Radio Systems GPI12, HUB24, HUB32, GPI24, MiniTie12-4 Technical Manual

...
Page 1
Technical Manual for Hubs
Updated: 09/07
Page 2
Table of Contents
StudioHub+ Master Pin Out Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HUB16-DC & HUB8-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 & 8 Channel Break-Out Hubs with DC-Link
HUB18-DC
18 Channel Break-Out Hub with DC-Link
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HUB32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32 Channel Break-Out Hub
HUB36-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36 Channel Break-Out Hub with DC-Link
HUB12
12 Channel Audio Card Break-Out Hub (rack mount)
HUB24
24 Channel Thru-put Hub (rack mount)
GPI12/24
12/24 Channel GPI Relay Hub (rack mount)
MiniTie12-4
4 wire / 12 channel Tie-Line Hub (mini wall mount)
MiniTie24-4
4 wire / 24 channel Tie-Line Hub (mini wall mount)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
3
4
5
6
7
8
9
bk
bk
MiniTie6-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 wire / 6 channel Tie-Line Hub (mini wall mount)
MiniTie12-8
8 wire / 12 channel Tie-Line Hub (mini wall mount)
Tie12-4DC
4 wire / 12 channel Tie-Line Hub with DC-Link
Tie24-4DC
4 wire / 24 channel Tie-Line Hub with DC-Link
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tie12-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 wire / 12 channel Tie-Line Hub
Tie24-8
8 wire / 24 channel Tie-Line Hub
Patch44
44 Channel Patch Panel
Patch48
48 Channel Patch Panel
Sum8, Sum4
Active Summing Amp Hubs
DA12-DC, DA6-DC
Active Distribution Amp Hubs with DC-Link
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
bl
bl
bm
bm
bn
bn
bo
bp
bq
br
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
Page 3
White/Orange
L+ / AES+
Orange/White
L- / AES-
White/Green
R+
White/Blue nc
Green/White R-
White/Brown 15V-
Brown/White 15V+
Blue/White GND
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
cc
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
Channel
L+ / AES+ L- / AES­R+ R­nc GND 15V­15V+ Shield Shield
Wht/Org Org/Wht
Wht/Grn Grn/Wht Wht/Blu Blu/Wht Wht/Brn Brn/Wht
Wht/Slt Slt/Wht
1 2 3 6 5 4 7 8
Shield Shield
3 4 5 6
1 2 7 8 9
10
Color Pair RJ-45 Pins 110 Pins
StudioHub+ Pinout Chart
TR+
TR-
R+
R­n/c n/c n/c n/c
x x
Ethernet
c
c
c
c
c
c
c
c
c
c
c c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c c
c
c
c
c
c
c
c
c
c
c
c c
c
c
c
c
c
c
c
c
c
c
c c
Data Pinout T568B
RJ-45 Compatible
white/blue
blue/white
white/orange
orange/white
white/green
green/white
white/brown
brown/white
Telco Pinout
RJ-11 Compatible
white/blue
blue/white
n/c
n/c
white/orange
orange/white
n/c
n/c
3
6
7
8
5
4
1
2
3
6
7
8
5
4
1
2
®
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
2
Page 4
For Assys:
HUB16-DC
HUB8-DC
Rev: 01/05
StudioHub+ Model HUB16-DC and HUB8-DC
Engineered for StudioHub+ and High-Speed Ethernet Connectivity
Model HUB16 pictured
Also available as hub 8 channel - model Hub8
Product Key Name HUB16 / HUB8 Mount Hub (3 r.u.)
Channels 16 / 8
CAT-5 Pairs 4 (all)
Power Link yes
Connectors 2 RJ-45 & 110
Versions Full Hub/Half Hub/Board Only
General
Each of 16 (or 8 if ordered in the Hub model) Hub channels consists of an RJ-45 input connector in parallel with an output RJ-45 connector and a 110-style punch connector. Each channel carries a stereo balanced audio pair, or balanced digital audio signal, and an optional +/- 15 DC voltage. Equipment cabling may also be punched down to the inline 110 connector.
DC Power
If using any StudioHub+ "DC-Link" accessories, plug a StudioHub +/- 15 volt power supply into the power supply connector. Both Hub LED s will illuminate. Insert both power jumpers and the DC ground jumper on only the circuits that utilize a powered accessory (e.g. MatchJack, mic preamp, etc.).
Grounding Information
Cable and connector shields are contiguous from each individual hub channel (input to output) but are normally isolated from other channels.
To use the hub as a common ground point, insert the jumper below each left-hand RJ-45 that you want common to the chassis ground. If you have a StudioHub+ 15V power supply connected to the hub, and JU-33 is jumpered, chassis ground, electrical ground, and shield are common.
JU33
Insert jumper under any
right-hand jack to
connect that channel s
shield to the common
shield bus
Insert jumper under any
left-hand jack to connect
that channel s shield to
the common chassis
ground
Install both DC jumpers to activate StudioHub+
DC-Link connection to
provide +/-15V DC to
any powered accessory
Note: All 3 of these
jumpers must be inserted
for any channel that is
powering a remote DC-
Link device (e.g.
StudioHub+ MatchJack
or Pre-Amp)
This jumper connects the
channel to the common
power ground bus when
installed. Required for
DC-Link operation.
