This manual contains information that is proprietary to RADWIN Ltd. (RADWIN hereafter). No
part of this publication may be reproduced in any form whatsoever without prior written
approval by RADWIN.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and
other intellectual property or other proprietary rights relating to this manual and to the
RADWIN products and any software components contained therein are proprietary products
of RADWIN protected under international copyright law and shall be and remain solely with
RADWIN.
The RADWIN name is a registered trademark of RADWIN Ltd. No right, license, or interest to
such trademark is granted hereunder, and you agree that no such right, license, or interest
shall be asserted by you with respect to such trademark.
You shall not copy, reverse compile or reverse assemble all or any portion of the User Manual
or any other RADWIN documentation or products. You are prohibited from, and shall not,
directly or indirectly, develop, market, distribute, license, or sell any product that supports
substantially similar functionality based or derived in any way from RADWIN products.Your
undertaking in this paragraph shall survive the termination of this Agreement.
This Agreement is effective upon your opening of a RADWIN product package and shall
continue until terminated. RADWIN may terminate this Agreement upon the breach by you of
any term thereof. Upon such termination by RADWIN, you agree to return to RADWIN any
RADWIN products and documentation and all copies and portions thereof.
For further information contact RADWIN at the address below or contact your local
distributor.
Disclaimer
The parameters quoted in this document must be specifically confirmed in writing before they
become applicable to any particular order or contract. RADWIN reserves the right to make
alterations or amendments to the detail specification at its discretion. The publication of
information in this document does not imply freedom from patent or other rights of RADWIN,
or others.
RADWIN 1000/2000 User ManualVersion 2.2bi
RADWIN Worldwide Offices
Corporate Headquarters
27 Habarzel Street
Tel Aviv, 69710
Israel
Tel: +972 3 766 2917
Support Headquarter
27 Habarzel Street
Tel Aviv, 69710
Israel
Tel: +972 3 766 2900
Mobile: +972 54 766 0044
RADWIN North America
900 Corporate Drive
Mahwah, NJ 07430
USA
Tel (1): 1 800 444 7234 / 341
Tel (2): +1 201 529 1100 / 341
Latin America Headquarters
Rua Grao Mogol 828
Belo Horizonte, MG 30310-010
Brazil
Tel (1): +55 31 919 76 402
Tel (2): +972 54 758 6808
India Headquarters
Mohan Co-operative Industrial Estate
E-13, B-1 Extn
New Delhi, 110044
India
Tel: +91 11 4053 9180
APAC Headquarters
1 Jalan Kuala #13-01
The Morningside, 239639
Singapore
Tel: +65 9878 3004
Indonesia Sales Office
Jl. Jenderal Sudirman Kav. 86
Jakarta, 10220
Indonesia
Tel: +62 8138 570 0657
Philippines Sales Office
37A. A luna St. West Rembo
Makati City, 1200
Philippines
Tel: +63 2882 6886
Mobile: +63 91 789 23427
China Sales Office
Asian Games Village
Huiyuan Gongyu J1312
Beijing 100101
China
Tel: +86 010 8498 0629
For technical support contact:support@radwin.com
For technical support in India only, contact: support-india@radwnin.com
For sales support contact:sales@radwin.com
Website: www.radwin.com
RADWIN 1000/2000 User ManualVersion 2.2bii
Regulatory Compliance
General Note
This system has achieved Type Approval in various countries around the world. This means
that the system has been tested against various local technical regulations and found to
comply. The frequency bands in which the system operates may be “unlicensed” and in these
bands, the system can be used provided it does not cause interference.
FCC - Compliance
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible
for compliance (RADWIN Ltd.) could void the user's authority to operate the equipment.
It is the responsibility of the installer to ensure that when using the outdoor
antenna kits in the United States (or where FCC rules apply), only those
antennas certified with the product are used. The use of any antenna other
Warning
Caution
than those certified with the product is expressly forbidden in accordance to
FCC rules CFR47 part 15.204.
Outdoor units and antennas should be installed ONLY by experienced
installation professionals who are familiar with local building and safety
codes and, wherever applicable, are licensed by the appropriate
government regulatory authorities. Failure to do so may void the product
warranty and may expose the end user or the service provider to legal and
financial liabilities. Resellers or distributors of this equipment are not liable
for injury, damage or violation of regulations associated with the installation
of outdoor units or antennas.
