
ind
ica
tor
(
DRYING
indica
tor
I'
Ind
icates
during
HI
POWER
oper
,;;
OO
·c
(
HEATI
NG
indica
tor
)
{5
Swing
indicator
~
-0
(
FANI
NG
indicator
\
;;:.
••••
\..
FAN
SPEED
indicator
'B:ae
0
ON
::1
I
(
PRESENT
TIME
indica
tor
0
OI'F
I)(I
H
)
TIMER
TIM
E i
ndi
cator
ation.
12
'f
(SET TEMPERATURE
button
(
ONJOF
F bu
tton
)
0
This
button
set
the
room
temperature.
-
This
button,
YAlen
pressed
starts
ope
ration
(
RESET button
~
and
stops
when
repressed
.
---
L
CLOCK
SETTING
button)
(
FAN
SPEED
button
--
This
button set air
rate.
rORS
T
CU<O
SWING
button
1~
,
!1::
"'
This
button
changes
the
flap
mode:
(O
PERATION MODE sel
ect
button
now,sw
ing
or
fixed
wind.
na
tural
T
his
button
changes
the
operation
mode:
AUTO,COOL,DRY,HEAT,FAN.
J
w '
ECON
Obutton
)
GJG
This
button
changes
the
economy
(
SLEEP
button
This
button
cflange
to
SLEEP
operation.
<9
~
MN
HI POWER button
)
( TI
MER
button
This
button
changes
to HIGH
PO
This
button
is used
to
set
the
switch-on
or
TIME
SET
button
mode.
WER.
switch-orr
time.
This butt
on set
present time.
NOTE:
Above
figure
shows
all indications for
the
purpose
of
explanation,
but
practically
only the
pertinent.When
air-condition
er
is
ccoling-only
model,
the
HEAT
changes
to
FAN.
-12-
e
OPERATING
MACHINE
IN
SELECTED
MODES
1.
P
oint the
remote
controller
at
the
unit,pre
ss
the
ON/OFF
butto
n,
then
press
the "MOD
E"
button,select
the
need
ed
mode: AUTO,COOL,DRY,HEAT,or
FAN.
2. Press
the SET
TEMPERATURE button
to
increase
or
decrease
the
readi
ngs
until the
needed
tempera
ure
is
di
splay
ed.
The
room set te
mpera
ture rang
is fro
m16'C-32'C(61'F-90'F).
3.
Press the FAN
SPEED button
to
choose
the
air
rate
you
want: low(
display
indicates
" !
"),Me
d(d
isplay
indicates
"
~~~
",Hi(d
ispl
ay
indi
cates"~
~~~
",Auto(display
indicates"
AUTO'
).
4. P
ress the SWIN
G b
utton
to
choose
the up/
down
air
flow direction
you
want:na
tur
al
now(
display indicates
"Yr"),sw
ing(display
indicates"\:
") ,fixed
wind( no
indications).
e
ADJUSTING
LEFT/RIGHT
AIR
FLOW
DIRECTION
Adjust the
direction
by
moving dir
ectly the left/right air flow dir
ection adju
sting
fin by
hand.
Caution:when adjust t
he
directl
on,stop
air
conditione
r.
e
HIGH
POWER
OPERATION
Press
HI POWER butt
on during
ope
ration,the
air rate
can
be
set
in "HIGH"and
continues
to
operate
20 minutes.
Press
the
HI
POWER
button
again
can
release the
HI
POWER
operation
.
e
ECONOMY
OPERATION
Press
ECONO
butt
on
duri
ng "COOL"
operation,
the
setted-tempe
rature
can
raise 2'C(4'F),while
in
"HEAr'ope
ration,the
setted·temp
erature
can
decrease 2'C(4'F),and the
air rate
can
be
set
in "LO
W".
Press
the
ECONO
button aga
in
can
re
lease
the
ECONO
operation
.
NOTE:
In DRY mode
,the unit will
automatically
run
as following
operation
state:25
'C (76'F
)se
t t
empe
ratur
e,
fixed
wind air flow,low
speed
air rat
e.
HI
POW
ER and
ECONO
operations
do
not
work
on this mode
.
e
PRESENT
TIME
SETTING
PROCEDURE
1. When
cells
are
inserted
,push
the
CLK butt
on with
the
tip
of a
ball
pen,etc.The
time indica
tor
is
flicke
rin
g a
nd
can
set
the
prese
nt
time.
