RADWAG WTC series, LW series, WTC6 C1/LW, WTC15 C1/LW, WTC30 C1/LW User Manual

...
Page 1
USER MANUAL
Counting scales – WTC/LW series
MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMEN TS
RADWAG 26 – 600 Bracka 28 Street, POLAND Radom, phone+4848 3848 800, phone/fax +4848 385 00 10, Sales Department +4848 366 80 06
www.radwag.com
MAY 2007
Page 2
TABLE OF CONTENTS
1. INTENDED USE - MAIN FUNCTIONS.......................................................3
2. CONSTRUCTION.......................................................................................3
2.1. Indicator...........................................................................................................3
2.2. Keyboard and display window.........................................................................4
2.3. Additional markers...........................................................................................4
2.4. Function buttons and functions........................................................................5
3. OPERATION...............................................................................................6
3.1. Tarring.............................................................................................................6
3.2. Zeroing............................................................................................................6
4. COUNTING PIECES WITH SAME UNIT MASS........................................7
4.1. Single piece mass is known ............................................................................7
4.2. By determination of single unit mass...............................................................8
5. SUMMING OF WEIGHING WHILE COUNTING PIECES..........................9
6. PROGRAM VALUE WHILE COUNTING PIECES ...................................11
7. ACCURACY OF THE SCALE...................................................................12
8. BACKLIGHT..............................................................................................13
9. BATTERY CHARGING.............................................................................13
10. TECHNICAL PARAMETERS..................................................................14
11. MESSAGES ON SCALE DISPLAY........................................................14
- 2 -
Page 3

1. INTENDED USE - MAIN FUNCTIONS

Scales series WTC /LW are designed for counting pieces with same unit mass. Counting process can be realized as:
Specification of sample mass (one piece)  Calculation of sample mass from some determined amount of
samples on the weighing pan
TARE functions allows for determination of net mass of measured loads – tare range equal to max capacity of the instrument – Max.
Functional possibilities
Setting alarm function for counting (threshold)
Change of scale readability
Totalizing in counting pieces mode
Counting pieces

2. CONSTRUCTION

2.1. Indicator

Fig. 1 – Indicator construction
1 Fixing screws 7 Electronic PCB 2 Accumulator cover 8 Cover 3 Accumulator 9 Keyboard 4 Hausing 10 Display 5 Power supply socket 11 Tensometer connector 6 Press down plate 12 RS 232 connector
- 3 -
Page 4

2.2. Keyboard and display window

Fig. 2 – buttons and displays
Scales are equipped with three displays: mass, piece mass, quantity of pieces, and functional keyboard with numeric and function keys.

2.3. Additional markers

Character Description
Zero indication of scale
Stable weighing result
TARE button applied – net indication Display indicates total quantity of pieces (sum) or function
of summing details is active Scale powered from mains Power supply from battery is low (please charge the
battery)
- 4 -
Page 5

2.4. Function buttons and functions

1.
2.
3.
4.
5.
6.
7.
8.
9.
Turn on/off
Confirm the quantity of pieces as a standard mass
Pressing this button, will cause the display to show in field WEIGHT, message “total” – display of total sum of counted pieces
Deleting sum of counted pieces
Confirms mass of single unit mass
Possibility of setting a threshold for counting pieces mode (after crossing this threshold, scale generates beep signal)
Deleting the value
TARE button (for determination of net mass)
ZERO button (setting zero point of the scale), switching on/off scale’s backlight
10.
11.
Summing of following weighing for counting mode or change of readability of the scale
Decimal point – for insertion of single unit mass value.
- 5 -
Page 6

3. OPERATION

3.1. Tarring

Place the package of the good(s) on the weighing pan. After stabilization of weighing result, please press button TARE. Display will show ZERO indication. Lower part of the display WEIGHT, the marker of tare application will be visible.
Fig. 3 – Tarring of scale indication
After taking the load off the weighing pan, the display will show mass indication with negative (minus) sign in front of mass.
Press button TARE, so that indication goes back to zero. Tare function will be canceled automatically. Tarring is available in all weighing range of the scale.

3.2. Zeroing

It is available in range up to +/- 2% of maximal capacity of the scale.
Procedure:
If the scale indication is lower than 2% Max
Press button ZERO to zero indication
Markers of zero indication and stable result are visible
Fig. 4 – zeroing of scale indication
- 6 -
Page 7
After taking the load off the weighing pan, mass indication with negative (minus) sign is visible on the display
Press button ZERO, indication will go back to zero.

4. COUNTING PIECES WITH SAME UNIT MASS

4.1. Single piece mass is known

In case unit mass of the counted objects is known, counting mode can be realized in following way:
Place on the weighing pan a container in which the pieces will be
counted, and press button TARE
Using numeric keyboard, please insert unit mass. Use decimal point.
Place counted pieces on the weighing pan of the scale.
Press button
Display described as COUNT will show quantity of pieces
add following pieces, their quantity will increase automatically.
Fig. 5 – counting pieces
take the weighed elements off the pan. In order to perform
another weighing / counting, insert another unit mass and confirm it.
Going back to weighing mode is possible after pressing
button for CANCELING
- 7 -
Page 8

4.2. By determination of single unit mass

If unit mass of counted objects is not known, please act as described below:
Place a container for counting pieces on the weighing pan, and press
button TARE
Using numeric keyboard of the indicator, insert quantity of pieces
(reference mass), which will be used to calculate single piece mass
CAUTION: reference mass has to be natural number.
Place counted pieces on the weight pan of the scale
Press button
Display described as UNIT WEIGHT will show unit mass of a sample
Display described as COUNT will show quantity of details, used for
calculation of unit mass
Add another details, their quantity will increase automatically.
Fig. 6 – counting pieces 2
take the weighed elements off the pan. In order to perform another
weighing / counting, insert another unit mass and proceed as described above.
Going back to weighing mode is possible after pressing
button for CANCELING
- 8 -
Page 9