The antenna used for this transmitter must be installed to provide a
separation distance of at least 232 cm from all persons and must not be colocated or operated in conjunction with any other antenna or transmitter.
Warning
Indoor Units comply with part 15 of the FCC rules. Operation is subject to the following two
conditions:
RADWIN 1000/2000 User ManualVersion 2.2biii
This product was tested with special accessories - indoor unit (IDU or
PoE), FTP Cat 5e shielded cable with sealing gasket, 12 AWG grounding
cable - which must be used with the unit to insure compliance.
Warning
(1) These devices may not cause harmful interference.
(2) These devices must accept any interference received, including interference that may
cause undesired operation.
Canadian Emission Requirements for Indoor Units
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numẻrique de la classe B est conforme ả la norme NMB-003 du Canada.
RADWIN 1000/2000 User ManualVersion 2.2biv
Table of Contents
Notice....................................................................................................................... i
RADWIN Worldwide Offices.................................................................................... ii
Regulatory Compliance.............................................................................................. iii
TABLE 1-1 AVAILABLE ODU PRODUCTS - RELEASE 2.2B...........................................................1-7
T
ABLE 1-2 RELEASE 2.1 IDU-C PRODUCTS...........................................................................1-7
T
ABLE 3-1 COMPONENTSOFAN IDU-C FRONTPANEL ..............................................................3-9
T
ABLE 3-2 IDU-C FRONT PANEL LEDS ..............................................................................3-10
T
ABLE 4-1 PC REQUIREMENTSFORTHE RADWIN MANAGER APPLICATION...................................4-1
T
ABLE 4-2 RADWIN MANAGER: OFFLINE FUNCTIONALITY........................................................4-7
T
ABLE 4-3 DEFAULT SETTINGS ...........................................................................................4-9
T
ABLE 4-4 FRONT PANEL LEDS........................................................................................4-10
T
ABLE 4-5 RADWIN MANAGERMAINMENUFUNCTIONALITY ...................................................4-11
T
ABLE 4-6 RADWIN MANAGER TOOLBAR..........................................................................4-12
T
ABLE 4-7 LINK INSTALLATION WIZARD .............................................................................4-13
T
ABLE 4-8 RADWIN 1000/2000 TRANSMISSIONRATES .......................................................4-22
T
ABLE 5-1 RADWIN MANAGER TOOLBAR............................................................................5-3
T
ABLE 5-2 RADWIN MANAGERMAINMENUFUNCTIONALITY .....................................................5-4
T
ABLE 5-3 LINK DETAILS ..................................................................................................5-6
T
ABLE 5-4 LINKSITEDETAILS, SITE A AND SITE B .................................................................5-7
T
ABLE 5-5 STATUSBARINDICATORS....................................................................................5-9
T
ABLE 5-6 LINK CONFIGURATION WIZARD ..........................................................................5-10
T
ABLE 6-1 ODU MODECONFIGURATIONFORCOMMON ...........................................................6-11
T
ABLE 6-2 TELNET COMMANDS ........................................................................................ 6-20
T
ABLE 7-1 GET DIAGNOSTICS DATAAND DESCRIPTION ............................................................7-2
T
ABLE 7-2 LINK COMPATIBILITY TRAP MESSAGES ...................................................................7-3
T
ABLE 7-3 EXPLANATIONOFPERFORMANCEDATA....................................................................7-8
T
ABLE 7-4 ACTIONOFTHETOOLBARBUTTONS.......................................................................7-9
T
ABLE 7-5 RADWIN MANAGER TRAP MESSAGES.................................................................. 7-11
T
ABLE 7-6 ACTIVE ALARMSCOMMANDBUTTONS ...................................................................7-15
T
ABLE 7-7 LED FAULTINDICATORS ...................................................................................7-16
T
ABLE 7-8 TROUBLESHOOTING .........................................................................................7-16
T
ABLE B-1 ODU-IDU CONNECTOR PINOUT.......................................................................... B-1
T
ABLE B-2 FAST ETHERNET CONNECTOR PINOUT................................................................... B-2
T
ABLE B-3 IDU-C ALARM CONNECTOR (DRY-CONTACT) ......................................................... B-3
T
ABLE B-4 TERMINAL BLOCK 3-PIN -48VDC ........................................................................ B-4
T
ABLE C-1 BILLOF MATERIALS: ODU MOUNTINGKIT............................................................. C-1
T
ABLE F-1 SUPPORTED RFC 1213 VARIABLES .......................................................................F-4
T
ABLE F-2 PRIVATE MIB PARAMETERS.................................................................................F-5
T
ABLE F-3 MIB TRAPS................................................................................................... F-18
T
ABLE G-1 OUTPUT ALARMS PINOUT .................................................................................. G-1
RADWIN 1000/2000 User ManualVersion 2.2bxii
Welcome!
