To: SIEMIC
From: Ken Simonelic
RE: User Manual XS24200
OEM Installation Guide
Installation Notes
• Multi-surface pads provide both bottom pads for high volume reflow soldering and edge pads for low
volume hand soldering.
• Power supply to module should have less than 10mVrms noise between 0-10MHz, and spikes should be
minimal.
sales@radiodatacom.com
• Regulator should have a fast response time < 20µs. It is essential that the power rail recover quickly.
• 10µF or larger capacitor filter for VDD input.
• All unused pins should be unconnected.
• A surface mount antenna should be placed very near the module RF output pin using a 50 ohm
transmission line, and should be designed according to antenna manufacturer specifications.
• The area around the module should be free of any ground planes, power planes, trace routings, or
metal. Minimum clearance is 5mm, but additional clearance allows improved range and throughput.
• Recommend connections for all four UART pins (DB-9 connector or test points) for firmware updates.
• Recommend test points for all four SPI pins, for emergency factory debugging and firmware reloading.
• Do not clean modules with Alcohol which can interact with no-clean solder flux residue.
• Do not use ultra sonic cleaning, which may cause internal interconnect damage.
• Do not modify any hardware components on the module without prior written consent.
• Do not modify any firmware without prior written consent.
• Final products that contain a Radio Datacom Bluetooth Module device must display a visible label
referring to the enclosed module similar to the following label:
Notice of FCC Regulatory Compliance
This module has been tested and found to comply with the FCC Part 15 Rules. These limits are designed to
provide reasonable protection against harmful interference in approved installations. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
Phone (602) 235-0350 www.RadioDatacom.com
sales@radiodatacom.com
• This device may not cause harmful interference, and
• This device must accept any interference received, including interference that may cause undesired
operation.
Modifications or changes to this equipment not expressly approved by Radio Datacom may void the user’s
authority to operate this equipment.
RF Exposure Warning
The device has been evaluated to general population RF exposure limit environment. It is safe to use to closer
(less than 20cm) proximity to human body.
Phone (602) 235-0350 www.RadioDatacom.com