Note: This jumper must
be removed for KVM
extender links and other
data devices that use
CAT-5 wire #4 (blu/wht)
1/2 Amp
Supply Ground
auto-reset fuse
8
7 6 5
4 3 2
1
RJ-45-1
JU34
J2
Power
R2
1/2 Amp
auto-reset fuse
R1
15v-
JU2
JU1
Shield
Hub Chassis Ground
15v+
8
7 6 5
4 3 2
1
RJ-45-2
Radio Systems, Inc. (856) 467-8000
JU4JU3
Power Supply Shield
Slt/Wht Shd
Wht/Slt Shd
Brn/Wht + 15V
x 16
Wht/Brn - 15V
Grn/Wht R-
or 8
Wht/Grn R+
Org/Wht L-
Wht/Org L+
Blu/Wht G
Wht/Blu n/c
J4
J3
110 Connector
+/-15V external power
supply main and loop-
thru jumpers
10 pin 110-style connector
provides access to all 4 CAT-5
601 Heron Drive
Logan Twp., New Jersey 08085
Insert jumper to connect
to the power supply
shield
LED s indicate presence of
+/- 15V DC
pairs and cable shield
3
Page 5
For Assy: HUB18-DC Rev: 01/05
StudioHub+ Model HUB18-DC
Engineered for Break-Out Harnesses
General
Each of 18 Hub channels consists of two 2-pin mini-Amp input connector in parallel with an RJ-45 connector and 100­style punch-down connector. Each channel carries a stereo balanced audio pair, or balanced digital audio signal. Custom length and configuration harness cables must be factory ordered to interconnect the Hub to various consoles, audio routers and engines or multi-channel Digital Audio Workstations.
DC Power
If using any StudioHub+ "DC-Link" accessories, plug a StudioHub+ +/- 15 volt power supply into the power supply connector. Both Hub LED s will illuminate. Insert both power jumpers and ground jumper only on only the circuits that utilize a powered accessory (e.g. MatchJack, mic preamp, etc.).
Grounding Information
RJ-45 connector shields may be isolated from each other or optionally connected to each other or to the hub chassis by inserting jumper by each connector.
To use the hub as a common ground point, insert a jumper above any left-hand RJ-45 for any channel that you want to be in common with the chassis ground. If you have a StudioHub+ 15V power supply connected to the hub, to connect a channel to the power supply shield, insert a jumper above any right-hand RJ-45 of that channel.
Name HUB18-DC
Mount Hub (3 R.U)
Channels 18 CAT-5 Pairs 2 (pins - 1,2,3&6) Power Link yes Connectors Mini-amp & RJ-45
Versions Full Hub
Product Key
10 pin 110-style
connector provides
access to all 4 CAT-5
pairs and cable shield
Upper and lower 2-pin
mini-amp connectors
wire to source gear audio
I/O via certain harness
cables
Note: All 3 of these
jumpers must be inserted
for any channel that is
powering a remote DC-
Link device (e.g.
StudioHub+ MatchJack
or Pre-Amp)
Install both DC jumpers to activate StudioHub+
DC-Link connection to
provide +/-15V DC to
any powered accessory
This jumper connects the
channel to the common
power ground bus when
installed. Required for
DC-Link operation.
Note: This jumper must
be removed for KVM
extender links and other
data devices that use
CAT-5 wire #4 (blu/wht)
LED s indicate presence of
+/- 15V DC
+/-15V external power
supply main and loop-
thru jumpers
8 7 6 5 4 3 2 1
Shield
RJ- 45
Power
Supply Shield
JU2
x 18
8 7 6 5 4 3 2 1
RJ- 45
110 Connector
1
2
3
J5
J1
+
-
S
1
2
3
+
-
S
AES/L
R
J2 J3
JU3
15v-
15v+
Power
Supply
Ground
JU5
1/2 Amp
auto reset
fuse
R2 JU4
R1
1/2 Amp auto reset
fuse
J4
Hub Chassis Ground
JU1
JU91
Shield
Blu/Wht G
Wht/Org L+
Org/Wht L-
Wht/Grn R+
Grn/Wht R-
Wht/Brn - 15V
Brn/Wht + 15V
Slt/Wht Shd
Wht/Slt Shd
Wht/Blu n/c
Insert jumper JU91 to
connect the chassis
ground to the power
supply shield
Insert a jumper above
any right-hand RJ-45 to connect that channel to the power supply shield
Insert a jumper above any left-hand RJ-45 to
connect that channel to
the common Hub chassis
ground boss
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
4
Page 6
For Assy:
HUB32
Rev: 01/05
StudioHub+ Model HUB32
Engineered for Console Harnesses
Product Key
Name HUB32
Mount Rack (1 R.U.)
Channels 32
CAT-5 Pairs 2 (1,2,3,6)
Power Link no
Connectors Mini-amp & RJ-45
Versions Rack Mount
General
Each of the 32 Hub channels consists of two 2-pin mini-Amp input connectors in parallel with an RJ-45. Each channel carries a stereo balanced audio pair, or balanced digital audio signal. Custom length and configuration harness cables may be factory ordered to interconnect the Hub to various consoles, audio routers and engines or multi-channel Digital Audio Workstations.
There are two rear panel mini-Amp connectors which provide connectivity to pairs 1 & 2 of each front-panel RJ-45. Harness cables may be plugged up to program each channel for analog stereo, mono or AES-EBU operation.
Grounding Information
RJ-45 connector shields are isolated from each other and from the front panel metalwork.
AES/L
R
Pair 1 & 2 mini-amp 2-pin connectors for each channel. Plug in 2 cables for analog
stereo, 1 cable for analog mono, or AES/
EBU digital
A rear panel ground pin exists to allow the interconnection of a ground lead from the harness cable bundle.