Chapter 1
Introduction
Welcome to the RADWIN 1000/2000 radio series, designed for the IP and
WiMAX Backhaul, Private Networks and Broadband Access global markets.
The RADWIN 1000/2000 series is an innovation in high-capacity carriergrade sub-6GHz radios, and designed to meet the requirements of current
and next-generation markets and applications. RADWIN 1000/2000 also
features software configurable antenna port activation enabling single
(RADWIN 1000) or dual (RADWIN 2000) antenna port operation. The
device configured as RADWIN 2000 has an advanced air-interface based on
MIMO, antenna diversity.
The RADWIN 1000/2000 radio series offers unmatched performance and
carrier-class quality with the following features:
•Superior spectral efficiency at 5, 10 and 20MHz channels
•High Ethernet capacity (up to130Mbps at 20MHz channel bandwidth)
•Combo frequency products for maximum flexibility
•Advanced air-interface based on MIMO, built-in diversity and OFDM
technologies
•Superior range performance
•Simple installation and management
•High Tx power
The RADWIN 1000/2000 radio series supports the 4.9 and 5.8 GHz spectrum bands, and complies with international standards and regulations
(FCC, IC Canada).
Key Applications
WiMAX and IP Backhaul
The RADWIN 1000/2000 radio series offers WiMAX operators and ISPs a
unique, highly scalable and cost-effective backhaul solution. Designed to
suit a wide range of topologies, RADWIN 1000/2000 is easy to install and
RADWIN 1000/2000 User ManualVersion 2.2b1-1
Broadband Access Chapter 1
maintain, enabling operators to quickly and efficiently expand their networks and introduce new services to a growing subscriber base.
Figure 1-1: Typical Wimax and IP Backhaul application
Broadband Access
With RADWIN 1000/2000, service providers can quickly and efficiently
expand their networks, and provide high-capacity services that meet the
increasing demand for high-quality, high-speed broadband.
Figure 1-2: Typical Broadband Access application
Private Networks
RADWIN 1000/2000 is the ultimate solution for private networks such as
enterprises, education, government and utility organizations that wish to
own and manage their own networks and eliminate the costly recurring
charges from service providers.
RADWIN 1000/2000's cost-effective solution enables a variety of organizations to connect geographically dispersed sites at ranges of up to 80km (50
miles).
RADWIN 1000/2000 User ManualVersion 2.2b1-2
Key Features of RADWIN 1000/2000 Chapter 1
Figure 1-3: Private Network
Key Features of RADWIN 1000/2000
Some of the outstanding features of the RADWIN 1000/2000 radio series
are as follows:
⇒ High Capacity
The RADWIN 1000/2000 system provides a high-capacity link of up
to 130Mbps at 20MHz channel bandwidth.
⇒ Superior Spectral Efficiency
Built on advanced MIMO and OFDM technologies, the RADWIN
1000/2000 system provides a high-capacity link at channel bandwidths of 5, 10 and 20MHz. These channel bandwidths support high
robustness of the air interface under interference and harsh conditions. In countries where applicable, narrow channel bandwidths
reduce the cost of the spectrum license.
⇒ Advanced Air Interface
The RADWIN 1000/2000 system provides an advanced air-interface
based on MIMO, built-in diversity and OFDM technologies, resulting
in an exceptionally robust air interface.
Using the following technologies, the RADWIN 1000/2000 air interface is designed to ensure nonstop, high quality transmission, even
under interference and harsh conditions:
•Automatic Adaptive Rate (AAR) is a mechanism that dynamically adapts the air interface rate by changing both the signal
modulation and coding.
