The PRF filter comes with a 200 mesh stainless steel filter installed.
RBY-200-SS-MX 200 mesh stainless steel filter element
Operation Range
Inlet Pressure 20 to 120 psi (1,8 to 8,3 bar)
Outlet Pressure Regulated at 30 psi (2,1 bar)
Water Temperature 33°F (0,5°C) to 110°F (43°C)
Ambient Temperature 33°F (0,5°C) to 125°F (52°C)
Valve Voltage 24 VAC 50/60 Hz (cycles/sec)
Related Products
XFD-xx-xx-xxx XF Series Dripline
Available in 0.6 or 0.9 GPH at 12”, 18”, or 24” spacing.
Rain Bird Corporation
970 West Sierra Madre Avenue, Azusa, CA 91702, U.S.A. Phone: (626) 812-3400 Fax: (626) 812-3411
Rain Bird Corporation
6991 East Southpoint Road, Tucson, AZ , 85706, U.S.A. Phone: (520) 741-6100 Fax: (520) 7
Rain Bird International, Inc.
P.O. Box 37, Glendora, CA, 91740-0037, U.S.A. Phone: (
626) 963-9311 Fax: (626) 852-7343
41-6522
1” Low-Flow Control Zone Kit
with PR Filter
Model:
XCZ-LF-100-PRF
Installation and Operation
www.rainbird.com
The Intelligent Use of Wat
® Registered trademark of Rain Bird Corporation © 2008 Rain Bird Corporation 7/08
er™ -- Visit www.rainbird.com to learn about our efforts
P/N 177630
Rev A
Assembly
1. Apply Teflon™ tape (1 ½ to 2 turns) to all male pipe threads. Do not use pipe thread or pipe dope compound.
2. Hand tighten components in the above configuration, no more than 2 turns past finger tight. Make sure the flow arrow on the filter in in the correct orientation. a. Low Flow Valve - 1” female NPT to 1” female NPT b. Reducer bushing - 1” male NPT to 3/4” female NPT c. Pressure-Regulating Filter (PRF) - 3/4” male NPT x 3/4” male NPT d. Multi-diameter Fitting (MDF) - 3/4” female NPT to poly tubing
Installation
5. Unscrew the cap of the Pressure-Regulating Filter and remove the filter element.
6. Replace cap without filter element.
7. Activate flow through the valve the valve either manually or using the controller. To Manually activate, turn the solenoid handle counter-clockwise ½ to ¾ turns.
8. Run water several minutes to flush the system.
9. Replace the filter element.
10. Prepare poly tubing 16mm to 18mm OD by cutting the tubing at least 1½” away from any emitter.
11. Check to see that the cut is clean and the tubing is not deformed (out of round).
12. Insert the tubing end into the Multi-Diameter Fitting, centering the tube on the white insert of the fitting. The tube should slide freely into the fitting for approximately ½” before meeting resistance.
13. After initial resistance, continue to insert the tube an additional ¾” until the tube reaches a full stop.
1. Install the Low Flow Valve on the water supply line.
2. Orient the Pressure-Regulating Filter down to prevent debris entering the line when the filter is removed for cleaning.
3. Do not install tubing or other downstream elements yet.
4. Connect one solenoid wire to the controller common and the other wire to the controller power. User only water-tight connectors, such as Rain Bird ST-03.
Note: Multi-diameter fittings cannot be reused.
Operation / Maintenance
1. Periodically remove the filter element.
2. If dirty, rinse the filter element in water before reinstalling.
Winterization
In a freezing climate, water should be removed from the irrigation system before freezing occurs. For more information, please refer to Rain Bird’s Winterization Guide, available at www.rainbird.com.
Technical Assistance
Internet: www.rainbird.com Toll Free: 800-247-3782