J19
12+
-
Mini Amp
1
2+-
J18
RJ-45
8 7 6 5 4 3 2 1
J1
x 32
J17 J50
Shield
Mini Amp
4B
Ground connect
to chassis ground
Install Cable to Chassis Ground if Desired
18A19B19A
Front Panel
SHLD1B1A2B2A3B3A4A5B5A6B6A7B7A8B8A9B9A10B10A11B11A12B12A13B13 A14B14A15 B15 A16 B16ASHLD
SHLD17B17A18B20B20A21 B21A22B22A23B23A24B24A25B25A26B26A27B27A28B28A29B29A30B30A31B31A32B32ASHLD
Rear Panel
(internal)
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
5
Page 7
For Assy:
HUB36-DC
Rev: 01/05
StudioHub+ Model HUB36-DC
Engineered for Console Harnesses
Product Key
Name HUB36
Mount Hub (3 R.U)
Channels 36
CAT-5 Pairs 2 (pins - 1,2,3&6)
Power Link yes
Connectors Mini-amp & RJ-45
Versions Full Hub
General
Each of the 36 Hub channels consists of two 2-pin mini-Amp input connector in parallel with an RJ-45 connector. Each channel carries a stereo balanced audio pair, or balanced digital audio signal. Custom length and configuration harness cables may be factory ordered to interconnect the Hub to various consoles, audio routers and engines or multi-channel Digital Audio Workstations.
DC Power
If using any StudioHub+ "DClink" accessories, plug a StudioHub +/- 15 volt power supply into the power supply connector. Both Hub LED s will illuminate. Insert both power jumpers only on only the circuits that utilize a powered accessory (e.g. MatchJack, mic preamp, etc.).
Grounding Information
RJ-45 connector shields may be isolated from each other or optionally connected to each other or to the hub chassis by inserting jumper by each connector.
To use the hub as a common ground point, insert a jumper below each RJ-45 that you want common to be in common with the chassis ground. If you have a StudioHub+ 15V power supply connected to the hub, to connect each RJ-45 to the power supply shield, insert a jumper above each RJ-45. Insert JU-33 to common the chassis ground and power-supply shield.
Insert jumper above any
RJ-45 upper to connect
that channel s shield to
the common chassis
ground
Insert jumper below any
RJ-45 to connect that
channel s shield to the
common shield bus
Install both DC jumpers to activate StudioHub+
DC-Link connection to
provide +/-15V DC to
any powered accessory
Upper and lower 2-pin
mini-amp connectors
wire to source gear audio
I/O via certain harness
cables
Power Supply Ground
AES/L
R
J5
1
2
3
Mini Amp
1
2
3
J1
R3
1/2 Amp
auto reset
fuse
RJ- 45
+
-
S
+
-
S
J3
8
7 6
5
4
3
2
1
Shield
1/2 Amp
auto reset
R1
fuse
Hub Chassis
Ground
JU5
JU7
Radio Systems, Inc. (856) 467-8000
15v-
15v+
JU3
+/-15V external power
x 36
JU1
Power Supply
Shield
JU145
601 Heron Drive
supply main and loop-
thru jumpers
Logan Twp., New Jersey 08085
LED s indicate presence of
+/- 15V DC
6
Page 8
For Assys:
HUB12
Rev: 01/05
Engineered for StudioHub+ to Audio Science Audio Card Break-Out
Product Key
Name HUB12
Mount rack (1 r.u.)
Channels 8 Out / 4 In
CAT-5 Pairs 2 (all)
Power Link no
Connectors
1 MD-50 (for analog) / 1 MD-26 (for digital)
12 RJ-45 / 2 BNC (for sync.)
Versions Rack-mount only (as pictured)
INPUT 1 LEFT - 1 INPUT 1 RIGHT - 2 INPUT 2 LEFT - 3 INPUT 2 RIGHT - 4 INPUT 3 LEFT - 5 INPUT 3 RIGHT - 6 INPUT 4 LEFT - 7 INPUT 4 RIGHT - 8 OUTPUT 4 RIGHT - 9 OUTPUT 4 LEFT - 10 OUTPUT 3 RIGHT - 11 OUTPUT 3 LEFT - 12 OUTPUT 2 RIGHT - 13 OUTPUT 2 LEFT - 14 OUTPUT 1 RIGHT - 15 OUTPUT 1 LEFT - 16 OUTPUT 5 RIGHT - 17 OUTPUT 5 LEFT - 18 OUTPUT 6 RIGHT - 19 OUTPUT 6 LEFT - 20 OUTPUT 7 RIGHT - 21 OUTPUT 7 LEFT - 22 OUTPUT 8 RIGHT - 23 OUTPUT 8 LEFT - 24
GROUND 25
26 INPUT 1 LEFT + 27 INPUT 1 RIGHT + 28 INPUT 2 LEFT + 29 INPUT 2 RIGHT + 30 INPUT 3 LEFT + 31 INPUT 3 RIGHT + 32 INPUT 4 LEFT + 33 INPUT 4 RIGHT + 34 OUTPUT RIGHT + 35 OUTPUT LEFT + 36 OUTPUT RIGHT + 37 OUTPUT LEFT + 38 OUTPUT RIGHT + 39 OUTPUT LEFT + 40 OUTPUT RIGHT + 41 OUTPUT LEFT + 42 OUTPUT RIGHT + 43 OUTPUT LEFT + 44 OUTPUT RIGHT + 45 OUTPUT LEFT + 46 OUTPUT RIGHT + 47 OUTPUT LEFT + 48 OUTPUT RIGHT + 49 OUTPUT LEFT + 50 GROUND
Analog I/O
Connector (MD-50)
NOTE - These pin-outs typically correlate 1 to 1 for Audio
Science series 4000, 5000 and 6000 audio cards so that straight-
thru patch cables may be utilized.
