WLED75CV1 User Manual
What is the WLED75CV1?
Rako WLED75CV1 modules are single channel dimmer units designed for use with constant
voltage LED devices (usually flexible single colour tape lighting). They are designed to
accept a 12V or 24V DC supply from a power supply (normally the power supply that would
power the LED device if it were not to be dimmed) and give a PWM (Pulse Width
Modulation) output for smooth flicker free dimming. They communicate over the Rako Wired
Network connected via a WP-CONC connection and can be used in both a daisy-chain and
star wiring configuration.
Installing the WLED75CV1
Mounting
Rako modules should be mounted in areas that are adequately ventilated, dry and outside of
any enclosed metal casings that may interfere with the wireless signal. Wherever possible
the mounting bracket should be used. Whilst Rako modules are designed to be completely
maintenance free the units should be mounted in an accessible location should there be a
fault or re-addressing of the unit be necessary.
Connections
Connect the WLED75CV1 module according to the wiring diagram above. The unit is
designed to be fed from a 12V or 24V DC power supply. The power supply should be of an
adequate rating for the connected load. For example, if dimming 4m of LED tape light with a
rating of 12V and 14.4W/m the power supply needs to be rated to give at least 57.6W. If
more than 5m of tape lighting is to be connected it is generally recommended to parallel the
WLED75CV1 Manual Version 1.0.2
connections at the WLED75CV1 module rather than connecting the start of the second strip
to the end of the first. This avoids excessive voltage drop issues.
Ensure the cable clamp bar securely clamps the cables and that the terminal cover is fitted
before switching the supply on.
Initial Checks
When power is initially connected to the module the unit should switch the load ON. The load
can then be manually switched using the clear button on top of the module.
The factory set address for both modules and transmitters is House 1 Room 4.
Should the module not respond as above then further investigation should be made before
proceeding further.
Maximum loadings
75W @ 12V
150W @ 24V
Adding the WLED75CV1 as a device
For the WLED75CV1 to operate correctly with a RAKO
system some initial setup must be performed. This is done
using a PC running RASOFT Pro (WLED75CV1 is not
supported by RASOFT classic) and communicating with a
RAKO Bridge connected to the same wired system as the
WLED75CV1.
Open the Project File for the installed Rako system and make sure that Rasoft is connected
to a communication device.
NB
The communication window at the bottom right should indicate whether a Bridge is connected or not. For
instructions on how to connect to a Bridge see Rasoft Pro programming guides.
- Select “File” - “New device” to bring up the “New device Wizard” and choose
“WLED75CV1” from the list.
- Choose a suitable device name (if you have multiple WLED75CV1 make sure it is
identifiable from this description). Leave “Device ID” blank with the “Automatic ID” box
checked.
- Associate the WLED75CV1 to a room from the drop down menu. The room selected here
will set the “Local Room” for this device, leave “Associate to channel” blank.
WLED75CV1 Manual Version 1.0.2