Radiant EASYREMOTE Instruction Manual

Page 1
EASYREMOTE - RAD - ING - MAN.INST - 1010B - 40-00017
Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH
remote control device
EASYREMOTE
Page 2
Page 3
GENERAL INFORMATION
Technical features
Supply by communication bus Number of temperature levels 2 (DAY / NIGHT) Temperature setting range DAY 5 ÷ 30 °C Temperature setting range NIGHT 5 ÷ 30 °C Temperature setting range MANUAL 5 ÷ 30 °C Differential operation temperature OFF 0.0 ÷ 1.0 °C Differential operation temperature ON -1.0 ÷ -0.1 °C Correct working range room temperature probe -40 ÷ 50 °C Temperature resolution 0.1 °C Room anti-frost start temperature range 0.1 ÷ 10.0 °C Room anti-frost end temperature start value + 0.6 °C Timer programmer resolution 30 minutes Maximum number of startings and shutdowns per day 48 Number of standard heating programs 1 Number of standard storage tank programs 1 Internal clock time retention in case of power loss 1 ora Operating temperature range 0 ÷ 50 °C Stocking ambient temperature -10 ÷ 50 °C Size (L×H×D) 118×85×30 mm Maximum cable length for boiler connection 50 mt Cable section for boiler connection 0,5 ÷ 1,5 mm2
Page 4
GENERAL INFORMATION
Dear customer,
Our compliments for buying the remote control device EASYREMOTE, a product of latest technologies which will give you superior comfort.
In order to get top performance and to learn how to best use features and functions of this remote control device, carefully read this manual and keep it always readily accessible in case you need to refer to it.
CAUTION
Before connecting refer to the Instruction booklet to make
sure that the boiler was designed to be used with the
remote control device EASYREMOTE
Page 5
GENERAL INFORMATION
A Select operation status
B Set time and temperature
C Weekly program
D Change displayed value (turn) Select automatic / manual (press)
E Alarm reset
F Select temperature level (day/night)
G Temperature display
Page 6
GENERAL INFORMATION
LCD symbols
ICON STEADY BLINKING
Current temperature Fault code
Time/temperature
Current day of the week Change day of the week
Domestic hot water enabled
Domestic hot water requested
Heating enabled Heating requested
Manual mode
Burner on
Heating program Change heating program
Storage tank program Change storage tank
program
Current room set point Temporary change room
set point
Outside temperature
System pressure
Set time and day of
the week
Set day temperature
Set night temperature
Heating temperature Set heating temperature
Domestic hot water temperature
Set domestic hot water temperature
kd value
Current temperature level = day Current temperature level = night Fault, no more attempts left for restoring
Fault - restore attempts
available Fault requiring technical service Night level
Day level
Page 7
CONTENTS
1. How to use this instruction booklet ………...…………….………………..…1
2. General instructions.………………………………………………………...…..2
3. Main features…………………………………………………………..………...3
4. Installation….……………………………………………………………..……...4
5. Configurating operating parameters………..………………………………….8
6. Disabling thermo-regulation…………………………………………………..12
7. Boiler configuration (TSP)…… ………………………………………….…...13
8. Selecting operating mode……………….…………………………………….14
9. Setting up clock and temperature…..………………………………………..17
9.1. Setting up clock…………………………………………………………18
9.2. Setting up room DAY temperature……………………………….......20
9.3. Setting up room NIGHT temperature…………………………….......21
9.4. Setting up HEATING temperature…………………………………….22
9.5. Setting up DOMESTIC HOT WATER temperature ………………...23
9.6. Setting up outside probe KD value…………………………….……..24
10. Setting up clock and temperatures…………………………………………..26
10.1. MANUAL operation……………………………………………………..27
10.2. AUTOMATIC operation…………………………………………...……28
11. Weekly heating program………………………………………………..…….29
11.1. Display heating program………………………………………….……30
11.2. Change heating program………………………………………...…….31
12. Weekly storage tank program……………………………………………..…32
12.1. Display storage tank program…………………………………….......33
12.2. Change storage tank program……………………………………......34
13. Temporary change room temperature set point……………………………35
14. Fault signalling…………………………………………………………………36
14.1. Restorable faults………………………………………………………..36
14.2. Not restorable faults ……………………………………………….......37
15. Display values………………………………………………………………....38
15.1. Display set room temperature…………………………………….......39
15.2. Display temperature domestic hot water probe……………….…….39
15.3. Display temperature delivery probe ………………………………….40
15.4. Display temperature outside probe…………………………….……..40
16. Reset of default values …………………………………………………........41
17. Complete resetting………………………………………………………….…43
18. Room anti-freeze function…………………………………………………….44
Page 8
INSTALLER INSTRUCTIONS
1
1. How to use this instruction booklet
This booklet is divided into two sections, each of which having its own addressee:
Installer section, this gives instructions regarding the accurate
installation and configuration of the remote control device.