2.
Pre
ss the
HOUR button
to
set
you
desired time.
3.
Press the M
IN
butto
n to set you
desired time.
4.
Press the
CLK
button again
and the
prese
nt
time is
confirme
d.
If
when the
remote
controller
is
at abno
rmal state,
you
can
press the
RST button
to
clear off
the
display.
e TIMER
OPERATION
Set
turning
off
time
Set the
time for
the
unit
to
turn
off
and
when
it is
time, the
air
conditio
iner
will
automatically stop
operati
ng.
1.
During the
oper
ati
on
of the
air conditione
r,
press
the
TIMER
button
and the
air
conditioner
will
enter the timed
,
switch-off mode
.
2.
Gently
press the
TIMER button
to
set
the
needed time
for switchi
ng
off the machi
ne.
The timer
can
make
the
setting
in
the range from 1-
24 hour
s. Every the
button
is
pressed,indication
change
is the followi
ng
sequence
:
1
- 2 -
........ -24 -cancel
(no
indica
tion)-1.
3.
After
the settin
g of
the timed switch-off,
the
digits
shown
on the
display
screen
will
go
down
by 1 for
every
ela
psed
hou
r.
The di
splayed
digits
indicate the
remain
ing
time
prior
to the timed swi
tch-
off.
Set
turning
on
time
Set
the time for
the unit
to
tum
on
and
when
it
is time,the
air
cond
itioner wi
ll
automatically
start oper
ating.
1. Whe
n t
he
air
cond
itioner is
in the
standby mod
e,
press
the
TIM
ER butto
n a
nd
the air
conditioner will
enter
the
timed
switch-on mode
.
-1
3-
2.Gently
press the
TIMER
butto~
to set t
he
needed time
for
switching
on the
machine. The
timer
can
make
the
setting
in
the ran
ge
from
1-24
hours. Every
the
button
is
pressed,indication
change is
the
followi
ng
sequence:
1 - 2 -
........ -24
-
cancel
(no
Indication)- 1.
3.
After
the
setting
of
the timed
switch-on,
the
digits
shown
on
the
display
screen
will
go
down
by 1 for
every
elapsed
hour. The
displayed
digits
indicate
the
remaining time
prior
to
the timed
switch-on.
Re
leasi
ng
procedure . .
When the
indication
on
display scr
een
is
24
h
our,
press the TIMER butt
on
aga1n
to del
ete
the t1med
mode.
e
SLEEP
OPERA
T/ON
Use
this mode to
reduce
operation
sound
when sleeping,etc
.
Press
the SLEEP button, the
air flow
sound
from
the indoor
unit
is
decreased
and
the light
of display
screen will
be
closeed .Press
the
SLEEP button
again
can release
the
mode.
NOTE:
Use
the
sleep
mode
when
you
are
going
to
bed.
lf
this
mode
is
used
in
the
day,the
capacity
is
reduced
since
the
ambie
nt
tempe
rature
is too high.(COOL
MODE).
During
the
operati
on
of
cooling,the
room
temperature
will
be
raised
gradually
by 2'C(4
'F)
higher
than
the
setti
ng
after
the machine beg
ins
to
operate
in
the
sle
eping mode.
During
the
operation
of heating mode,the
room temRerature will
be
dropped
gradually 5'C(9'F) lower than
the
setting
after
the
mach
ine
begins
to
operate
in
the
sleeping
mod
e.
e
REPLACEMENT
OF
BATTERIES
• Wh
en the
signal f
rom
the
remote
controller
becomes weak
and
the
in
door unit
can
not
receive
it
properly
;or
the
ind
ications
on
the
display
screen
becomes
blurred,please slide
the
back
cover
and
replace
with
two
new
batter
ies
.
The
positive
and
negative
poles
must
match
the installation
positions.
New
batte
ries
of
the
same ty
pe have
to
be
used for
replacement.
• If
the
remote
controller
is
not
to be
used for long time, take
out
the
batteries
so
as
to prevent the leaka
ge
of
the
electrolyte from
damaging
the
controller
.
e
Basic
principles
and
performances
0 T
he
machines
absorb
heat
from
the
outdoor
air
and
transfer
it
indoors
so
as
to
heat
the
roo
m air.
The
heating
c
apabil
ities
through
this
principle
of
heat
pump
go
up/down
with
the
increase/decrease
of
the
temperatures
of
the
outdoor
air.