StudioHub+ Model HUB12
General
INPUT 1 AES- 1 INPUT 2 AES- 2 INPUT 3 AES- 3 INPUT 4 AES- 4 OUTPUT 1 AES- 5 OUTPUT 2 AES- 6 OUTPUT 3 AES- 7 OUTPUT 4 AES- 8 OUTPUT 5 AES- 9 OUTPUT 6 AES- 10 Sync 11 Word Clock 12 GROUND 13
Digital I/O
Connector (MD-26)
14 INPUT 1 AES + 15 INPUT 2 AES + 16 INPUT 3 AES + 17 INPUT 4 AES + 18 OUTPUT 1 AES + 19 OUTPUT 2 AES + 20 OUTPUT 3 AES + 21 OUTPUT 4 AES + 22 OUTPUT 5 AES + 23 OUTPUT 6 AES + 24 Sync 25 Word Clock 26 GROUND
The Hub12 is specifically engineered to break­out up to 8 stereo output channels and 4 stereo input channels from series 4000, 5000 and 6000 Audio Science professional multi-channel audio cards. Inputs and outputs appear on RJ­45 connectors and conform to the StudioHub+ audio pin-out standard. Front panel high­density MD-50 & MD-26 connectors mate with similar connectors on the various ASI cards supported.,
BNC Synchronous connectors
Front panel BNC connectors provide Word­Clock sync inputs and outputs as supported by the individual ASI card models. Insert internal jumpers JU-9 & JU-10 to activate these connectors.
Grounding Information
Front panel RJ-45 shields are all normally isolated from each other, but may be connected together via a common ground bus by inserting internal jumpers JU-1 thru JU-12. This bus may be connected to the HUB12 chassis ground by inserting internal jumper JU-15.
Analog I/O
50 Pin
Miniature D
26 Pin
Miniature D
Digital I/O
World Clock In World Clock Out
RJ-45
8 7 6 5 4 3 2 1
Radio Systems, Inc. (856) 467-8000
Channel Color Pair RJ-45 Pin 110 Pin
L+ / AES + Wht/Org 1 3 L- / AES - Org/Wht 2 4
JU1
JU15
R+ Wht/Grn 3 5 R- Grn/Wht 6 6 nc Wht/Blu 5 1 GND Blu/Wht 4 2
Chassis Ground
Common
Ground
15V- Wht/Brn 7 7 15V+ Brn/Wht 8 8 Shield Wht/Slt Shield 9 Shield Slt/Wht Shield 10
601 Heron Drive
Logan Twp., New Jersey 08085
StudioHub+ Pin Outs
7
Page 9
Radio Systems, Inc. 601 Heron Drive Logan Twp., New Jersey 08085 (856) 467-8000 Fax (856) 467-3044 www.studiohub.com
8
Page 10
StudioHub+ GPI 12/24 Channel
Remote Control Hub
RJ-21 Interconnect Cables
Custom RJ-21 to DB connector cables are
available to interconnect every major GPI
controller to the GPI Hub
General
The GPI Hub-12/24 allows the use of pre­programmed RJ-45 to DB connector adapters, for plug and play remote control of many broadcast units.
DB to RJ-21 cables are provided to interconnect most popular GPI controllers to the Hub-12/24, where the user than crosscut the 110 connectors to program various remote control functionality.
Two models are available. Order the GPI Hub-12 for 12 channels of control, or the dual GPI Hub-24 for 24 channels of control.
DC Power & Grounding
A barrier strip connector is provided for DC power. Programming jumpers for each RJ-45 channel allow quick programming of ground and DC when required on the RJ-45 connection to the controlled unit.
GPI Hub-12 GPI Hub-24
Rev.05/06
Order model GPI Hub-12 for a
single circuit board unit with 1 RJ-21
and 12 RJ-45 connectors.
Order model GPI Hub-24 for a dual
circuit board unit which adds the
lower circuit board for 2 RJ-21 and
24 RJ-45 connectors.
Install this jumper at any channel to connect ground to Pin #5 of the RJ-45
Install this jumper at any channel to connect DC + voltage to Pin #8 of the RJ-45
JU1 JU2
JU3 JU4
JU5 JU6
JU7
JU9
JU10
JU11 JU12
JU13 JU14
JU15 JU16
JU17 JU18
JU19 JU20
JU21 JU22
JU23 JU24
JU8
JU1 JU2
JU3 JU4
JU5 JU6
JU7
JU9
JU10
JU11 JU12
JU13 JU14
JU15 JU16
JU17 JU18
JU19 JU20
JU22
JU23 JU24
JU8
Cross-cut between RJ-21 110 connectors and RJ-45 110 connectors to program RJ-21 to RJ-45 control line connectivity
JU21
RJ-45 Control Adapters
Custom RJ-45 to DB connector adapters
are available pre-programmed to connect
every major manufacturers DB remote
control connector to the GPI hub via
standard RJ-45 patch cables
Power & Ground Programming
Note: These connecters are in parallel
3 groups of + and ground connections are available. Each group feeds 3 sets of 4 RJ­45 connectors.
