RAMSET RAM-1000 UL, RAM-5500 UL Instruction Manual

©
No. 545327
US
®
C
Instruction Manual
Model RAM-1000 UL & RAM-5500 UL
Rev 060202
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 1 -
TABLE OF CONTENTS
Important Safety Requirements & Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,2
Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Installation Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Pad Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Recommended Wire Gauge / Voltage Drop Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Gate Travel Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Pushbutton Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
INTELLIGATE PCB MOTOR CONTROLLER SPECIFICATION
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
DIP Switch Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8,9
TERMINAL STRIP CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Sensor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Master - Slave Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Bill of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
RAM-1000 UL Parts Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
RAM-5500 UL Parts Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
IMPORT
ANT SAFETY REQUIREMENTS & INSTRUCTIONS
WARNING - To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate
controls. Keep the remote control away from children.
3. Always keep people and objects away from
the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the Vehicular Gate Operator monthly. The
gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the limit of travel, retest the Vehicular Gate Operator. Failure to adjust and retest the Vehicular Gate
Operator properly can increase the risk of injury or death.
5. Use the Emergency Release only when power
switch or circuit breaker has been turned off. Using the Emergency Release during a power failure can be a hazard if power is abruptly restored.
6. KEEP GATES PROPERLY MAINTAINED.
Read the Owner's Manual. Have a qualified service person make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians
must use separate entrance.
8. SAVE THESE INSTRUCTIONS.
NOTE: Always consult and follow all local building and electrical codes prior to installation.
Ramset Gate Operators should not be installed without non-contact sensing devices such as non-con­tact sensors, photo electric sensors or the equivalent.
n
WARNING
A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installation to comply with UL325.
Reversing Sensors (Loop Detectors)
Reversing Sensors should be used to prevent gate from closing when a vehicle is in the gate area.
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 2 -
Installation should be done by a qualified installer only.
Prior to Installation, the following must be observed: (per UL 325 51.8.4)
a) Install the vehicular gate operator only when:
1) The Vehicular Gate Operator is appropri­ate for the construction of the gate and the usage Class of the gate,
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2-1/4 inch (57.15 mm) diameter sphere from pass­ing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
3) All exposed pinch points are eliminated or guarded, and
4) Guarding is supplied for exposed rollers.
b) The Vehicular Gate Operator is intended for
installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening.
c) The gate must be installed in a location so
that enough clearance is supplied between the gate and adjacent structures when open­ing and closing to reduce the risk of entrap­ment. Swinging gates shall not open into public access areas.
d) The gate must be properly installed and work
freely in both directions prior to the installa­tion of the Vehicular Gate Operator. Do not over-tighten the operator clutch to compen­sate for a damaged gate.
e) Controls must be far enough from the gate so
that the user is prevented from coming in contact with the gate while operating the con­trols. Controls intended to be used to reset a Vehicular Gate Operator after 2 sequential activations of the entrapment protection device or devices must be located in the line­of-sight of the gate. Outdoor or easily acces­sible controls shall have a security feature to prevent unauthorized use.
f) All warning signs and placards must be
installed where visible in the area of the gate.
g) For Vehicular Gate Operators utilizing a non-
contact sensor in accordance with 30A.1.1 Type B1 non-contact sensor (photo electric sensor or the equivalent)
1) See instructions on the placement of non-contact sensors for each Type of application,
2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and
3) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perime­ter reachable by a moving gate or barrier.
h) For a Vehicular Gate Operator utilizing a con-
tact sensor in accordance with 30A.1.1
1) One or more contact sensors shall be located at the leading edge, trailing edge, and postmounted both inside and outside of a vehicular horizontal slide gate.
2) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
3) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
4) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the vehicular gate operator is not subjected to mechanical damage.
