User Manual
for model
RHA 28/100
Condensing boiler
with storage cylinder
USER INSTRUCTIONS
TA05A100.A0306
2
BOILER OPERATING INSTRUCTIONS.
Make sure that the authorised technician who tested the boiler has stamped the guarantee booklet.
The installation, first start-up, regulation and maintenance operations must be carried out exclusively by qualified personnel (e.g. Radiant authorised Service Centres). Incorrect installation can cause damage to property and injury to persons or animals, for which the manufacturer will not be held responsible.
During the installation, the technician must carry out the following checks:
The data on the rating plate must correspond to that of the mains supply networks (gas, electricity, water).
The boiler must be regulated according to its designed use and performance.
The flue gas exhaust and combustion air intake system must be correctly installed and operational.
The exhaust gas discharge and ventilation systems must comply with the requirements of national and local
standards regardless of whether the boiler is installed indoors, outdoors or in its own cabinet (see section “Reference standards”.
General warnings
Â
If there is any doubt as to whether the appliance has been tested by an authorised technician, do not attempt to start it. All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL, registered in accordance with current legislation and according to UNI-CIG 7129/01 and subsequent updates.
Â
Make sure that the requirements relating to the air intake and ventilation of the room in which the boiler is to be installed have been complied with.
Â
The boilers can be installed outdoors in a partially protected location, in accordance with current standards and where the minimum external temperature does not fall below –10°C. The manufacturer will not be held responsible for installation in locations where the temperature falls to below –10°C.
Â
The boiler is fitted with an antifreeze system. If the boiler is installed in a location where there is a risk of freezing, the anti-freeze system will only come into operation if the appliance is switched on (i.e. with the boiler switch in the ON position) and the gas supply valve is open. The manufacturer will not be held responsible for damage to the boiler caused by non-compliance with this instruction.
Â
Should any part of the boiler freeze-up, do not attempt to light it under any circumstances, but instead call the Service Centre immediately.
Â
The Benchmark Book is an integral part of an installation. The Benchmark handbook should be filled-in each time a boiler is installed. In addition to checking the combustion, all ordinary and extraordinary maintenance operations must be reported in the booklet together with the name of the person carrying out the maintenance and, where applicable, his company.
Â
The appliance’s combustion system must be checked every two years. This check includes testing the efficiency of the boiler and must be carried out by authorised personnel possessing the qualifications as required by current law.
Â
Do not obstruct the ventilation openings in rooms where there are gas-burning appliances installed (boiler, cooker, etc.).