ENG
Mounting instructions
Likoma V E
FR
NL
Instruction de montage
Montagehandleiding
Likoma V E comes in four different nishes :
Likoma V E existe en 4 nitions :
Likoma V E bestaat in 4 afwerkingen :
SG = sand - sable - zand
WG = white - blanc - wit
GG = granite - granit - graniet
BG = black - noir - zwart
B = height - hauteur - hoogte
C = lenght - longueur - lengte
n = nominal heat output - puissance nominative - nominatieve afgifte
e = effectif heat output - puissance effective - effectieve afgifte
type B C
LIV900400ELGG 900 400 11,00 600 390
LIV900400ELSG 900 400 11,00 600 390
LIV900400ELWG 900 400 11,00 600 390
LIV900400ELBG 900 400 11,00 600 390
LIV1500400ELGG 1500 400 19,00 1000 650
LIV1500400ELSG 1500 400 19,00 1000 650
LIV1500400ELWG 1500 400 19,00 1000 650
LIV1500400ELBG 1500 400 19,00 1000 650
LIV1800400ELGG 1800 400 22,00 1200 780
LIV1800400ELSG 1800 400 22,00 1200 780
LIV1800400ELWG 1800 400 22,00 1200 780
LIV1800400ELBG 1800 400 22,00 1200 780
LIV1500600ELGG 1500 600 27,00 1500 975
LIV1500600ELSG 1500 600 27,00 1500 975
LIV1500600ELWG 1500 600 27,00 1500 975
LIV1500600ELBG 1500 600 27,00 1500 975
LIV1800600ELGG 1800 600 32,00 1800 1170
LIV1800600ELSG 1800 600 32,00 1800 1170
LIV1800600ELWG 1800 600 32,00 1800 1170
LIV1800600ELBG 1800 600 32,00 1800 1170
weight
poids
gewicht
[kg]
Dimensions / Afmetingen
in / en mm
output
puissancevermogen
[watt]
n e
stock Radson
1

ENG
INSTALLATION INSTRUCTIONS
Electrical appliance
STANDARDS
The electrical appliance is conform to the standards
EN 60.335-1 and 60.335-2-30.
The heating appliances are double insulated - Class II and
splash resistant. The appliances also comply with European
directive 2004/108/EC (CE Marking on all appliances).
POSITIONING
•
The appliances must be positioned
standards in force in that regard.
• The appliance may be positioned in volume 2 of the bathroom, insofar as no operating controls (button, switch,
etc.) are in reach of persons in the bath or under the
shower.
• The bottom of the control must be a minimum of 150
mm above oor level.
• The appliance must be positioned a minimum of 50 mm
from the wall and not be located underneath an electric
socket.
WARNING: For the safety of young children it is advisable to
position the appliance in such a way that the lowest heated
part is a minimum of 600 mm above oor level.
according to the
CONNECTION
• The appliance is designed for single-phase 230 V ~ 50 Hz.
• The appliance must be connected to the electrical
network, by means of the original power cable, via a wall
socket (not with a plug and socket!) located behind the
appliance and a minimum of 250 mm above oor level.
• Neutral: grey wire - Phase: brown wire - Control wire (pilot
wire): black wire (if this control/clock-function is present).
Use of the control wire makes it possible to decrease the
temperature if connected to an adapted clock. Open end
means comfort temperature, connected to phase means
reduced temperature. The wire may never be connected
to the earth and must be isolated if this function is not
used.
• If the power cable is damaged it must be replaced with
an appropriate cable. This replacement may only be
carried out by the manufacturer, its after sales service or
equivalent qualied persons, this is to prevent any danger.
• This appliance is lled with a specic amount of heat
conducting uid (not applicable for the models Likoma
E, Amirante E and Cosmoledo E). If it has to be opened to
carry out repairs then this must only be carried out by the
manufacturer, the manufacturer’ s after sales service
provider, who must be contacted in the event of a leak of
the heat conducting uid.
• According to the standards in force a separating
omnipolar switch must be provided.
The distance between the contacts will be a minimum of
3 mm.
• If the appliance is installed in a bathroom or shower room
it must be safeguarded with a differential switch with a
maximum of 30 mA.
• When disposing of this appliance, the heat conducting
uid must be removed by certied subcontractors (not
applicable for the models Likoma E, Amirante E and
Cosmoledo E).
FIXING
“For the correct installation of the appliances it is essential
that the xing of the appliance is carried out in such a way
that it is suitable for intended use AND predictable misuse.
A number of elements need to be taken into consideration
including the xing method used to secure the appliance to
the wall, the type and condition of the wall itself, and any
additional potential forces or weights, prior to nalising
installation.”
MISCELLANEOUS
The appliances are not designed for use by persons (and
children) with physical, sensory or mental disabilities or
persons with a lack of experience or knowledge, unless
under the supervision of, or have received the necessary
instructions regarding the use of the appliance, from
a person responsible for their safety. Children should
be supervised to ensure that they do not play with the
appliance.
WARNING: In order to avoid
overheating, do not cover the
appliance. “Do not cover” means that
the appliance must not be used for
drying clothes, for example, by placing
them directly on the appliance.
WASTE DISPOSAL ACCORDING TO THE WEEE DIRECTIVE (2002/96/EC)
The symbol on the product label indicates that the product may not be handled as domestic waste, but must be sorted separately.
When it reaches the end of its useful life, it shall be returned to a collection facility for electrical and electronic products.
By returning the product, you will help to prevent possible negative effects on the environment and health to which the product
can contribute if it is disposed of as ordinary domestic waste. For information about recycling and collection facilities, you should
contact your local authority/municipality or refuse collection service or the business from which you purchased the product.
Applicable to countries where this Directive has been adopted.
2