5) A wireless contact sensor such as one that transmits radio frequency (RF) sig­nals to the vehicular gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 3 -
MECHANICAL SPECIFICATIONS:
RAM-5500 UL
foot pedal release
foot pedal release
RAM-1000 UL
Model:
RAM-1000 UL RAM-5500 UL
Power Input:
120VAC 120VAC
Continuous Duty Motor:
1/2 HP, 120VAC, 4.5 A, 1,625 RPM with High Speed Bearings
3/4 HP, 120VAC, 8.5 A, 1,625 RPM with High Speed Bearings
Capacitor:
Aerovox 65µƒ, 240 V, 50/60 HZ, protected S 10000 AFC
Aerovox 65µƒ, 240 V, 50/60 HZ, protected S 10000 AFC
Cycles:
Continuous Continuous
ON/OFF Switch:
120 VAC & 2 outlets 120 VAC & 2 outlets
Max Gate Length:
35 ft. 45 ft.
Max Gate Weight:
1000 lbs 1500 lbs
Gate Travel Speed:
12 inches per second 12 inches per second
Reduction:
By worm gearbox continually lubricated in an oil bath.
By worm gearbox continually lubricated in an oil bath.
Fini sh & C h a ssi s:
Rust-preventing Gold/Zinc coated 3/16" sheet metal
Rust-preventing Gold/Zinc coated 3/16" sheet metal
Gate Stops:
with limit switches with limit switches
Cha in:
20 ft. of Nickle-plated chain to inhibit corrosion 20 ft. of Nickle-plated chain to inhibit corrosion
Cove r:
Polyethy lene, high-impact resistance Polyethy lene, high-impact resistance
Color:
Charcoal Gray Charcoal Gray
Emergency Release:
Shipping Weight:
95 lbs. 110 lbs.
Overall Dimensions:
W=13-1/2", D=14-1/2", H=22" W=16-1/2", D=14-1/2", H=26"
Depress foot pedal release to dis engage gate from motor so it can be opened manually in the event of an emergency. An optional battery backup system is also available.
1/2 HP MOTOR
3/4 HP MOTOR
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 4 -
These Sliding Gate Operators are factory preset for Left Hand Installations.
PAD CONSTRUCTION:
Dimensions given for pad are based on soil bearing shear of 2000 P.S.F. These fig­ures may have to be adjusted depending on local soil condition.
1. Construct form for mounting pad according to
dimensions shown on this page.
2. Locate mounting pad according to dimensions
given in illustration.
3. Level top edge of form.
4. Set reinforcing bars and wire mesh.
5. Mix concrete; pour mixture into form. Tamp
mixture. Level and finish surface after pouring is complete.
6. Allow pad to cure 48 hours, and remove
forms.
Figure 1
6-1/2”
6”
MIN
4” MIN
WALL
4”
6-1/2”
24”
Conduit for
power
Conduit for
Master-Slave
Conduit for low
voltage wires
18” x 18” x 24”
Concrete Pad
24”
6”
4”
4” MIN
18”
“B”
4-1/2”
“C”
18”
concrete
concrete
“A”
Gate
L
C
Wall
Figure 2
LH installation gate shown closed
Mark centers and install four 1/2-13 UNC Red-head Anchor Bolts
4” MIN
Gate
L
C
Wall
Figure 3
LH installation gate shown open
INSTALLA
TION SPECIFICATIONS
MODEL Dim "A" Dim "B" Dim "C" Dim "D" Dim "E" RAM-1000 UL 13-3/4" 8-1/2" 2-1/8" 14" 8-1/2" RAM-5500 UL 13.902 8.625 or 6.625 2.049 8.5 13.875
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 5 -
RUN START 14 GA 12 GA 10 GA 8 GA
120V Single Pha se 1/2 4.7 5.0 up to 50' 50-100' 100-200' 200-300' 120V Single Pha se 3/4 5.8 6.5 up to 50' 50-100' 100-200' 200-300'
AMPERES
MAXIMUM CONDUIT DISTANCE IN FEET
USING COPPER WIRE BY WIRE SIZE
INPUT POWER
MOTOR HP
RECOMMENDED WIRE GAUGE / VOLTAGE DROP CHART
Low voltage control wires must be run in a separate conduit to the operator.