0 It
only needs a fairly
short time for
such
hot
air ci
rculation
system
to raise
the
room
temperature.
0 Wh
en
the ou
tdoor
air tem
perature
is
very
low,
the
system can
be
used
together with
other heat
ing
devices.
But good
ventilation
should
be
maintained
to
ensure
safety
and prevent
accidents
.
e
Defrosting
When the
outdoor
air
temperature
is
very
low
and humidity
is
very
high,
frosting
will
occur
to
the
heat
exchanger
of
the
outdoor unit, which
has negative
impacts
upon
the
efficiency
of
the
heating
performance. In
such
case, the
automatic
defros
ting
function
will
come into
play.
The
heating
operation
will
be
stopped
for
5-10
minutes
to
do
the
defrosting
.
0
The
fans
of
both
the
outdoor and
indoor uni
ts
are
stopped.
0
During
the
defros
ting, the
outdoor unit
might
generate
some stea
m.
It
is
caused
by fast
defrosting, which
is
not a performance
failure.
0
Upon
the
completion of
the
defrosting
process,
the
heating
operation
is
resumed.
-14-
e
OPERATION
TIPS
1.Set a suitable room temperature;excessively low room temperature is not good for your
health and wastes
electricity. Avoid frequent setting
of
the temperature.
2.During
cooling,avoid direct sun.Keep curtains and blin ds
closed, Close
doors and windows to keep the cool
air
in
the room.
3.Avoid generating heat
or
using
of
heating appliances
while
the
air
conditioner in cooling mode .
4.Make sure that the
air
flap is posit ioned properly :
horizontal flow in cooling and downward vertical flow
for
heating.
5.Keep the room temperature uniform by adjusting the left/
right vertical air blades.
6. Position the
air
flap and the left/r ight
air
blades
in
such a manner as to prevent your body from being exposed directly to
air
drafts.
7 .During
pro longed operation, ventilate the room
occasionally by opening a window from time to time.
8.
In
a power failure, the microprocessor memory is reta ined
.When restarted, operation
will be resumed
in
the last
mode
of
operation. However,
if
the timer was used,the
unit
will be turned
off
by the
timer only
if
the remote
control is aimed at the unit.Otherwise the power failure
will
cause the timer data to
be
erased from the
microprocessor memory.
9.
After
turning on,allow more than 3 minutes
for
cooling,
heating
or
dry
operation to
start
10.When DRY mode is used,make sure
that
the room
temperature is between
20.C/68.Fand
2TC/81
·F.When
used out
of
this range, the
unit
may
protect itself and
become inoperative.
11.When
COOL or DRY modes are used,make sure
that
-15-
the room's relative humidity is below 78%.
If
the unit is
used for a
prolonged periods of time
in
high humidity,moisture
may form on the
air
outlet and drip down.
12.Remote control signals may not be received
if
the
indoor
unit controls cover is exposed to direct sunlight
or
strong
light.ln such a case,block the sunlight
or
dim the lighting .
13. The remote control is operative
in
a range
of
8 meters
(26FT).If you are out
of
range,the remote control may
have difficulties
in
transmitting signals .
-
16-
CARE
AND
MAINTENANCE
Before performing any maintenance procedure,make sure to disconnect the
air
conditioner from the power.
e
CLEANING
THE
AIR
FILTER
To remove the
air
filters ,lift up the panel,push the air filters
up slightly to unlock them.pull out the filters,Ciean the filt
er
by washing in warm soapy
water
and dry thoroughly,align
and fit the filters
in
place,close the panel by pushing it in the
center
to lock it in place.
DO
NOT
OPERATE
THE
UNIT
WITHOUT
FILTERS
!
e
CLEANING
THE
AIR
CONDITIONER
1.Wipe the unit wit h a soft dry cloth or clean
it
using a
vacuum
cleaner .
2.Do not use hot
water
or volatile materials which could
damage the surface
of
the
air
conditioner.
e
AT
THE BEGINNING
OF
THE
SEASON
1.Make sure there are no obstacles blocking the flow
of
inlet or outlet air,in both
indoor
and
outdoor
units.
2.Make sure the power is
properly connected.
e
PROTECT
THE
ELECTRONIC
SYSTEM
1.1ndoor unit and remote control
must
be at l
east
1 meter
away from a TV,radio or any other home
electronic appliance.