5. SUMMING OF WEIGHING WHILE COUNTING PIECES

While counting pieces, it is possible to use summing function. Please follow below procedure:
1. Start counting pieces as described in points 4.1. or 4.2.
2. when scale shows quantity of pieces, press button PLUS
3. for a moment, quantity of pieces visible in display window COUNT with be invisible, it is a signal that value has been accepted. At the same time, display described as WEIGHT will show marker of summing: (M
+
)
Fig 7 – function for summing details
4. take the counted objects off the weighing pan (leave the container),
scale will go back to zero indication
5. put into the container another details, and press button PLUS
6. if the package needs to be changed, put it on the weighing pan, and press button TARE. If the same package is still in use, and it is taken off the pan together with the counted details, please tare the empty package again, after placing it on the weighing pan of the scale.
7. In order to see quantity of summed details please
press button
8. The display with show headline of the operation, quantity of summed weighing (in field UNIT WEIGHT) and total quantity of details (in field COUNT).
- 9 -
Page 10
Fig. 8 – view of sum from a few weighings
9. Continuous summing of weighing is possible after pressing button
10. Proceed according to points 5 – 7
CANCELING SUM OF COUNTED DETAILS
the moment, the sum of counted details is visible ( please see drawing no. 8), and press button:
Scale will go back to weighing mode, sum marker will be no longer visible (marker over M
+
will disappear).
Fig. 9 – cancelling sum of counted details
- 10 -
Page 11

6. PROGRAM VALUE WHILE COUNTING PIECES

While counting pieces mode, control of quantity takes place in visual way – user should observe display status. For fast processes of quantity building, it is often required to have some limited quantity which can not be exceeded in one package.
Software of the sale allows for insertion of such limited quantity of pieces, which exceeding causes sounding of beep signal.
Procedure:
Using numeric keyboard of the scale, insert value of the threshold for control of counted details:
Fig 10 – numeric functional keyboard of the scale
Press button
Inserted value will be stored and immediately switched off, display will
go back to previous state
If while counting pieces, quantity of pieces is exceeded, scale will start to generate ,,beep” sound
Signal will be switched off, immediately after having appropriate quantity of pieces (below the threshold limit).
CAUTION:
Value of the threshold can be set either in weighing mode or in counting d etails mode.
in order to switch off control of weighed details, insert 0 (zero – numeric keyboard) and press button
- 11 -
Page 12

7. ACCURACY OF THE SCALE

after switching the scale by pressing button ON/OFF, scale performs auto-test, visible on the display of the instrument. While this process, press button
After cycle completion, scale status will look as below:
Fig 11 – choice of readability of the scale
Press button PLUS multiple times, choose readability of the scale
Confirm set value by pressing button TARE,
Scale will go back to weighing mode.
- 12 -
Page 13

8. BACKLIGHT Switching on backlight :

Press and hold button [ZERO] for 3 seconds, on the display described as COUNT backlight parameter value will be displayed.
Below values are accessible
o bl OFF (backlight off) o bl ON (backlight on) o bl Aut (automatic control, active only when indication changes
and for the next 3 seconds after getting stable.)

9. BATTERY CHARGING

Each scale is equipped with internal rechargeable battery. When the marker over the battery icon is visible, please charge the battery.
Fig 12 –
battery charging
Connect the power adapter to indicator’s socket – process of battery charging will begin. (signaled by CHARGE STATUS diode). During charging, it is possible to operate the scale in normal way. When the battery is charged the marker will be off. If the voltage level is to low for operation, it should be replaced. Open the hausing of the indicator – see fig. 1. Disconnect the old accumulator and replace it with a new one of the same type.
- 13 -
Page 14

10. TECHNICAL PARAMETERS

Scale type:
Maximal capacity. Readability Tare range Pan size Working temperature Power supply Display
WTC
6 C1/LW
6 kg 15 kg 30 kg 60 kg
0,2 g 1 g 1 g 2 g
-6 kg -15 kg -30 kg -60 kg
Accumulator and 230V AC / 9V DC, 800mA
WTC
15 C1/LW
290×360 mm
-10° - +40° C
LCD × 3 szt.
WTC
30 C1/LW
WTC
60 C1/LW
WTC
Scale type:
60
C2/LW
Maximal capacity. Readability Tare range Pan size Working temperature Power supply Display
60 kg 150 kg 300 kg 150 kg 300 kg
2 g 10 g 10 g 10 g 10 g
-60 kg -150 kg -300 kg -150 kg -300 kg
Accumulator and 230V AC / 9V DC, 800mA

11. MESSAGES ON SCALE DISPLAY

WTC
150
C2/LW
WTC
300
C2/LW
WTC
150
C3/LW
WTC
300
C3/LW
400×500 mm 500×700 mm
-10° - +40° C
LCD × 3 szt.
FULL – exceeded the limit of counted pieces (over 99 999) Err No – incorrect data format while inserting reference mass (inserted value
is not natural number)
OVER – scale overloaded over the maximal capacity
- 14 -
Page 15
MANUFACTURER
OF ELECTRONIC WEIGHING INSTRUMENTS
ZAKŁAD MECHANIKI PRECYZYJNEJ ,,RADWAG”
26 – 600 Radom, Bracka 28 Street
POLAND
phone +48 48 38 48 800, phone./fax. + 48 48 385 00 10
www.radwag.com
- 15 -
Loading...