User section, this gives detailed instructions regarding the steps to
carry out in order to personalize the functioning of the EASYREMOTE remote control device.
Some hints
When a numeric value is blinking you can change it by turning button
.
The value as changed by turning button will be automatically stored when the blinking stops.
The use of the symbol shows the impossibility to dispose this product as domestic waste.
The correct disposal of this product helps to prevent potential negative consequences for the environment and human health.
Page 9
INSTALLER INSTRUCTIONS
2
2. General instructions
Carefully read this manual because it will give you important instructions regarding the safety of use, installation and maintenance.
The system must be implemented in compliance with the safety regulations in force.
After unpacking and before installing check that the product is intact.
This device is to be used only for the use it has been designed for: any different use is improper.
In case of repair contact only technical service centers authorized by the manufacturer.
Non-compliance with the above may endanger the safety of the device.
If the device is installed to control a low temperature zone, this zone must be equipped with a low temperature safety thermostat surveying it.
The manufacturer cannot be held liable for any damages resulting from bad operation, extraordinary events, configuration errors or improper, wrong and unreasonable use of the device.
The manufacturer reserves the right to eventually make changes to the device and whatever else appears necessary for the continual improvement thereof.
Page 10
INSTALLER INSTRUCTIONS
3
3. Main features
The EASYREMOTE remote control device has been designed to guarantee ideal temperature conditions at any moment of the day offering the possibility to set the boiler from remote.
The programming of the EASYREMOTE remote control device is extremely easy a large LCD-display makes it possible to check and change the set values at any time.
The EASYREMOTE remote control device is electrically connected to the boiler by means of two nonpolarized conductors. They give it the necessary supply to operate and constitute also the communication between the two devices. After installing it is immediately ready to run with its memorized standard program. This program can be changed according to the needs of the user.
Page 11
INSTALLER INSTRUCTIONS
4
4. Installation
The EASYREMOTE remote control device must be installed only by expert personnel. To correctly install the device and in compliance with the regulations in force about electrical appliances, use a dedicated line to connect it. In case this is impossible, any interference due to electric wires may cause poor working of the remote control device.
Install the EASYREMOTE remote control device at approx. 1.5 m over floor in a place suitable for correct sensing of the room temperature. Do not install behind doors, curtains, near heat sources nor expose to direct sunlight or water sprinkles.
Page 12
INSTALLER INSTRUCTIONS
5
1. Cut off electricity from boiler.
2. Use a screwdriver and gently press on the two lower splines to take off the device from the back of its fixing template.
3. Insert both ends of the connecting wire into their proper seat on the fixing template. Use the proper holes to install the EASYREMOTE remote control device directly onto the wall or onto a housing. The necessary screws are supplied together with the device.
Pay attention to the sign “ UP”.
Page 13
INSTALLER INSTRUCTIONS
6
4. Connect electricity to the terminal box.
N.B.: The connection is not polarized.
5. Fix your remote control device to its template. First insert the upper part and then press and turn until its completely closed.
6. Check in the boiler if there is a request to eliminate the jumper on the room thermostat terminals (if installed).
Page 14
INSTALLER INSTRUCTIONS
7
7. Supply power to the boiler.
Now the installation is completed. If it was done correctly the remote control device is now powered and the LCD display will show the following message for a few seconds:
As soon as the connection is established the normal operating condition will be displayed:
Page 15
INSTALLER INSTRUCTIONS
8
5. Configurating operating parameters
This operation must be done by technical service personnel only.