2.Protect the inner unit from direct sun or lighting.
-17-
TROUBLESHOOTING
Before
calling
for
service,please
check
the
following
common
malfunctions
and
correct
it
as
needed
.
Problem
Cause
Remedy
e Unit does not
0 Remote control
+Check
remote
control
batteries
operate ,stand-
mafunctions
+Try
to operate
from
a close
by indicator
d
is
tance
lights.
0 The remote
+Sta
rt
from
on-unit controls
control
is locked
+Unlock
the
rem
ote
control
e Unit does
not
0
IR
signal
does
not
Check for obstruction
reach
unit
between unit
and
remote
respond
0 Distance
between
control, clear if
needed
.
properly to
remote control
and
unit
too
large
or
Get
closer
to
unit.
remote
control
ai
med
at from
command
improper
angle
Dim
ligh
ts,
fluorecents
0
IR rece
iver on-unit
especially
exposed
to strong
light source
e Air does
not
0 De-ici
ng
protection
+
Normal
operation
in
HEAT
ING
mode
blow out from
mode
is activated
0 Unit
AUTO
FAN
mode
+ Normal operation in
DRY
indoor
unit
mode
0 Over cooling
in
DRY
ecOOLING
,DRY
or HEATING
0
3-m
in.C
omp
ressor
+Normal
operation
for
these
does not start
delayed
sta
rt
modes
immediately
e Unit functions
0 Improper
tempe
rat
ure
+ Reset temperature
but does not
se
tting
perform
o unit capacity
in
+
Consu
lt
your
dealer
sufficient for l
oad
or
sufficiently
ro
om
size
-18-
e
Self
Diagnosis
Funtions
Our
company
has
provided
the
thoughtful
services
for
customers,and
the
air
conditioner
had
been
installed
self
diagnosis
system
to
display
the
code
for
failure
.
(1)
Indoor
unit
fault
shows
as
following
:
Failure
Failure
code
Communication failure
F1
Failure of room temperature sensor
F2
Failure
of
tube-exit temperature sensor
F3
Failure
of
tube-entry temperature sensor
F3
Failure
of
tube-midpoint temperature
sensor
F3
Failure
of
PG
fan
F4
(2)
Outdoor
unit
fault
shows
as
following:
Fau
lt
Fault
code
Fault
of
outdoor unit transducer module
P2
protecting. Outdoor unit AC input
too
big.
P3
O
utdoor
unit compressor exhaust
te
mp
erature too high,outdoor environment
P4
temperature ultra warm,compressor
outer
cover temperature switch disconnection. The outdoor machine direct current bus
P7
bar is unusual in voltage.
Fault
of
lack refrigerant or
fault
of
P8
reversing valve.
Fault
of
the outdoor temperature sensor.
F6
Fault
of
outdoor unit drive,fault
of
FC
compressor start.
- 1
9-
EXCEPTION
FOR
MUL
Tl
SPLIT
TYPE
The
same
outdoor
unit,it
may
happen
that
the
requested
operation
mode
can
not
be
operated
.
The
reason
for
that
is
that
the
system
is
currently
operating
in a
different
mode.
The
system
operation
mode
can be
either
cooling
or
heating
and
is
set
by
the
outdoor
unit
controls,based
on
indoor
and
outdoor .unit
settings.
The
rules
for
the
mode
settings
may be
different
from
one
application
to
another
.
In
most
applications
the
system
operation
mode
will
not
be
changed
as
long as
there
is
an
operating
indoor
unit
requesting
the
active
mode. The
operation
mode
in such
application
will
be
set
by
the
first
indoor
unit
that
is
turned
ON from
Stand
By .
The
following
tab
le
shows
the
indoor
unit
operation
modes
that
can be
operated
per
active
system
mode
:
System Active
Mode
Coolin
g Heati
ng
V
entilation
v
X
Requested
Cooling
X v
indo
or
unit
Heating
v X
opera
ti
on
Dry
v (
cooling onl
y) v(heating
onl
y)
mo
de
Auto
Cool/Heat
v
X
(v
-enabled
indoor
unit
operation
mode ,X-disabled
indoor
unit
operation
mode)
Indoor unit operation when the requested mode is disabled is as following:
1.Louver
opens
;
2.Green(OPER)LED
blinks
once
in
two
seconds
;
3.1ndoor fan is
forced
off
.
-20-