•Automatic Channel Selection (ACS) chooses the best channel by
monitoring the available radio channels and dynamically selecting a channel which is best suited for transmission at any given
time.
•Automatic Repeat Request (ARQ) is a mechanism for error control during data transmission. When the receiver detects an
error in the received information, it automatically requests the
RADWIN 1000/2000 User ManualVersion 2.2b1-3
Key Features of RADWIN 1000/2000 Chapter 1
transmitter to resend the information. This process is repeated
until the transmission is error free or the error continues
beyond a predetermined number of maximum transmissions.
RADWIN 1000/2000's ARQ mechanism is optimized for timecritical traffic.
•Forward Error Correction (FEC) with very low overhead and
algorithms specifically designed for the varying conditions of
license-exempt frequency bands, ensuring fast, robust and
error-free communications.
⇒ High transmission (Tx) power of 29.95dBm
The RADWIN 1000/2000 system supports high Tx power, compliant
with radio regulations. High Tx power increases the system's availability and range, and enables the high performance with smaller
antennas, thus reducing the total cost of the solution (lower CAPEX),
installation and tower rent costs (lower OPEX).
⇒ Superior range performance
The RADWIN 1000/2000 system supports high capacity at superior
ranges. The Link Budget Calculator (appendix D) is used to determine the capacity and range according to the choice of product,
antenna, type of service and environmental conditions.
⇒ Simple installation and management
RADWIN 1000/2000 systems are extremely simple to install and
maintain. They are typically up and running in less than an hour.
The RADWIN Manager application has full local and remote management capabilities. The user-friendly SNMP based management tool
provides full end-to-end configuration, event logging, and performance monitoring capabilities.
⇒ Enhanced Security
The security features of RADWIN 1000/2000 include:
•RADWIN 1000/2000's AES 128-bit integrated advanced encryption support provides enhanced air interface security for carriers and private networks. It ensures user data protection with
one of the most sophisticated commercially available combined
encryption and authentication techniques, CCM/AES. This technique combines message authentication (preventing anti-spoofing and replay protection) with commercial encryption, and
complies with the IEEE 802.11i (phase iii) security recommendations.
CCM/AES uses a symmetric 128-bit encryption key (EK), and a
nonce, and provides both message encryption and authenticating signature. The nonce mechanism enables the receiver to
remember already received genuine messages and reject all
replayed messages.
•Initial encryption and authentication is based on a user-defined
master key (Link Password). While standard Wireless LAN
encrypts only the Ethernet Payload, the AES encrypts both the
source and destination MAC addresses.
RADWIN 1000/2000 User ManualVersion 2.2b1-4
RADWIN 1000/2000 Link Chapter 1
•In addition to normal login access, Read or Write Community
access is available at login
RADWIN 1000/2000 Link
The RADWIN 1000/2000 point-to-point solution is a wireless communication
link. Typically each side of the link is comprised of an Outdoor Unit (ODU)
and antenna and an Indoor Unit (IDU) or PoE device as shown in figure 1-
4 below.
The link is managed by the SNMP-based RADWIN Manager application.
The IDU and the ODU are connected by a CAT5e cable that carries the ser-
vice traffic and power.
Figure 1-4: Example of Link Architecture - System Components
The Radio Outdoor Unit (ODU)
The ODU is the radio transceiver of the RADWIN 1000/2000 system. It supports two radios for MIMO operation. It is available with an integrated
antenna (
antenna (
The ODU may be mounted on a pole or a wall, and connects to the IDU or
PoE device using a CAT5e cable.
Integrated Antenna ODU
Connectorized ODU
).
) or with connectors for an external
RADWIN 1000/2000 User ManualVersion 2.2b1-5
The Radio Outdoor Unit (ODU) Chapter 1
The ODU comes in two form factors as shown in figure 1-5 below:
a. Connectorized ODU Front
c. Integrated Antenna ODU
- Front
Figure 1-5: ODU Form Factors
•Integrated Antenna ODU
This ODU has an integrated 370mm (1.2ft) flat panel antenna, with
a gain of 23dBi. The ODU contains both the radio and the antenna
as a single unit housed in a weatherproof case.
b. Connectorized ODU Rear
d. Integrated Antenna ODU
- Rear
•Connectorized ODU
This ODU has 2x N-type connectors for connecting an external
antenna.