E
D
Rear Installation
Gate Shown Fully Open
No tail on gate required
Figure 4
24”
Dim “D” minus distance deter­mined by pulleys
E
D
Center Installation
Gate Shown Fully Open
Figure 5
6” min.
Concrete Pad
2-1/2” diameter UHMW Pulley
No tail on gate required
18” x 18”
Concrete Pad
6” min.
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 6 -
GATE TRA
VEL
ADJUSTMENT
To adjust gate travel, depress spring loaded bracket and spin each Adjustment Nut to the required position (Figure 6). LED must turn on to indicate position open or close when limit switch is activated by limit switch adjustment nut.
PUSHBUTTON CONTROLS
Three pushbuttons are located under the dip switches for manual operation of the gate (see Figure 7). The open, stop, and close buttons can be utilized to set limit switches and verify proper system opera­tion when installing or servicing an operator.
Open
Pressing this button will cause the gate to open.
S
top
Pressing this button will cause the gate to stop moving.
Close
Pressing this button will cause the gate to close.
TURN POWER OFF BEFORE ATTEMPTING ADJUSTMENT
Adjustment
Nuts
Depress spring loaded bracket to free Adjustment Nuts.
Figure 6
OPEN
STOP
CLOSE
L.E.D.’s light up when function is activated
Figure 7
Limit Switches
ELECTRICAL CONNECTION
A 3 wire, 120VAC electrical circuit with a 15 amp independent circuit breaker is required for each oper­ator. Ideally, the electrical conduits should exit the concrete under the operator. Low voltage control wires must be run in a separate conduit to the operator as shown.
Intelligate© Control Board: The Control Board is completely solid state. L.E.D. readouts show the status of the operator and control systems allowing for instant troubleshooting. The PCB circuitry plugs into an edge connector eliminating the need to disconnect any wires when replacing the board.
n
CAUTION
Check that gate is clear of people or obstructions BEFORE
turning power ON to avoid injury.
n
WARNING
ALWAYS
TURN OFF POWER
WHEN SERVICING OPERATOR!
MAIN CPU
CHIP
OPEN
FULLY
OPEN
FULLY CLOSED
ALARM
JP6
1/2 A
10 A
JP5
JP7
JP2
1 2 3 4 5
6
7
8
9
10
11
12
13
14
15
16 17 18
19
20
STOP
CLOSE
A
M1
M2
B
COMMON
REVERSE
FIREBOX
EXIT
PHANTOM
ADDRESS 1
ADDRESS 0
MECH LOCK
DOOR-IN-DOOR
HIGH ERD SENS
SECURE CLOSE
MOM. SOS
RADIO CYCLE
ONE PASS
LAG DELAY
LAG MODE
REVERSE LOGIC
SLAVE MODE
ONÎ
60 SECS 1 1 1 45 SECS 1 1 0 30 SECS 1 0 1 15 SECS 1 0 0 10 SECS 0 1 1
5 SECS 0 1 0 0 SECS 0 0 1
DISABLED 0 0 0
RADIO
STOP
LIMIT 1
LIMIT 2
COMMON
COMMON
24V RECT
MAG ( - )
MOTOR 1
MOTOR 2
AC HOT
NEUTRAL
MAG ( + )
SOLENOID
CLOSE
TO
120VAC
Figure 8
( A )
( B )
TO LIMIT
SWITCHES
TO
RECEIVER
TO
MOTOR
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 7 -
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 8 -
INTELLIGATE PCB MOTOR CONTROLLER
SPECIFICATIONS
INTRODUCTION
Ramset’s “Intelligate” Control board is for operating a vehicular gate operator. The control board is available for either 110VAC or 220VAC, single phase, applications. The control board con­tains self adjusting ERD, left hand/right hand operation control, lead/lag capability, one-pass anti-tailgating, and options for 4 dif­ferent gate addresses. The control board also includes a rectified 24V, 750mA, output for providing power to peripheral devices such as radio receivers, keypads, alarms, phone entry systems, safety detectors…etc.