Errors in the configuation of your EASYREMOTE remote control device may lead to malfunctioning.
This operation configures the remote control device to be compatible with the boiler and the system to which it is connected.
1. Move the remote control device to OFF position.
2. Press the keys and and keep them pressed until the display will show PAr.
3. To confirm the function press button .
Instead of the time the display will show the parameter number, and instead of the temperature the parameter value. The parameter number will be blinking.
Page 16
INSTALLER INSTRUCTIONS
9
4.Turn button to select the parameter number to be displayed. The temperature display will show the corresponding parameter value.
5. Press button : to change this value. The corresponding parameter value will start blinking.
6. Turn button to change the displayed value.
7. If within 30 sec. no key is pressed, normal operation will be restored and the last change made will not be saved.
8. Press button to store the value.
9. To change the parameter repeat from point 4.
10. To exit the configuration context press key .
Page 17
INSTALLER INSTRUCTIONS
10
Hereafter you can find the definition of parameters you can change:
P00 - Room temperature sensor compensation
It is the value (-5.0°C ÷ +5.0°C) to be added to/detracted from the displayed room temperature in order to compensate any possible error.
P01 - Room anti-frost Start temperature Range
It defines the start temperature for the room anti frost function (0.1°C ÷ 10°C).
N.B.: 0.0 = value 0.0 disables the room anti frost function.
P02 - Differential operation temperature OFF
It is the value to be added to the room setpoint in order to define the end of the Central Heating Demand.
Example:
Tset point = 20.0 °C
P02 = 0.5 °C
Tset point + P02 = 20.0 + 0.5 = 20.5 °C
The central heating demand ends whenever the room temperature is higher then 20.5°C.
P03 - Differential operation temperature ON
It is the value to be subtracted from the room setpoint in order to define the start of the Central Heating Demand.
Example:
Tset point = 20.0 °C
P03 = 0.5 °C
Page 18
INSTALLER INSTRUCTIONS
11
Tset point - P03 = 20.0 - 0.5 = 19.5 °C
The central heating demand starts whenever the room temperature is lower then 19.5°C.
P04 - Thermo-regulation type
0 = ON/OFF
1 = Modulating on Room Temperature sensor
2 = Modulating on External Temperature Sensor (Outside Temperature Compensation)
3 = Modulating on Room and External Temperature sensors
4 = Disabled
Page 19
INSTALLER INSTRUCTIONS
12
6. Disabling thermo-regulation
In case the remote controller is installed inside a generic environment and you do not need to control its temperature (i.e.garage, boiler room…), you can disable the Central Heating demand request trough proper configuration of parameter P04 = 4 (see chapter 5 – Configurating operating parameters).
With this kind of configuration the word diS is displayed on the remote controller LCD screen in place of the room temperature.
Page 20
INSTALLER INSTRUCTIONS
13
7. Boiler configuration (TSP)
This operation must be carried out by Technical Assistance personnel exclusively.
The remote control device does not know the meaning of what appears on the display but only acts as a “graphic interface” for the boiler electronic board. The number of parameters to be set is transmitted via an Opentherm protocol. Move the remote control device to OFF
position, press keys and and keep them pressed for more than 10 seconds. Message will appear and flash on the display.
Release keys and , then press knob within 10 seconds to enable configuration. The display will now show the flashing parameter number in place of the time and the value associated to the parameter
in place of the temperature. Rotate knob to select the parameter number to display. The value associated to the various parameters will appear on the temperature display. Once the desired parameter has
been selected, press knob again: the parameter number will stop flashing whereas the value associated to the parameter will start flashing (temperature digits) to indicate that the value can be modified. Rotate
knob to modify the value shown on the display. Press knob once more to save the new value. If no key is pressed within 10 seconds, normal operation will be restored and the last change made will not be saved. To quit the configuration mode before the time has elapsed,
press key .
The list of parameters can vary according to the boiler model.
Please refer to the boiler instructions manual to configure the parameters required.