RADWIN 1000/2000 User ManualVersion 2.2b1-6
The Indoor Unit (IDU) Chapter 1
The ODU products available in release 2.2b are shown below:
Table 1-1: Available ODU Products - Release 2.2b
Description
Part Number
Form FactorFrequency Bands and Regulations
2050-0150Integrated antenna
2050-0250
Connectorized for external
antenna (2x N-type)
The only available external antenna is, single bipolar.
For further information, see page 4-20, Installing the Link: Step 4, Tx
Power and Antenna Settings.
The Indoor Unit (IDU)
The IDU has the service ports and provides aggregation of these services
towards the ODU that transports them over the air. The IDU also provides
power to the ODU.
The IDU-C is a carrier-class 19 inch, 1U unit, providing two Ethernet ports,
dry contact alarms and indication leds. It has two DC power feed connectors. An AC to DC converter is available for powering the IDU-C from an AC
source. The IDU-C is designed to be rack mounted.
One IDU-C product is available in release 2.2b:
Table 1-2: Release 2.1 IDU-C Products
FCC/IC5.725 – 5.850 GHz
FCC/IC4.940 – 4.990 GHz
Part Number
7200-20002
Ethernet
ports
Figure 1-6: IDU-C Front Panel
Power
Dual DC feed
-20 to -60VDC
Form
factor
19" 1U
RADWIN 1000/2000 User ManualVersion 2.2b1-7
Power Over Ethernet (PoE) Devices Chapter 1
Power Over Ethernet (PoE) Devices
The PoE device provides Ethernet service only, with power for the ODU. The
PoE device is extremely compact, having only two Ethernet ports and a
standard 3 pin male AC power socket.
Figure 1-7: PoE device - showing the radio Ethernet port
Antennas
An antenna is the radiating and receiving element from which the radio signal, in the form of RF power, is radiated to its surroundings and vice versa.
The antenna gain and transmitting power may be limited by country regulations.
The RADWIN 1000/2000 may be operated with an integrated antenna that
is part of the ODU unit, or with external antennas connected to the ODU via
N-type connectors. All cables and connections must be connected correctly
to reduce RF losses. The required antenna impedance is 50Ω.
The Integrated Antenna ODU is provided with 370 mm (1.2ft) flat panel
antenna, with a gain of 23dBi. The radio and the antenna are housed in a
weatherproof case as a single unit.
RADWIN 1000/2000 User ManualVersion 2.2b1-8
Antennas Chapter 1
Figure 1-8: ODU with integrated Flat Panel antenna
External antennas are available for the RADWIN 1000/2000 radios, varying
in operating frequencies, form factor, size and gain, dual or single polarization.
Flat Panel Antennas
The Flat Panel antenna shown in figure 1-9 below has an integrated or
external configuration:
Integrated or External
1.2ft Flat Panel Dual Polarization
Frequency
Gain
Size1.2 x 1.2 ft / 371x371 mm
Beam Width
Figure 1-9: Flat Panel Antenna
4.9 - 5.875 GHz (Ext)
4.9 – 6.0 GHz (Int)
External
22.5 dBi at 4.9 – 5.25 GHz
23.5 dBi at 5.25 – 5.875 GHz
Integrated
21 dBi at 4.9 – 5.0 GHz
22 dBi at 5.0 – 5.15 GHz
23.5 dBi at 5.15 – 5.725 GHz
24 dBi at 5.725 – 6.0 GHz
H, V: 9° (Ext)
H, V: 8° (Int)
RADWIN 1000/2000 User ManualVersion 2.2b1-9
RADWIN Manager Chapter 1
Parabolic Dish Antennas
External
2ft Dish Dual Polarization
Frequency
Gain28 dBi
Diameter2 ft / 620 mm
Beam WidthH,V: 5.6°
5.150 - 5.875 GHz
4.900 – 5.850 GHz
Figure 1-10: External Antennas - Parabolic Dish
See the RADWIN products catalog for RADWIN offering of external antennas. External antennas are also available from authorized antenna vendors.
