RACOM RE400 Quick Start Manual

Page 1
Quick Start - RE400
6/1/2010
1. The first start of radio modem
Don’t connect radio modem in your LAN before settings! Default IP address of radio modem may be already used in your network.
Do not switch on more than one radio with default settings at any one time! Only switch on the next one after setting and storing IP parameters in the first one.
Switch on power (PoE or AUX). PWR and ETH LED have to light. After 20 sec. STATUS starts to blink in green.
Set IP and mask of your PC to 192.168.1.233, mask 255.255.255.0 (check user manual).
Start www browser on address 192.168.1.2.
Set radio modem configuration and Save it.
Select a unique IP address of each radio modem within the network.
When IP address is changed, conection with radio modem is lost. Next communication is possible after change of IP address in www browser, possibly in your PC.
1© RACOM s.r.o. – Quick Start - RE400
Page 2
Connect application to radio modem via ETH or SCC.
Communication is indicated by LEDs (see manual).
Before configuring the next radio delete table Art (Start, Run, arp -d) in the PC.
2. Connectors
2.1. Antenna
Fig. 1: Antenna connector SMA
There is a SMA-jack antenna connector on panel of radio modem. On your antenna cable use only respective type of connector of respective impedance: SMA-plug, 50 Ω. It is recommended to use antenna coaxial cables like this: RG58 up to 10 m, RG213 up to 25 m, H1000 for longer.
Radio modem may be destroyed when antenna or dummy load antenna is not connected!
2.2. Serial interface
Fig. 2: RS232, DSUB9 female
Tab. 1: RS232 - DSUB9F pins
signalpinsignalpin
DSR6CD1
RTS7RxD2
CTS8TxD3
+PWR9DTR4
GND5
2.3. Ethernet interface
Fig. 3: RJ-45F
Ethernet connector RJ-45 for 10BaseT and 100BaseT meets fully standard of Power over Etrhernet IEEE802.3af.
Radio modem recognizes standard or cross cable and adapts itself automatically.
2.4. Power suply - possibilities
AUX – via RS232 DSUB9 connector, using pins 5 and 9 (see Tab.1). Voltage 10,5–30 V, nominal 13,8 V.
PoE – via Ethernet connector RJ-45 using PoE standard IEEE802.3af. Voltage 38–57 V. Common version of supplying:
plus to pins 4+5 minus to pins 7+8 the polarity can be inverted also
Other options with PoE adapter see the standard IEEE802.3af.
! Only ONE from above power possibilities can be used !
Quick Start - RE400 – © RACOM s.r.o.2
Quick Start - RE400
Page 3
2.5. Indication LEDs Appearance of radio modem
Fig. 4: Appearance of radio modem
LED meanings
PWR Yellow – AUX (power via RS232)
Green – PoE (power via Ethernet)
TX Red - transmitting
RX Green – RF sync
Yellow – there is a signal stronger then -80 dBm on radio channel
ETH Yellow – connected with 100 Mb/s speed
Yellow blinking – data transfer with speed of 100 Mb/s
Green - connected with 10 Mb/s speed
Green blinking – data transfer with speed of 10 Mb/s
232 Green – data receiving
Yellow – data transmitting
STATUS status of operating system
Green blinking with period 2 sec ON, 1 sec OFF – main mod
Yellow blinking with period 1 sec ON, 1 sec OFF – Service mode
Yellow blinking with period 0,2 sec ON, 0,2 sec OFF – Bootloader mode
3© RACOM s.r.o. – Quick Start - RE400
Quick Start - RE400
Page 4
3. Table of Technical Parameters
Tab. 2: Technical parameters
RE400: 373.25–484 MHzFrequency range
25 kHz or 12.5 kHz or 6.25 kHz *Channel bandwith
5 kHz or 6.25 kHzFrequency step
softwareMethod of setting working frequency
< 1.5 msRx/Tx switching time
32 bit CRCData security on RF channel
better than -107 dBmReceiver sensitivity for BER 10
-3
0.5 WLow
Output power software adjustable
2 WHigh
2.6 kbps in 6.25 kHz channel *
Data rate in RF channel 5.2 kbps in 12.5 kHz channel
10.4 kbps in 25 kHz channel
Ethernet, RS232Interfaces
SMAAntenna connector
>100 000 hodinMTBF (Mean Time Between Failures)
PoEAUXPower method
38–57 V10.8–30 V (nomin. 13.8 V)Power supply
145 mA/48 V430 mA/13.8 VIdle state (Rx)
Power consumption (cca)
230 mA/48 V700 mA/13.8 VLow power Tx
310 mA/48 V950 mA/13.8 VHigh power Tx
-25 až +55 °COperating temperature range
-35 až +85 °CStorage temperature range
137 × 96 × 31 mmCase dimensions
0.3 kgWeight
* Channel spacing 6.25 kHz is not approved under EU rules.
Quick Start - RE400 – © RACOM s.r.o.4