DIP SWITCH CONFIGURATION
Dip Switch A1 – 3: Automatic Timer to Close Gate
DIP
GATE OPEN DURATION
111 60 seconds 110 45 seconds 101 30 seconds 100 15 seconds 011 10 seconds 010 5 seconds 001 0 seconds 000 disabled – command required to close
Dip Switch A4 – 5: “ADDRESS 1 & ADDRESS 0”
Up to four separate entrance addresses are available for installations with multiple entrance or exit locations. Master and slave gates that work together should be set to the same address. (Side gates use the address setup)
DIP
FUNCTION
00 Default – Entrance 1 01 Entrance 2 10 Entrance 3 11 Entrance 4
Dip Switch A6: “MECH. LOCK”
Mechanical Lock
For motor assemblies that use a mechanical lock mechanism.
DIP
FUNCTION
‘off’ no effect
‘on’ “Solenoid” output, on the terminal strip is used to
disengage the mechanical lock prior to actuating the motor in either direction.
DIP SWITCH A7:
“DOOR-IN-DOOR”
Door-In-Door Used with a three button switch or a pedestrian entranceto stop
the gate.
DIP
FUNCTION
‘off’ normal operation ‘on’ normally closed contact. With an open contact the board
will stop the gate from moving until a close contact is reached.
DIP SWITCH A8
: “LOW - ERD - HIGH”
ERD Sensitivity
DIP FUNCTION
‘off’ Normal ERD sensitivity – Adjusts the ERD for standard
sensitivity.
‘on’ Adjusts the ERD sensitivity so that more pressure is needed
to stop the gate. (recommended: only use in windy areas)
DIP SWITCH B1: “SECURE CLOSE”
Secure Close
DIP FUNCTION
‘off’ Normal operation
‘on’ When power is lost, then regained, control board checks
status of gate. If open and safety devices are cleared, gate will close automatically.
*WARNING*
When installing or servicing an operator, make sure switch is off. If switch is ‘on’ gate will move when power is applied and severe injury may occur.
DIP SWITCH B2:
“MOM. SOS”
SOS Maintained/Momentary (Uses Firebox input)
DIP
FUNCTION
‘off’ Maintained contact closure – normal operation, releases
when contact closure is cleared.
‘on’ Momentary contact closure – releases only after a second
closed contact signal is received.
DIP SWITCH B3:
“RADIO CYCLE”
DIP FUNCTION
‘off’ Normal operation – gate only opens and closes on the limit
switches. If the gate is in travel then it will always open.
‘on’ Cycle mode – gate opens and closes on the limit switches,
but if in travel, then it will stop with a first command and reverse with a second command.
DIP SWITCH B4:
“ONE PASS”
DIP
FUNCTION
‘off’ Normal operation - fully opens and closes ‘on’ One pass mode - The gate will open until the "reversing
loop" is initially activated and then cleared. The gate will then close. If the "reversing loop" is then activated again, before the gate is fully closed, the gate will stop until the "reversing loop" is cleared, then continue to close.
ADDRESS 1
ADDRESS 0
MECH LOCK
DOOR-IN-DOOR
LOW-ERD-HIGH
SECURE CLOSE
MOM. SOS
RADIO CYCLE
ONE PASS
LAG DELAY
LAG MODE
REVERSE LOGIC
SLAVE MODE
ONÎ
1 2 3 4 5 6 7 8
Dip Switch “A”
Dip Switch “B”
60 SECS 1 1 1 45 SECS 1 1 0 30 SECS 1 0 1 15 SECS 1 0 0 10 SECS 0 1 1
5 SECS 0 1 0 0 SECS 0 0 1
DISABLED 0 0 0
Figure 9
1 2 3 4 5 6 7 8
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 9 -
DIP SWITCH B5: “LAG DELAY”
Lag on Close
One second lag on close
DIP SWITCH B6:
“LAG MODE”
Lag on Open
One second lag on open
DIP SWITCH B7:
“REVERSE LOGIC”
DIP
FUNCTION
‘off’ Left hand operation – standard installation ‘on’ Right hand installations – Reverses motor & limit switches
without having to move any wires.