RADWIN Manager
The RADWIN Manager is an SNMP-based management application which
manages a complete link over a single IP address. It can also manage each
side of the link separately.
The RADWIN Manager application facilitates installation and configuration
of the link between the ODU units. The intuitive, easy-to-use RADWIN Manager has a graphical Microsoft Windows interface, and can be run locally
and remotely.
The RADWIN Manager provides:
•Installation Wizard
•On-line monitoring of air interface quality allowing the administrator
to monitor the service and status of each link
•On-line monitoring of equipment alarms and QoS
•Local and remote loopback testing
•Configuration settings
•On-line user manual and help files
•Link Budget Calculator for calculating the expected performance of
the RADWIN 1000/2000 wireless link and the possible service configurations for a specific link range.
The RADWIN Manager can easily be integrated with any NMS system.
RADWIN 1000/2000 User ManualVersion 2.2b1-10
Accessories Chapter 1
Figure 1-11: RADWIN Manager screen
Accessories
RADWIN provides a variety of accessories to support the RADWIN 1000/
2000 system:
•PoE devices
•AC Power Adaptor
•External Lightning Protection Unit
•Cables to connect the various system elements
Documentation set supplied with RADWIN 1000/2000
The technical documentation supplied with a RADWIN 1000/2000 includes
the following items:
•A Quick Start Guide for experienced installers
•A full User Manual - the document which you are reading
RADWIN 1000/2000 User ManualVersion 2.2b1-11
How to Use this Manual Chapter 1
How to Use this Manual
This User Manual is divided into functionally distinct chapters reflecting the
activities required to set up a RADWIN 1000/2000. The division is shown in
the following table:
Chapter/
Appendix
SubjectAudience
2Site Preparation
3Hardware Instal-
lation
4Link Installation:
The RADWIN Manager
5Configuring the
Link
6Site Configuration
7Monitoring and
Diagnostics
ATechnical Specifi-
cations
BWiring Specifica-
tions
Site survey team
Field technician
Installation technician
Installation technician, System manager
Installation technician, System manager
Installation technician, System manager
Installation technician, System manager
Installation technician
CPole and Wall
Installation
DLink Budget Cal-
culator
ELightning Protec-
tion and Grounding Guidelines
FMIB Reference
GExternal Alarms
Specification
HCombo Configura-
tion Tool
A Little Terminology
In the field, a link typically has a local or headquarters site as for example in
figure 1-2 above. Here the service provider is the local or headquarters
site. The service recipient is the remote site.
Installation technician
Installation technician
Field technician
System manager
Installation technician, System manager,
Field technician
Installation technician
Where the link is completely internal to a corporation, the choice of the local
and remote is just a matter of convenience.
RADWIN 1000/2000 User ManualVersion 2.2b1-12
A Little Terminology Chapter 1
link
A
In Broadband Wireless terminology, the local and remote sites are some-
times referred to as “near” and “far”, “HQ” and “remote” and so on.
The site which is closer to the network core (often the local site) will be
referred to as
end user, as
This choice is application-neutral and will be used throughout the manual
both to describe the sites and their names as in the examples.
then, consists of two
site A
site B
, and the opposite side of the link, usually closer to the
.
sites
.
The link is configured and managed using a PC, the
connected to site A. (The precise requirements for the managing computer
are set out in chapter 3, Hardware Installation).
RADWIN 1000/2000 supports three connection methods for the managing
computer:
•
Local
- a direct peer to peer connection between the Ethernet ports
on the managing computer and the IDU or PoE device. Local connection is always read-write.
•
Network
device belong to a LAN and communicate through a router or hub
•
Over-the-air
air interface
The managing computer may be connected to the link through an IDU or a
PoE device. In what follows, where ever we refer to an IDU it includes PoE
devices unless stated otherwise. Typically, if we need to refer to an IDU as
such, we will use a model name such as IDU-C.
- the managing computer and the site A IDU or PoE
- the managing computer connects to site B via the
managing computer
RADWIN 1000/2000 User ManualVersion 2.2b1-13
Conventions Used in this Manual Chapter 1
Conventions Used in this Manual
Notifications
Notifications consist of Notes, Cautions and Warnings.
