For the installation of the ASYM module you need an internal chamber inside the acoustic enclosure, separate from the chamber where the speaker is mounted. If preferred, the ASYM module can be supplied with a rear metal case for this purpose, avoiding having to make this space airtight.
The module is fixed to the enclosure with 8 M4 or M5 screws, sealing foam should be placed in the joint between the module and the box to avoid vibra­tions (it is not advisable to put foam in the joint between the module and the optional rear metal case).
In the drawings below you can see: (1) the external dimensions of the module (front/profile), (2) the optional rear metal case, and also (3) the recommended machining of the acoustic enclosure.
Installation Requirements
Für die Installation des ASYM Moduls wird ein eigenes Volumen im Lautsprechergehäuse benötigt, welches separat von dem des Lautsprechers ist. Wenn gewünscht kann das ASYM Modul mit einer metallenen Schale versehen werden, um diesen Bereich nicht extra luftdicht machen zu müssen. Das Modul wird mit 8 M4 oder M5 Schrauben am Gehäuse befestigt, in den Spalt zwischen Modul und Gehäuse sollte Dichtschaum gegeben werden, um Vibrationen zu vermeiden (Es ist nicht ratsam zwischen dem Modul und dem optionalen metallenen rückwärtigen Gehäuse ebenfalls Dichtschaum zu geben). In den Zeichnungen weiter unten kann man folgendes sehen: (1) Die äußeren Abmessungen des Moduls (von Vorne, von der Seite), (2) das optionale rückwärtige Gehäuse und (3) auch die benötigte Aussparung des Lautsprechergehäuses.
Installationsvoraussetzungen
Module
Assembly
Para la instalación del modulo ASYM es necesario tener una cámara interna en el recinto acústico, separada de la cámara donde está montado el altavoz. Opcionalmente, el módulo ASYM pude ser suministrado con un cajón metálico trasero para este propósito, y así evitar tener que hacer este alojamiento hermético en el recinto. La sujeción del módulo al recinto se realiza mediante 8 tornillos M4 o M5, y debe colocarse una junta de espuma entre el módulo y la caja para evitar vibraciones (no es recomendable poner esta junta entre el modulo y el cajón metálico opcional). En los planos de debajo de estas líneas se muestran: (1) las dimensiones exter­nas del módulo (frontal/perfil), (2) las del cajón opcional, así como (3) el mecanizado recomendado a realizar en el recinto acústico.
Requisitos de Instalación
Montaje
del Módulo
Modul
Zusammenbau
(3) Cabinet Mechanization
(2) Optional Aluminium Case(1) Profile-Front Dimensions
The connection of the speakers to the module is done using two JST VHR-2N connectors provided. A cable should be crimped to the terminals (1.25mm
2
section maximum) and placed on the connector box, so that the metallic tab fits into place.
The connection is as follows:
Speakers Connection
Der Anschluss der Lautsprecher am Modul erfolgt durch zwei JST VHR-2N Stecker. Ein Kabel wird auf die Anschlussstifte gecrimpt (maximal 1,25mm²) und ins Steckergehäuse gesteckt, so dass der metallene Stift einrastet.
Der Anschluss erfolgt wie folgt:
Lautsprecher Anschluss
Connection
and Description
La conexión de los altavoces al modulo se realiza a través de 2 conectores JST VHR-2N suministrados. Debe de crim­parse un cable a los terminales (sección máxima de 1.25mm
2
) e intro­ducir los mismos sobre la caja del conector, de forma que la pestaña metálica se aloje en su hueco. El conexionado es el siguiente:
Conexión de Altavoces
Conexión y
Descripción
Verbindung und
Beschreibung
Signal Input: Female XLR Connector for signal input.
Signal Link: Male XLR Connector for signal link.
Ethernet Connectors: RJ45, two ports Ethernet switch.
USB Connector: B type USB connection.
LED ON:power supply ON. Blinking indicates StandBy mode. LED SIGNAL: input signal presence indication. LED LIMIT: lights when the DSP limiters are working. LED CLIP: the maximum input or output has been reached.
Quick Preset: press the button for 3 seconds to change the
desired output preset.
ON: press SET1 button for 2s to turn on (in StandBy mode). LEVEL: push SET 3-4 buttons simultaneously to enter LEVEL
mode (both LEDs light up). Then use 3 and 4 to change level.