DIP SWITCH B8:
“SLAVE MODE”
Master/slave
DIP
FUNCTION
‘off’ Master mode – single gate operation. All peripheral devices
are to be connected to the master operator.
‘on’ Slave mode – used to synchronize operation between two
gates. Commands are received from the master through a 3-wire, shielded cable.
TERMINAL STRIP CONNECTIONS
CONTROL INPUT DESCRIPTIONS
AC Hot & Neutral – 110 or 220 VAC to power the operator.
Voltage is predetermined at factory and cannot be changed by the installer or technician.
Close – Closes the gate. Used with three button stations or pushbuttons. Becomes active with a closed contact to com­mon.
Exit – Opens the gate. Used with loop detectors, photo eyes, keypads, phone entry systems, three-button sta­tions…etc. Becomes active with a closed contact to com­mon.
Firebox/SOS – Opens the gate. Used with fire dept. key switches & controls. Becomes active with a closed contact to common, maintained or momentary depending on dip switch B2 (see “dip switch features”).
Stop – Stops the operator from moving. To be used as a non-contact sensor such as a photo-beam, edge connector or a three-button station. Becomes active with an open con­tact to common when dip switch A7 is in the ‘on’ position (see “dip switch features”).
Radio – Operation depends on dip switch B3 (see “dip switch features”). Used with an RF receiver or pushbutton. Becomes active with a closed contact to common.
SAFETY INPUT DESCRIPTION
Limit 1 & Limit 2 – Depending on dip switch B7 (see “dip
switch features”), stops the motor from moving in one direc­tion. These wires are preset in factory and should not be moved. Becomes active with a closed contact to common.
Phantom – Keeps the gate open when the open limit switch (A or B) is activated. Used with loop detectors. Becomes active with a closed contact to common.
Rev Loop – Stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate. If the gate is closed, the gate will remain closed. The function can be altered with dip switch B4 (see “dip switch features”). Used with loop detectors, photo eyes, safety edges…etc. Becomes active with a closed contact to common.
OUTPUTS
Mag (+) & Mag (- )
Supplies 24VDC to a magnetic lock when gate is closed. If gate is not closed then no power is supplied. Leave open if not used.
Motor 1 & Motor 2 – Supplies power to the motor. Direction depends on dip switch B7 (see “dip switch features”). These wires are preset and connected in the factory and should not be moved.
24V Rect. – Provides a rectified 24VDC for peripheral accessories.
Solenoid – Sends 110 VAC to a solenoid or other mechani­cal lock. Leave open if not used.
OTHER CONNECTIONS
Contact Closure Relay Outputs
Three separate isolated form-C relay outputs are provided. Each relays contact is rated at 125VAC, 2 amps.
1. Alarm – When ERD is triggered twice, before reaching a
fully closed or fully opened position, 24VDC is supplied for 6 minutes and the control board will not accept any commands. After the 6 minutes the 24VDC is removed and the board resets to normal operation.
2. Triggers relay when gate is fully opened. Used with indi-
cator lights, buzzers, beepers, misc. voltage magnetic locks…etc.
3. Triggers relay when gate is fully closed. Used with indi-
cator lights, buzzers, beepers, misc. voltage magnetic locks…etc.
Note: if both B5 & B6 are 'on', there will be NO lag on the open or close.
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 10 -
Power must be turned OFF before servicing operator. Power must be turned OFF
before attempting to adjust the limit switches.
Power must be turned OFF
for power failure release.
n
CAUTION
Electronic Control Board must be serviced by a certified technician only.