The purpose of a Note is to
•Draw your attention to something that may not be obvious or coun-
Note
ter-intuitive
•Emphasize a special feature or peculiarity of the RADWIN 1000/2000
•Offer an external reference for additional information
•Add a caveat that would not qualify as a full Caution or Warning (see
below)
•Provide additional background to what follows
•Offer a recommendation
•Highlight an indication of something to watch out for
•Advise you if an action has “side effects” i.e. it may disturb something
else that would be best left undisturbed
Caution
Warning
•Remind you of something that should be kept in mind
A Caution is a notification of risk of damage to equipment or of service
degradation
A Warning is a notification of risk of danger to persons operating near the
equipment
Typographical conventions
General
Where a term is defined or introduced for the first time, it is shown in Boldface. You will have noticed this usage in the Terminology section above.
Software
The RADWIN Manager is a Microsoft Windows application following the user
interface conventions of familiar Microsoft Windows programs.
We would describe the chain of menu commands indicated in the following
screen shot, like this:
Tools|Active Alarms|1 A
using Boldface for the menu labels and vertical bars to separate them.
RADWIN 1000/2000 User ManualVersion 2.2b1-14
Windows Terminology Chapter 1
Similarly, mouse click items will be referred to like this:
“Click Next to continue.”
(A mouse click always uses the left mouse button unless stated otherwise.)
Windows Terminology
Look at figure 1-11 above. The main application display which you see
consists of a frame-window with a menu bar, system icons and content. It
will be referred to as a window, the main window or the Manager window depending on context.
The top line of icons is the tool bar, and provides part of the menu bar
functionality with a mouse click.
At the bottom of the window is the status bar, a line of icons and text
boxes.
The central part of the main window consists of several panes: On the
right, there are Radio Interference, Ethernet Service and the Frequency
panes. The left hand pane (with the blue background) is split into three
sub-panes.
If you click Site A or Site B in the tool bar, you will be offered another window, which in turn displays on of several panels depending on which function you choose.
RADWIN 1000/2000 User ManualVersion 2.2b1-15
Windows Terminology Chapter 1
Figure 1-12: Site Configuration window with open Management panel
RADWIN 1000/2000 User ManualVersion 2.2b1-16
Planning the Link Site
Overview
Link site planning consists of a set of surveys, which must be carried out
before any equipment is brought to the site. If for some reason, the outcome of any of these surveys is negative, site re-location will need to be
considered.
A Site Survey consists of three stages:
1. Preliminary survey - The proposed link is analyzed in the office using a
topographic map.
2. Physical survey - The locations of the RADWIN 1000/2000 indoor and
outdoor equipment are determined on-site.
Chapter 2
Site Preparation
3. Radio Frequency (RF) survey - It is recommended that the installation
area be scanned with a spectrum analyzer, to identify RF interference so
as to determine a clear channel for RADWIN 1000/2000 installation (on-site).
The Site Survey
Introduction
RADWIN 1000/2000 wireless links must be planned before installation. The
designated installation site must be appraised to determine that the wireless system is able to operate efficiently and provide connectivity without
signal degradation.
RADWIN 1000/2000 offers a wide operating frequency range. A free frequency channel must be determined within the operating range, for optimum performance.
Recommended Equipment
Stage 1: Preliminary Survey
•Topological map of the area
RADWIN 1000/2000 User ManualVersion 2.2b2-1
Stage 1: Preliminary Survey Chapter 2
•Urban map of the area
•Compass
Stage 2: Physical Survey
•100 meter tape measure
•Ohmmeter, to check ground connection
•Binoculars
•Map
•Digital camera
•Paper, pencil, and a clipboard
•GPS device (optional)
•Compass (optional)
Stage 3: RF Survey
•Spectrum Analyzer with Max Hold function and screen capture facility that can store multiple images, for documentation purposes
•RF accessories (connectors and cables)
•Communication devices (for example, cellular phones, or a set of
walkie-talkies)
Stage 1: Preliminary Survey
A preliminary survey is necessary before visiting potential installation sites.
As much detail as possible should be obtained about the two designated
ODU installation sites and the area between them.
¾ To perform a preliminary survey:
1. Mark the two designated installation sites on a topographic map of the
area.
