Radiant RMAS 24 E, RMAS 21 E User Manual

CE
0694
ENGLISH
Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY By Technical Department
USER MANUAL
Model
RMAS 24 E
TYPE C ROOM SEALED
User Manual
Wall hung storage boiler – Cod. 99948NA – November 2002
I
BOILER OPERATION AND ADJUSTMENT PROCEDURES FOR USER
Before turning on the boiler read the following warnings carefully .
Make sure that the warranty booklet carries the stamp of the CORGI registered technician (you can check this by contacting corgi on 01256.372200) responsible for installing the boiler. Installation, starting up for the first time, adjustments and maintenance operations must all be carried out solely by qualified technicians. Incorrect installation may cause damage to persons, animals or property for which the manufacturer cannot be held liable.
WARNING!
Do not start the boiler unless you are sure it has been thoroughly tested by an authorised technician. Check that the regulations regarding air intakes and ventilation of the room where the boiler is installed have been
fully complied with.
The anti-freeze system will come into operation only if the boiler is in the winter () or summer () position (with
selector switch 1 in fig. 1 turned to the summer or winter position) and the gas supply turned on. The manufacturer can accept no responsibility for damage to the boiler caused by lack of observation of these requirements.
If the boiler should freeze up, under no circumstances attempt to turn it on but call the RADIANT HELP LINE –
(1329.828555) immediately.
LEGEND (see fig. 1)
1. SUMMER-WINTER ON-OFF SWITCH
2. LOCK-OUT INDICATOR
3. HEATING TEMPERATURE ADJUSTMENT
KNOB
4. WATER TEMPERATURE ADJUSTMENT KNOB
5. SPACE FOR ADDING AN OPTIONAL TIMER
SELF- DIAGNOSTIC LEGEND (see fig. 2)
6. OPERATING/ POWER INDICATOR
7. DOMESTIC HOT WATER OPERATION
8. HEATING OPERATION
9. FLASHING LIGHT DENOTING AIR
PRESSURE SWITCH FAILURE
10. FLASHING LIGHT DENOTING DOMESTIC WATER SENSOR FAILURE
11. FLASHING LIGHT DENOTING HEATING SENSOR FAILURE
12. FLASHING LIGHT DENOTING 90° C MAX TEMPERATURE SENSOR FAILURE
13. FLASHING LIGHT DENOTING LACK OF WATER IN SYSTEM
14. WATER PRESSURE LEVEL 1 BAR
15. WATER PRESSURE LEVEL 1.5 BAR
16. ELECTRONIC TEMPERATURE INDICATOR
Turning on procedure for electronic ignition (only for U.k. and Ireland):
turn on the gas cock situated under the boiler grill; turn selector switch 1 to the  symbol denoting winter (see fig.2); make sure that 6 light is ON (see fig. 2 pag. I) and the no.14 or no.15 lights are ON (see fig. 2); if light no.13 flashes, it
means water deficiency in the system: open the tap on the filling loop and fill the system until a pressure of 1.5 bar has been
reached (light no.15 ON; see fig. 2) and then close the tap. The automatic ignition system will turn the burner on. It may be necessary to repeat the procedure a few times to purge air from the pipes. To repeat the ignition procedure press release button 2 (see fig. 1) and then try the ignition procedure once again. If the boiler does not start, press the reset button (see fig. 1 pag. I). IMPORTANT
should the boiler fail to ignite wait 3 minutes before pressing button again.
If locking-out persists, turn boiler OFF and call RADIANT HELP LINE - 01329.828555.
6789
30
1 2
SELF DIAGNOSTIC
ELECTRONIC WATER
PRESSURE GAUGE
10 11 12 13
5040
16
60 70 80
3
4
14 15
1.51
5
Fig. 1
Fig. 2