1 2 3 4 5
6
7
8
9
10
11
12
13
19
20
14
15
16 17 18
COMMON
REVERSE LOOP
FIREBOX
STOP
PHANTOM
RADIO
EXIT
LIMIT 1
LIMIT 2
COMMON
COMMON
24V RECT
MAG ( - )
MOTOR 2
MOTOR 1
AC HOT
NEUTRAL
MAG ( + )
SOLENOID
CLOSE
Figure 10
3 Wire Radio Receiver
Capacitor
Radio
Terminal Strip
Mag Lock
Solenoid
BL
BK
BK
RD
WH
Legend
RD = Red WH = White BL = Blue GR = Green (Ground) BK = Black YL = Yellow
WH
WH
WH
WH
YL
GR
RD
RD
BL
BK
BK
BK
Motor
BL
RD
TO 120VAC
TO NEUTRAL
POWER SWITCH
120V AC
120V AC
or 220V AC
or 220V AC
N.C.
N.O.
N.O.
Limit Switch
Limit Switch
C
C
N.C.
Firebox
Pedestrian
Switch
Phantom
Loop
Exit Loop
Open
3 button station
N.C. Contact
Common
Stop
Close
Reversing Loop
1
2
3
WIRING DIAGRAM
12 - Common
7 - Radio
13 - 24V RECT
White
Yellow
Black
12 - Common
7 - Radio
13 - 24V RECT
4 Wire Radio Receiver
Radio
Terminal
Strip
Gray
White
Yellow
Black
1
2
3
Black
Red
Gray
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 11 -
n
WARNING
A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installa­tion to comply with UL325.
Reversing Sensors on the ground floor prevent gate from closing when vehicle is in loop area. Exit Loops on the ground floor opens gate when vehicle crosses loop area.
Master - Slave Installation
SENSOR INSTALLATION
6 feet min
typical
Inside Property
Outside Property
Twist wires outside of loop
3 feet
min
Reversing
Loop
Reversing
Loop
Exit Loop
3 feet
min
3 feet
min
Figure 11
4 feet
min
4 feet min
4 feet
min
2-4 feet
Primary Operator is factory pre-set for LH operation
Do not twist wires inside loops.
1/4"
1-1/2"
Figure 12
Use 3-stranded, shielded wires (not supplied) from Master to Slave.
Use jumper JP6 to JP6
SLAVE MODE
REVERSE LOGIC
JP6
Use jumper JP6 to JP6
JP6
ONÎ
Set Dip Switch
“Slave Mode” to ON for Slave Operator.
RH operation requires Dip Switch “Reverse” to be ON.
Route low-voltage wires for Master/Slave in a conduit separate from power.
ITEM PART # PART DESCRIPTION RAM-1000 UL RAM-5500 UL
1 50-031 1/2 hp 115 vac electric motor 1 2 50-039 20 pin edge connector 1 1 3 50-058 3 1/2" uhmw idler pulley 2 2 4 50-069 limit switch 00-h3 2 2 5 50-087 # 41 x 20' gate chain 1 1 6 50-089 3/8" x 2" x 6" chain bracket 2 2 7 50-090 1/2" x 4" chain bolt 2 2 8 50-091 # 6 x 1" machine screw 2 2
9 50-092 3/8-16 x 1 1/4" hex head bolt 4 4 10 50-095 5/16-18 unc x 3/4" hex head bolt 2 2 11 50-097 5/16" flat washer 2 2 12 50-098 5/8"-11 x 3 1/2" hex head bolt 2 2 13 50-099 5/8" flat washer 2 2 14 50-101 3/8" lock washer 8 8 15 50-103 3/8" hex head nut 4 4 16 50-105 # 6 hex head nut 4 4 17 50-106 5/8" hex head nut 4 4 18 50-107 # 6 x 3/8" machine screw 3 3 19 50-113 1/2" hex head nut 4 4 20 50-114 1/4-20 socket head screw 4 4 21 50-145 1/2" x 3" tension spring ( pedal ) 1 1 22 50-151 warning sing for gate 2 2 23 50-168 horn alarm 1 1 24 50-208 limit switch nuts 2 2 25 50-212 1" tension spring 2 2 26 50-215 rocker switch 1 1 27 50-240 3/16" hot -roll metal 1 28 50-242 speed reducer size 60 1 29 50-244 polyethylene cover 1 30 50-245 limit switch chain 1 31 50-246 