To send DC to pin 8 of the RJ-45's in group 1 (RJ-45's 1-4), apply DC to screw terminal +1 or 110 connector pin +1. Then install jumper JU2, JU4, JU5, JU6, or JU8 at each RJ-45 where DC needs to be present.
To send ground to pin 5 of the RJ-45's in group 1 (RJ-45's 1-4), apply ground to screw terminal -1 or 110 connector pin -1. Then, install jumper JU1, JU3, JU5, or JU7 at each RJ-45 where ground needs to be present.
Repeat (with appropriate screw terminal and jumper numbers) for RJ-45 group 2 (RJ-45's 5-8) and group 3 (RJ-45 9-12)
Note that if the same DC voltage or ground connection is needed between groups, the DC or ground lead can be connected in parallel at the lower screw terminals or the 110 connector.
Connect DC voltage and/or ground at this 110 block or screw terminal to apply ground or DC voltage to these RJ-45 jumpers. (See below for specific programming instructions).
+1 -1 +2 -2 +3 -3 S S
+1 -1 +2 -2 +3 -3
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
9
Page 11
For Assy: MINITIE12-4 MINITIE24-4
Rev: 01/05
StudioHub+ Model MINITIE12-4 & MINITIE24-4
Engineered for Inter-Studio Tie Lines
General Mini Tie Hubs provide multi-pair inter-studio connectivity by splaying out CAT-5 25 pair cable to individual RJ-45 connectors via a 50 pin RJ-21 mass connector. Mini Hubs are designed to mount and fit where the capacity of full-size hubs is not needed. Depending on the model selected, either 2 or 4 CAT-5 pairs are connected to each RJ-45 connector. Double the density is achieved if only 2 pairs (4 wires) are required to connect to each RJ-45. Generally, 2 pair is sufficient to support StudioHub analog and digital audio circuits. All 4 pairs (8 wires) are needed to support KVM and other special multi-wire equipment circuits.
Mounting Mini tie-line hubs are available in single units on small wall­mountable plates, or in double density on 1 r.u. rack mounts
Grounding Information. RJ-45 connector shields are common on the mini tie hubs.
Two jumpers are provided that allow the unused CAT-5 25
th
pair to be connected to this common shield, as well as to the hub chassis.
Each RJ-45 provides 4
wires of connectivity via the CAT-5 25-pair cable
Product Key
Name MINITIE12-4 / MINITIE24-4
Mount Wall Mount / Rack Mount (1 r.u.)
Channels 24 / 12
CAT-5 Pairs 2 (pins - 1,2,3,6)
Power Link no
Connectors RJ-21, RJ-45
Versions Plate, Rack
J2
RJ-21
Unused Pair (25)
Model -
MINITIE12-4
RJ- 45
J1
8 7 6 5 4 3 2 1
JU1
Shield
x 24 or 12
JU2
Hub Chassis Ground
RJ-21 connects 25-pair CAT-5 cable
carrying six 4-pair circuits. One 25-pair
CAT-5 cable is required for 12 circuit
model. Two 25-pair CAT-5 cables are
required for 24 circuit model.
Radio Systems, Inc. (856) 467-8000
Insert jumper to tie
power supply shield to
hub chassis ground
Each RJ-45 provides 4 wires of connectivity via the CAT-5 25-pair cable
601 Heron Drive
Logan Twp., New Jersey 08085
power supply shield to
Insert jumper to tie
hub chassis ground
Model - MINITIE24-4
bk
Page 12
For Assy:
MINITIE12-8
MINITIE6-8
Rev: 01/05
StudioHub+ Model MINITIE6-8 & MINITIE12-8
Engineered for Inter-Studio Tie Lines
General Mini Tie Hubs provide multi-pair inter-studio connectivity by splaying out CAT-5 25 pair cable to individual RJ-45 connectors via a 50 pin RJ-21 mass connector. Mini Hubs are designed to mount and fit where the capacity of full-size hubs is not needed. Depending on the model selected, either 2 or 4 CAT-5 pairs are connected to each RJ-45 connector. Double the density is achieved if only 2 pairs (4 wires) are required to connect to each RJ-45. Generally, 2 pair is sufficient to support StudioHub analog and digital audio circuits. All 4 pairs (8 wires) are needed to support KVM and other special multi-wire equipment circuits.
Mounting Mini tie-line hubs are available in single units on small wall­mountable plates, or in double density on 1 r.u. rack mounts
Grounding Information. RJ-45 connector shields are common on the mini tie hubs.
Two jumpers are provided that allow the unused CAT-5 25
th
pair to be connected to this common shield, as well as to the hub chassis.
Each RJ-45 provides 8 wires of connectivity via the CAT-5 25-pair cable
Product Key
Name MINITIE6-8 / MINITIE12-8
Mount Wall Mount / Rack Mount (1 r.u.)
Channels 6/12
CAT-5 Pairs 8 (all)
Power Link no
Connectors RJ-21, RJ-45
Versions Plate, Rack
J4
RJ-21
Unused
Pair
Shield
J1
RJ- 45
JU2
x 12 or 6
Hub Chassis Ground
JU1
8 7 6 5 4 3 2 1
RJ-21 connects 25-pair CAT-5 cable
carrying six 4-pair circuits. One 25-pair
CAT-5 cable is required for 6 circuit
model. Two 25-pair CAT-5 cables are
required for 12 circuit model.