Page 21
USER INSTRUCTIONS
14
8. Selecting operating mode
Subject to the type of boiler connected, some of the following modes may not be available.
Select the operating mode of the boiler by pressing key several times. The operating modes you can set are:
SELECTED STATUS ID ICONS
OFF
SUMMER
WINTER
ONLY HEATING
1. OFF: all requests for boiler are disabled.
Page 22
USER INSTRUCTIONS
15
2. SUMMER: the boiler is enabled to only produce domestic hot water.
3. WINTER: the boiler is enabled to produce domestic hot water and to heat the room.
Page 23
USER INSTRUCTIONS
16
4. ONLY HEATING: the only operation mode enabled is heating.
No matter which function has been selected, the room anti-freeze function is always operative (cfr. respective section).
Page 24
USER INSTRUCTIONS
17
9. Setting up clock and temperature
Subject to the type of boiler connected, some of the following modes may not be available.
To set the clock and the temperature set points of this remote control
device and of the boiler press key several times.
The menu is as follows:
SELECTED STATUS ID ICONS
CLOCK
TEMPERATURE DAY
TEMPERTURE NIGHT
In place of the time, the quantity value is displayed in the lower left corner. Its identifying icon will be blinking. In order to conclude the
setting phase press key several times until all identifying icons are off.
Page 25
USER INSTRUCTIONS
18
9.1. Setting up clock
1. Press key : the hour will blink.
2. Turn button to set the requie value.
3. Press button to confirm the input value. The hour will stop blinking and the minutes will start blinking.
Page 26
USER INSTRUCTIONS
19
4. Turn button to set the value you want.
5. Press button to confirm value. The minutes stop blinking and the day of the week will start blinking.
6. Turn button to set the value you want.
7. Press button to confirm value. The day of the week stops blinking
and icon goes off.
Page 27
USER INSTRUCTIONS
20
9.2. Setting up room DAY temperature
1. Press key until icon starts blinking.
2. Turn button to set the value you want.
Page 28
USER INSTRUCTIONS
21
9.3. Setting up room NIGHT temperature
1. Press key and release when icon starts blinking.
2. Turn button to set the temperature you want.
Page 29
USER INSTRUCTIONS
22
9.4. Setting up HEATING temperature
If the remote control device has been configured as modulating, this parameter determines the max. temperature value as computed by the modulation algorithm.
1. Press key until icon starts blinking.
2. Turn button to set the value you want.
Page 30
USER INSTRUCTIONS
23
9.5. Setting up DOMESTIC HOT WATER temperature
1. Press key until icon starts blinking.
2. Turn button to set the value you want.
Page 31
USER INSTRUCTIONS
24
9.6. Setting up outside probe KD value
This setting option is available only if the outside probe is connected, the remote control device is set as modulating and the use of the outside probe for modulation (P04 = 2 or 3) is enabled.
This parameter allows to select a curve to determine the outside temperature – computed heating temperature ratio (see ‘Flow temperature calculation diagram’). The setting range is 0.0 to 3.0. The higher the set value, the greater the influence of the outside
temperature on the determination of the set heating temperature.
1. Press key until icon starts blinking.
2. Turn button to set the value you want.
Page 32
USER INSTRUCTIONS
25
Flow temperature calculation diagram
Page 33
USER INSTRUCTIONS
26
10. Setting up clock and temperatures
If the operation mode selected is WINTER or HEATING ONLY, the EASYREMOTE device allows you to manipulate the room temperature either MANUALLY or AUTOMATICALLY.
• In MANUAL mode the user selects the room temperature he wants, and this temperature will be maintained until a change is made.
• In AUTOMATIC mode the room temperature set point is determined by the correspondence between time-day and the set weekly program.
Page 34
USER INSTRUCTIONS
27
10.1. MANUAL operation
1. Press key until icon appears. The central digits on the display will show the set temperature blinking.
2. Turn button to set the temperature you want.
3. After 30 secs the central display will go back to showing the current temperature.
4. The set temperature can be changed again at any moment by turning
button .