1" x 7" limit switch shaft 1 32 50-247 3/4" ball bearrings 2 2 33 50-248 4 pin disc release 1 1 34 50-249 1" arbor release 1 1 35 50-250 41 b 27 clutch release sprocket 1 1 36 50-251 41 b 12 x 3/4" sprocket 1 1 37 50-252 board metal cover 1 38 50-253 3/4" shaft collar 2 2 39 50-254 spring load bracket 1 40 50-256 3/4 HP 120 VAC electric motor 1 41 50-264 1/4" x 1-1/2" key way 1 1 42 50-265 3/16" x 3/4" key way 1 1 43 50-295 #8 self-tap sheet metal screw 2 2 44 50-299 radio receiver terminal 1 1 45 50-501 3/16" hot rolled metal chassis 1 46 50-502 board metal cover 1 47 50-503 polyethylene cover 1 48 50-504 speed reducer size 50: 30:1 ratio 1 49 50-505 1" x 6" limit switch shafth 1 50 50-506 spring load bracket 1 51 50-510 outlet switch cover 1 1 52 50-511 120 vac double outlet 1 1 53 50-513 1/4" X 3/4" counter sinc bolt 2 2 54 50-514 pedal release fork 1 1 55 50-515 limit switch chain 1 56 50-516 3/16" clutch release spring 2 2 57 50-517 1/4" x 3/8 sink screw 2 2 58 50-518 1-1/2" external snap ring 11 59 50-519 3/8" x 1-1/2" carriage bolt 4 4 60 50-520 # 6 x 5/8" machine screw 4 4 61 50-540 5/16" lock nut 2 2 62 50-528 # 8 X 3/8" macine screw 4 4 63 50-777 inteligate control board 11
BILL OF MATERIAL FOR RAM-1000 UL AND RAM -5500 UL
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 12 -
4
20
32
49
50
25
46
18
60
2
58
45
62
26
52
51
21
61
20
11
8
47
22
6
7
19
43
44
16
5
58
36
42
13
48
1
33
34
41
3
12
14
57
17
56
59
35
15
23
53
54
55
38
24
63
RAM-1000 UL PARTS DIAGRAM
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 13 -
Figure 13
RAM-5500 UL PARTS DIAGRAM
Figure 14
4
20
32
31
39
25
37
18
60
2
58
27
62
26
52
51
21
61
20
11
8
29
22
6
7
19
43
44
16
5
58
36
42
13
28
40
33
34
41
3
12
14
57
17
56
59
35
15
23
53
54
55
38
24
63
RAMSETzRAMSETzRAMSET
RAMSET
z
RAMSET
z
RAMSET
- 14 -
VISIT
VISIT
OUR WEBSITE
OUR WEBSITE
AATT: WWW
: WWW
.RAMSETINC.COM
.RAMSETINC.COM
Ramset Automatic Gate Systems z (800) 771-7055 z 9116
De Garmo Ave. z Sun Valley, CA. 91352
GLOSSARY
CLASSES OF VEHICULAR GATE OPERATORS
VEHICULAR HORIZONTAL SLIDE-GATE OPERATOR (OR SYSTEM)- A vehicular gate operator (or system) that con-
trols a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.
VEHICULAR SWING-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a gate which swings in an arc in a horizontal plane that is intended for use for vehicular entrance or exit to a drive, parking lot or the like.
RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I - A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR- CLASS II- A vehicular gate operator (or system) intended for use in an commercial location or building such as a multi-family housing unit (five or more single family units), hotels, garages, retail stores, or other buildings serving the general public.
INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR - CLASS III - A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
RESTRICTED ACCESS VEHICULAR GATE OPERATOR - CLASS IV - A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.