Insert jumper to tie
power supply shield to
hub chassis ground
Each RJ-45 provides 8 wires of connectivity via the CAT-5 25-pair cable
Model - MINITIE6-8
Insert jumper to tie
power supply shield to
hub chassis ground
Model - MINITIE12-8
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
bl
Page 13
For Assy: TIE24-4DC TIE12-4DC
Rev: 01/05
StudioHub+ Model Tie-24-4DC & Model Tie-12-4DC
Engineered for Inter-Studio Tie Lines
General
Tie Hubs provide multi-pair inter-studio connectivity by splaying out CAT-5 25 pair cable to individual RJ-45 connectors via a 50 pin RJ-21 mass connector. Depending on the model selected, either 2 or 4 CAT-5 pairs are connected to each RJ-45 connector. Double the density is achieved if only 2 pairs (4 wires) are required to connect to each RJ-45. Generally, 2 pair is sufficient to support StudioHub analog and digital audio circuits. All 4 pairs (8 wires) are needed to support KVM and other special multi-wire equipment circuits.
DC Power
DC Tie-Line hub models allow StudioHub+ DC-Link +/­15 volt power to be added on the far-side of the link to power local StudioHub+ powered peripherals (such as headphone amps and MatchJacks). An external StudioHub+ DC power supply must be utilized. Jumpers and re-settable fuses for each RJ-45 channel allow the DC power to be added. The power option is only available on 2-pair per RJ-45 Hub models.
Grounding Information
RJ-45 connector shields may be optionally connected to the chassis ground by inserting a jumper. A jumper is also provided to allow the unused CAT-5 25
th
pair to be connected to this common shield bus. In addition, on powered models, the power supply shield may be jumper connected to the RJ-45 shields.
Name TIE24-4Powered
Mount Full Hub/Half Hub
Channels 24/12
CAT-5 Pairs 2 (pins - 1,2,3,6)
Power Link yes
Connectors RJ-21/ 2 RJ-45
Versions Full Hub/Half Hub/Board Only
Product Key
Two RJ-45 s in parallel to
bridge inputs and outputs
Note: All 3 of these
jumpers must be inserted
for any channel that is
powering a remote
DC-Link device (e.g.
StudioHub+ Matchjack
or Pre-Amp)
Install both DC jumpers to activate StudioHub+
DC-Link connection to
provide +/-15V DC to
any powered accessory
Insert jumper to tie
power supply shield to
hub chassis ground
8
7 6 5 4
3 2 1
Shield
RJ- 45
Hub
Chassis
Ground
JU38
8
7 6 5 4
3 2 1
RJ-45
J2 J3
JU3
15v-
15v+
Power
Supply
Ground
JU28
Unused
Pair (25)
JU1
R1 JU2
1/2 Amp auto-reset
fuse
1/2 Amp
auto-reset
fuse
R2
JU39 JU40
Power Supply
Shield
x 24 or 12
RJ-21
Shield
J4
Model TIE24-4DC shown
also available as hub 12 channel - model TIE12-4DC
RJ-21 connects 25-pair
CAT-5 cable carrying six
4-pair circuits
Insert jumper to tie
power supply shield to
hub chassis ground
LED s indicate presence
of +/- 15V DC
+/-15V external power
supply main and loop-
thru jumpers
Insert jumper to
connect the common
shield bus to power
supply ground
This jumper connects the
channel to the common
power ground bus when
installed. Required for
DC-Link operation.
Note: This jumper must
be removed for KVM
extender links and other
data devices that use
CAT-5 wire #4 (blu/wht)
Insert jumper to connect
the common shield bus
to chassis ground
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
bm
Page 14
For Assy:
TIE24-8,
TIE12-8
Rev: 01/05
StudioHub+ Model TIE24-8 & Model TIE12-8
Engineered for Inter-Studio Tie Lines
General
Tie Hubs provide multi-pair inter-studio connectivity by splaying out CAT-5 25 pair cable to individual RJ-45 connectors via a 50 pin RJ-21 mass connector. Depending on the model selected, either 2 or 4 CAT-5 pairs are connected to each RJ-45 connector. Double the density is achieved if only 2 pairs (4 wires) are required to connect to each RJ-45. Generally, 2 pair is sufficient to support StudioHub analog and digital audio circuits. All 4 pairs (8 wires) are needed to support KVM and other special multi-wire equipment circuits.
DC Power
DC Tie-Line hub models allow StudioHub+ DC-Link +/­15 volt power to be added on the far-side of the link to power local StudioHub powered peripherals (such as headphone amps and MatchJacks). An external StudioHub+ DC power supply must be utilized. Jumpers and re-settable fuses for each RJ-45 channel allow the DC power to be added. The power option is only available on 2-pair per RJ-45 Hub models.
Grounding Information
RJ-45 connector shields may be optionally connected to the chassis ground by inserting a jumper. A jumper is also provided to allow the unused CAT-5 25
th
pair to be connected to this common shield bus. In addition, on powered models, the power supply shield may be jumper connected to the RJ-45 shields.
Name TIE24-8 / TIE12-8
Mount Full Hub / Half Hub
Channels 12 / 12
CAT-5 Pairs 4 (all)
Power Link no
Connectors RJ-21, 2 RJ-45 & 110
Versions Full Hub/Half Hub/Board Only
Product Key
Model TIE24-8 pictured
also available as hub 12 channel - model TIE12-8
2 RJ-45 in parallel to
bridge inputs or outputs
10 pin 110-style
connector provides
access to all 4 CAT-5
pairs and cable shield
RJ-21 connects 25-pair
CAT-5 cable carrying six
4-pair circuits. Four 25-
pair RJ-21 cables
required to connect all
24 4-pair Hub circuits.