2. Measure the distance between the sites; check that it is within the specified range of the RADWIN 1000/2000.
3. On the urban map, check for developed areas situated between the two
installation sites. Pay attention to these areas when performing the physical site survey; there may be tall buildings, RF towers, or transmitters,
which could cause interference to the link.
4. Check the area between the two sites for obstructions such as:
•High ground - hills or mountains
•Lakes or large bodies of water. Water has a reflection effect on RF
signals like a building. This type of reflection causes the received
amplitude to be reduced. As a rule of thumb, the presence of a large
body of water between the link sites may double the required
antenna height.
5. Determine and record the compass bearings between both ODUs, relative to north.
6. If there are obstructions between the two sites, calculate the Fresnel
Zone (see appendix D for details).
RADWIN 1000/2000 User ManualVersion 2.2b2-2
Stage 2: Physical Survey Chapter 2
7. If the site chosen does not meet requirements, consider alternative sites.
8. Use the Link Budget Calculator (on the CD supplied with the RADWIN
1000/2000 or using the RADWIN Manager) to determine the expected
performance.
Stage 2: Physical Survey
The physical site survey reviews the environment of the proposed RADWIN
1000/2000 installation location, to ensure that the link sites are suitable for
the wireless network. The results of the physical site survey should be
recorded.
It is advisable to go on a clear day, so you can more easily see any
obstructions between the two sites.
Note
¾ To perform a physical survey:
Note
1. From the compass readings taken in the preliminary survey, find the azimuth (horizontal position) that the ODU should face towards the second
ODU.
2. Using binoculars, locate any obstructions such as tall trees, high buildings, hills or mountains. Look for other RF towers between the two sites.
Mark the locations of the obstructions on the map.
3. Determine the location for the ODU (having regard for existing rooftop
installations and tower space). It should be above any obstructions, considering the Fresnel zone (see appendix D).
4. If you need to install the ODU on a tower, make sure that the tower is far
away from overhead electric power lines.
5. Determine a location for the indoor equipment; it should be as close as
possible to the ODU. At an existing site, there is probably an equipment
room with cable-routing channels.
The IDU - ODU cable length limit is 100m, in accordance with IEEE 10/
100BaseT standards.
6. Measure and record the path length of the cable from the ODU position
to the indoor equipment room.
7. Determine the ground and lightning connection points of the installation.
The RADWIN 1000/2000 ODU and IDU must both be grounded.
8. Using the Ohmmeter, measure and record the resistance of the required
installation to the grounding point. The resistance must be less than 1O
ohm.
RADWIN 1000/2000 User ManualVersion 2.2b2-3
Additional Outdoor Site Requirements Chapter 2
9. Review the results of the physical site survey. Decide if the site is suitable
for the RADWIN 1000/2000 wireless network installation.
•If the site is suitable, continue with stage 3, the RF survey
•If the site is not suitable, survey another site
Additional Outdoor Site Requirements
The ambient outdoor operating temperature should be -35 to 60°C (-31 to
140°F).
Additional Indoor Site Requirements
The following requirements guarantee proper operation of the system:
•For IDU-C units, allow at least 90 cm (36 “) of front clearance for
operating and maintenance accessibility. Allow at least 10 cm (4 “)
clearance at the rear of the unit for signal lines and interface cables
•The ambient operating temperature should be 0 to 50°C (32 to 122
°F) at a humidity of up to 90%, non condensing
Stage 3: RF Survey
The RF survey examines the wireless environment of the RADWIN 1000/
2000 installation site, to determine whether there are available channels
within the RADWIN 1000/2000 operating frequency band. An RF survey is
performed using a spectrum analyzer.
It is advisable to familiarize yourself with the spectrum analyzer before
going out on site, specifically the Max Hold and Marker functions.
You should perform the RF survey at both proposed link sites.
The survey should be carried out during a busy time of day, to best judge
the worst-case radio interference. Allow 2-4 hours duration for a good RF
survey.
It is possible to install the RADWIN 1000/2000 link and use the RADWIN
Manager to find a clear channel. Each frequency channel can be evaluated
in turn. Achievement of a clear channel is indicated by the Quality bar on
Note
the Channel Setting window (see figure 4-13) becoming green.
RADWIN 1000/2000 User ManualVersion 2.2b2-4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.