Mains connection: inlet and outlet powerCON True1 connection. It works also as a main switch, as it is a connec­tor with breaking capacity.
3
2
Front Panel Description
1
4
5
6
7
3
4
5
6
2
1
Optional Case
7
Technical Specifications Datos TécnicosTechnische Daten
©2018 by C.E. Studio-2 s.l. - Pol.Ind. La Figuera - C/Rosa Luxemburgo nº34 - 46970 Alaquas - Valencia - SPAIN
Phone:+34 96 127 30 54 Fax:+34 96 127 30 56 - http://ramaudio.com - e-mail: contact@ramaudio.com
RAM Audio®, ICL™, PMS™ and PowerPack™ are registered trademarks of C.E. Studio-2 s.l. All other names are trademarks of their respective companies.
DSP Specifications
Output Power Configuration AS 2K3 AS 1K5
(Selectable by channel) CH-A CH-B CH-A CH-B 8 ohm 1500W 400W 400W 400W 4 ohm 1500W 750W 750W 750W 2 ohm 750W 750W 750W 750W Bridge 8 ohm - 1500W Bridge 4 ohm - 1500W
Total Harmonic Distortion <0.05% <0.05% Efficiency >90% >90% Damping Factor (20-500Hz @8Ω) >400 >400 Voltage Gain 32dB 32dB Operational Mains voltage 85-265V AC/50-60Hz 85-265V AC/50-60Hz
Consum. @4Ω, 1/8 r.p., 230V AC 1.7 A 1.2 A
Power Factor >0.95 >0.95 Efficiency >90% >90% Dimensions
External Plate WxH 130x443 mm 130x443 mm Internal Enclosure WxHxD 100x423x55 mm 100x423x55 mm Occupied Volume (optional case) 2 l 2 l
Weight 1.5 kg 1.5 kg Connections: XLR Input, XLR Link, powerCON True1 in-out, USB, 2x RJ45, barrier strip (in optional case) Protections: Turn-on transients, Over-heating, DC, RF, Short-circuit, mismatched loads, ICL™, PMS™
Overall:
• High performance 96kHz 120dB 32 bits AD/DA converters
• 64 bit double-precision 96kHz DSP process
• 0.6ms minimum process latency time
• Up to 3000 taps custom FIR process
• Up to 562ms total audio delay
Input Section:
• Gain, Mute and Phase inversion
• Input Delay: 0 to 140 meters (406ms)
• Input EQ: 31 GEQ + 8 PEQ (Parametric, Shelving, LP, HP, BP, SB, AP)
Output Section:
• Crossover Filters: FIR and IIR (up to 48dB/oct, Butterworth / Linkwitz-Riley / Bessel)
• Output Delay: 0 to 18 meters (52ms) per channel
• Output IIR EQ: 12 filters per channel (Parametric, Shelving, LP, HP, BP, SB, AP)
• Output FIR EQ: 20 filters per channel (Parametric, Shelving, LP, HP, BP, SB, AP), or Custom up to 3000 taps
• RMS, Peak, and Thermal limiter per channel
Amplifier Specifications
Control & Monitor:
• Standby mode for remote turn-on
• Real time impedance monitor
• Stby., Signal, Lim, Clip, Temp and Prot monitor
• Input, Output, Temperature and Current meters
Communications:
• Two ports Ethernet switch for daisy chain connection
• USB 2.0, Type B connector
Overall:
• 20 Manufacturer preset memories library
• 5 User preset memories library
• 4 Quick Preset selection
• Manufacturer/Installer/User passwords
• Independent selectable output power per channel (Z dependant)
• User control groups for virtual Equalization, Gain and Delay
• Zone management for library, stand-by and alerts information
• Smaart
®
analysis software integration
RAM_OCS Control
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The exclamation point inside an equilateral triangle indica­tes the existence of internal components whose substitu­tion may affect safety.
The lightning and arrowhead symbol warns about the presence of uninsulated dangerous voltage.
To avoid fire or electrocution risk do not expose the unit to rain or moisture. To avoid electric shock, do not open the unit. No user serviciable parts inside. In the case of disfunction, have the unit checked by qualified agents. Class I device.
Loading...