Insert jumper to connect
the RJ-45 shields to
chassis ground
8 7 6 5 4 3 2 1
Shield
RJ- 45
Hub Chassis Ground
JU2
x 12 or 6
8 7 6 5 4 3 2 1
RJ- 45
110 Connector
J6
J3-1
JU1
J4-1
Unused
Pair (25)
J1
Shield
RJ-21
Blu/Wht G
Wht/Org L+
Org/Wht L-
Wht/Grn R+
Grn/Wht R-
Wht/Brn - 15V
Brn/Wht + 15V
Slt/Wht Shd
Wht/Slt Shd
Wht/Blu n/c
Connects 25th CAT-5 pair
to shields of the RJ-45 s
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
bn
Page 15
For Assy:
PATCH-44
Rev: 01/05
StudioHub+ Model PATCH-44
with Front Panel Normalizing Switching
1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
23724 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
Front Panel normalizing switch connects upper jack left &
right audio inputs to lower jack left & right audio outputs
when switch is in up position. Audio remains present
(monitorable) on both input & output jacks regardless of
normalizing switch position or the insertion of patch cords.
Each RJ-45 jack provides a stereo balanced audio circuit. Jacks are
shielded, with a ground connection that may be floated or commoned via
a rear panel jumper to chassis ground.
Audio connection to each front
panel jack is provided on the rear panel via a parallel RJ-45 connector
or 110 punch style connection (see
chart below)
wht
/
blu
blu
/
wht
wht
/
org
org
/
wht
wht
/
grn
wht
/
blu
blu
/
wht
wht
/
org
org
/
wht
wht
/
grn
1 2 3 4 5 6 7 8 9 10
Left
Audio
Right Audio
Left
Audio
Right
Audio
+ - + - G + - + - G
RJ-45 #1 RJ-45 #2
General
The StudioHub+ 44 position patch panel provides 22 stereo analog or digital outputs and inputs on a 3 r.u. rack panel via RJ-45 connectors. Standard RJ-45 shielded or non-shielded straight-thru patch cords of 18 or longer may be used to make patch connections.
Normalling
Front panel accessible normalling dip-switches establish a quarter normalled full-time connection between the upper and lower output and input connectors so that signal in made without the use of a patch-cord. Note that when the normalling function switch is on (up,) signal flow is not interrupted by inserting a RJ-45 patch cord in either the upper or lower circuit connector.
Rear Panel Connectivity
44 Rear panel RJ-45 s are provided in parallel with the front panel connectors for plug-and-play wiring ease to the panel. In addition, rear panel 110-style punch blocks are in-line for every circuit to allow cabling access to every signal. Note that the panel passes 2 pairs (pins 1, 2, 3, &6) of the CAT-5 cable, leaving pairs 3&4 unconnected. This makes the panel compatible for StudioHub+ analog and digital audio connectivity as well as certain Ethernet applications, but not CAT-5 circuits requiring other then pairs 1 & 2.
Grounding Information.
RJ-45 connector shields are isolated from each other but may be optionally connected in common by inserting a jumper on the rear of the panel by each connector. A jumper is also provided to connect the RJ-45 shield bus to the patch panel chassis ground.
Rear-Panel Connectivity
on RJ-45 and 110 punch-blocks
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
bo
Page 16
STEREO ANALOG MODEL (1/3
rd
WIDTH REAR PANEL ADAPTER)
4 RJ-45 connectors each conducting 4-pair (all RJ-45 pins) to 2-pairs each
(RJ-45 pins 1,2,3 & 6) of two front panel RJ-45's.
SHIELDSHIELDSHIELDSHIELD
JU4 JU3 JU2 JU1
SHIELDSHIELDSHIELDSHIELD
JU8 JU7 JU6 JU5
STUDIOHUB+ PATCH 48 STEREO ANALOG BOARD
For Assy:
PATCH48
Rev: 09/06
StudioHub+ Model PATCH - 48 - 2 Rack Units High
with 1/3 Width Rear Adapters
24 Channels of RJ-45 Thru-Put with Front Panel Normalizing Switching
and Rear-Panel Interchangeable Connector Adapters (See Rear for Adapter Pin-Outs)
®
Rear Adapters 6 Required (3 per row)
Install on top row and bottom row of rear panel (in any mix)
I/O MODEL (1/3rd WIDTH REAR PANEL ADAPTER)
8 RJ-45 connectors each conducting 2-pair (RJ-45 pins
1,2,3 & 6) on a 1-to-1 basis from the front panel RJ-45's to
the corresponding rear panel RJ-45.
SHIELDSHIELDSHIELDSHIELD
JU4 JU3 JU2 JU1
SHIELDSHIELDSHIELDSHIELD
JU8 JU7 JU6 JU5
STUDIOHUB+ PATCH 48 I/O BOARD
AES/EBU MODEL (1/3rd WIDTH REAR PANEL ADAPTER)
2 RJ-45 connectors each conducting 4-pair (all RJ-45 pins)
to 1-pair each (RJ-45 pins 1 & 2) of four front panel RJ-45's.
JU8
EDAC MODEL (1/3rd WIDTH REAR PANEL ADAPTER)
16 EDAC #556003520102 male 3-pin connectors (with wings
removed), each conducting 1 balanced audio signal to 1
channel of 1 front panel RJ-45.