5. The set temperature can be displayed by pressing key .
Page 35
USER INSTRUCTIONS
28
10.2. AUTOMATIC operation
1. Press button until the heating clock corona will be displayed.
2. Icon or will light up to show which is the currently set temperature level.
Page 36
USER INSTRUCTIONS
29
11. Weekly heating program
When operation mode WINTER or HEATING ONLY is selected, the remote control device allows operation in AUTOMATIC mode in which a priorly set program manages the room temperature during the various times of the day.
The room temperature can be set to two independent levels: DAY ( ) and NIGHT ( ); the weekly heating program distributes these levels over the day.
Inside the remote control device there is a standard program to control the room temperature; the user can display and change it as he likes
The display / change mode of the heating program will be actuated by
pressing key ; the lighting of icon PROG shows that it is on.
FUNCTION ID ICON
DISPLAY HEATING PROGRAM
PROG
steady
CHANGE HEATING
PROGRAM
PROG
blinking
After making the changes press key again to exit the programming area.
Page 37
USER INSTRUCTIONS
30
11.1. Display heating program
1. Press key . Icons PROG and will appear on the display and
show the first day of the week. Icons / and the jumper are ON
or OFF matching the DAY / NIGHT level of the displayed time.
2. Turn button in order to scroll the times of the day and to move from one day to another.
Page 38
USER INSTRUCTIONS
31
11.2. Change heating program
1. Press key . Icons PROG and will appear on the display and
show the first day of the week. Icons / and the jumper are ON
or OFF matching the DAY/NIGHT level of the displayed time.
2. Press button to go to the program change zone: icon PROG and the day of the week will blink.
3. Turn button to select the day you want.
4. Press button to confirm the day you selected and to move to the time. The day of the week will stop blinking and the time will start blinking.
5. Turn button to select the time you want.
6. Press key to change the temperature level DAY / NIGHT assigned to the current time.
7. Turn button until it shows the time period during which you want to keep the current level.
8. Press key to change the level and so on.
9. Repeat operations from point 2 on in order to change the day.
10. Press Key to quit the heating program.
Page 39
USER INSTRUCTIONS
32
12. Weekly storage tank program
This function is available only if the boiler connected to the remote control device has been designed to control it.
The EASYREMOTE remote control device can run (same as for heating
program) a weekly program to enable ( ) or disable ( ) the storage tank by time ranges.
Inside the remote control device there is a standard program to control the storage tank; the user can display and change it as he likes.
The storage tank program display / change mode is the same as the one
used for the heating program: it is actuated by pressing key and the
lighting up of icons PROG and shows that it is on.
Page 40
USER INSTRUCTIONS
33
12.1. Display storage tank program
1. Press key . Icons PROG and will appear on the display and show the first day of the week.
2. Press key . Icon will light up on the display and show the
storage tank program. Icon (storage tank enabled) or (storage
tank disabled) and the jumper are ON or OFF matching the level of the displayed time.
3. Turn button to scroll the times of the day and to move from one day to another.
Page 41
USER INSTRUCTIONS
34
12.2. Change storage tank program
1. Press key . Icons PROG and will appear on the display and show the first day of the week.
2. Press key . Icon will light up on the display and show the
storage tank program. Icons (storage tank enabled) or (storage
tank disabled) and the jumper are ON or OFF matching the level of the displayed time.
3. Press button to move to the program change zone: icon PROG and the day of the week will blink.
4. Turn button to select the day you want.
5. Press button to confirm the day you selected and to move to the time. The day of the week will stop blinking and the time will start blinking.
6. Turn button to select the time you want.
7. Press key to change boiler status ENABLED ( ) / DISABLED
( ) assigned to current time.
8. Turn button until it shows the time period for which you want to keep the current level.
9. Press key to change level and so on.
10. Repeat operations from point 3 on to change the day.
11. Press Key to quit the storage tank program.
Page 42
USER INSTRUCTIONS
35
13. Temporary change room temperature set point
When operating in AUTOMATIC mode the room set point DAY ( ) / NIGHT ( ) can be increased or reduced. The change will be valid until the next level change (DAY-NIGHT) takes place. Thereafter it will be void.
1. Press key to display the set room temperature.
2. Turn button to select the value. Icon will blink for the time of the change and shows that the change of the set point has been made.
If you want to disable the function before it has expired, disable the
heating function by pressing key .
Page 43
USER INSTRUCTIONS
36
14. Fault signalling
The remote control device will display any faults with code Exx blinking in place of the temperature display.
To learn about the type of fault refer to the boiler instruction booklet.
There can be two kinds of faults: those which can be restored by the user and those which cannot be restored.
14.1. Restorable faults
You recognize these faults because icon will light up and blink; they
can be reset by pressing key .
If there are no more restoring attempts available icon will stay on. In such a case, follow the steps of the boiler instruction and maintenance booklet. In case the fault remains on, contact the tecnica service center.
Page 44
USER INSTRUCTIONS
37
14.2. Not restorable faults
You recognize these faults because icon will light up; these faults cannot be reset by the user but require technical service. Also code E66 falls under this error class (room temperature probe of remote control device in fault).
Page 45
USER INSTRUCTIONS
38
15. Display values
Subject to the type of boiler connected some of the below described functions may not be available.
Pressing key repeatedly your EASYREMOTE control device is able to display the following quantity values:
SELECTED QUANTITY ID ICON
SET ROOM TEMPERATURE
DOMESTIC HOT WATER PROBE
TEMPERATURE
DELIVERY PROBE TEMPERATURE
OUTSIDE PROBE TEMPERATURE
Page 46
USER INSTRUCTIONS
39
15.1. Display set room temperature
This is the temperature set for the activated temperature level (DAY ­NIGHT - MANUAL).
15.2. Display temperature domestic hot water probe
This is the temperature read by the domestic hot water probe fitted in the boiler.
Page 47
USER INSTRUCTIONS
40
15.3. Display temperature delivery probe
This is the temperature read by the delivery probe fitted in the boiler.
15.4. Display temperature outside probe
This is the temperature read by the outside probe connected to the boiler.
Page 48
USER INSTRUCTIONS
41
16. Reset of default values
If necessary the original values of the remote control device as set by the manufacturer can be restored.
The restored values are as follows:
Temperature DAY: 20°C
Temperature NIGHT: 16°C
Temperature MANUAL: 20°C
Weekly heating program
Days NIGHT DAY
Monday - Friday
00.00 ÷ 06.00
08.00 ÷ 16.30
22.00 ÷ 00.00
06.00 ÷ 08.00
16.30 ÷ 22.00
Saturday - Sunday
00.00 ÷ 07.00
23.00 ÷ 00.00
07.00 ÷ 23.00
Page 49
USER INSTRUCTIONS
42
1. Move the remote control device to OFF position.
2. Press keys and and keep them pressed for longer than 5 secs.
3. The operation is confirmed when dEF appears on the display.
Page 50
USER INSTRUCTIONS
43
17. Complete resetting
Faults or other technical reasons may require ‘complete resetting’ of the remote control device.
For this operation the remote control device must be taken off its fixing template - do this by gently pressing with a screwdriver on the lower splines.
Thereafter press key (1).
After doing a “complete reset” the
time and day of the week must be set
again.
Page 51
USER INSTRUCTIONS
44
18. Funzione antigelo ambiente
The EASYREMOTE controller is able to support the room-antifrost function. In all the operating modes the central heating demand is generated whenever the measured room temperature is lower then the activation threshold (parameter P01). This grants protection of the central heating installation from the freezing risk. The function can be eventually disabled trough proper setting of parameter P01 (P01 = 0.0).
Page 52
RADIANT BRUCIATORI s.p.a.
Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU)
Tel. +39 0721 9079.1 fax. +39 0721 9079279
e-mail: tecnico@radiant Internet: http://www.radiant.it
THE TECHNICAL DATA AND MEASUREMENTS ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND ARE NOT BINDING. THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION. NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION ERRORS. E+OEALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED, MEMORISED IN ANY FILING SYSTEMS OR TRANSMITTED IN ANY FORM WHATSOEVER, INCLUDING ELECTRONIC, MECHANICAL, PHOTOCOPIES, RECORDINGS OR ANY OTHER MEANS WITHOUT THE COMPANY’S PRIOR WRITTEN APPROVAL.