SHIELDSHIELDSHIELDSHIELD
JU4 JU3 JU2 JU1
SHIELDSHIELDSHIELDSHIELD
JU7 JU6 JU5
STUDIOHUB+ PATCH 48 AES/EBU BOARD
J15 RIGHT J14 RIGHT J13 RIGHT J12 RIGHT J11 RIGHT J10 RIGHT J9 RIGHTJ16 RIGHT
J7 LEFT J6 LEFT J5 LEFT J4 LEFT J3 LEFT J2 LEFT J1 LEFT
J8 LEFT
JU8
JU4 JU3 JU2 JU1JU7 JU6 JU5
2-pin jumper pins connect RJ-45
shield to corresponding front panel
RJ-45 shield. All RJ-45 shields
remain isolated from each other
(not in common)
Front Panel normalizing switch connects upper jack left & right audio inputs to lower
jack left & right audio outputs when switch is in up position. Audio remains present
(monitorable) on both input & output jacks regardless of normalizing switch position
or the insertion of patch cords.
Each RJ-45 jack provides a stereo balanced audio or AES/
EBU digital circuit. Jacks are shielded, with a ground
connection that may be floated or commoned via a rear
panel jumper to chassis ground.
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
bp
Page 17
For Assy:
12072
Rev: 10/04
For Assys:
Sum8 Sum4
Rev: 01/05
StudioHub+ Model SUM8 & Model SUM4
4x2 Stereo Audio Mixer Amplifier
In 1a
In 1b
In 2a
In 2b
In 3a
In 3b
In 4a
In 4b
In 1 - RIGHT
In 1 - LEFT
In 2 - RIGHT
In 2 - LEFT
In 3 - RIGHT
In 3 - LEFT
In 4 - RIGHT
In 4 - LEFT
Out 1
Out 2
+/- 15V DC Power
connector for pass-
thru power on dual
Hub, dual DA or dual
Mixer panels
Insert jumper in header to
connect RJ-45 shield to Hub
electrical ground
Note - the same applies to
jumpers for inputs 2, 3, & 4
above
Insert jumpers in both
headers to mono inputs
Note - the same applies to jumpers for inputs 2, 3, & 4 above
LED s indicate presence
of +/- 15V DC
Insert jumpers in header
to connect hub electrical ground to chassis ground
Insert jumper in
header to connect
output RJ-45
connector shield to
Hub electrical ground
Install jumper in upper
header to add input to
output #1. Install jumper in lower
header to add input to
output #2.
Note - the same
applies to jumpers for
inputs 3, 2, 1 above.
Jumper right and center
pins (on both headers)
to increase input level
sensitivity by +10dB.
Jumper left and center pins (on both headers)
to increase input level
sensitivity by +20dB
Note - the same
applies to jumpers for
inputs 3, 2, & 1 above.
All stereo A & B inputs
are in parallel
( loop-thru )
Add a second section
of Sum4 here to
create a Sum8
8 input summing
amp (or add any
StudioHub+ board
to create a combo
product.)
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
bq
Page 18
For Assy:
12072
Rev: 10/04
For Assys: DA12-DC
DA6-DC
Rev: 01/05
StudioHub+ Model DA12-DC & Model DA6-DC
Single and Dual Stereo Distribution Amplifier
Left Right
Out 1 - RIGHT Out 4 - LEFT
Out 1 - LEFT Out 4 - RIGHT
Out 2 - RIGHT Out 5 - LEFT
Out 2 - LEFT Out 5 - RIGHT
Out 3 - RIGHT Out 6 - LEFT
Out 3 - LEFT
Out 6 - RIGHT
Out 1
Out 2
Out 3
In 1a
In 1b
Out 4
Out 5
Out 6
+/- 15V DC Power
connector for pass­thru power on dual
Hub, deal DA or dual
Mixer panels
Insert jumpers in
both headers to
enable +/- DC on
output cable to
power StudioHub
DC-Link devices
Note - DC not
available on outputs
2 & 5
Insert jumper under
output headers to
connect RJ-45
shielded to Hub
electrical ground
Green LED s indicate
audio presence at
+24 dB
+/- 15V DC Power connector for pass-
thru power on dual
Hub, dual DA or dual
Mixer panels
LED s indicate presence
of +/- 15V DC
Insert jumpers in
both headers to
mono input
Insert jumper under
output headers to
connect RJ-45
shielded to Hub
electrical ground
Jumper right and
center pins (on both headers) to increase
input level sensitivity
by +10 dB. Jumper
left and center pins
(on both headers) to
increase level
sensitivity by +20 db
Parallel stereo audio
inputs are provided
for program loop
through
Insert jumper in
header to connect
Hub electrical to
chassis ground
Insert jumper in
header to connect
input connector
RJ-45 shields to Hub
electrical ground
Insert jumpers in
both headers to
enable +/- DC on
output cable to
power StudioHub
DC-LINK devices
Note - DC not
available on outputs
2 & 5
Add a second section
of DA6-DC here to
create a DA12-DC
12 output DA (or add
any StudioHub+ board to create a
combo product.)
Radio Systems, Inc. (856) 467-8000
601 Heron Drive
Logan Twp., New Jersey 08085
br
Page 19
For Assy.
Part # 14691
rev. 01/07
601 Heron Drive
(856) 467-8000
Radio Systems, Inc.
Logan Twp., New Jersey 08085
Fax (856) 467-3044
www.studiohub.com