Rackmount ICX7250-48P Data sheet

Page 1
Brocade ICX 7250
Enterprise-Class Stackable Access Switch
DATA SHEET
ENTERPRISE-CLASS SWITCH WITH FUTURE-PROOF EXPANDABILITY
The Brocade® ICX® 7250 switch combines enterprise-class features, manageability and the exibility and “pay as you grow” scalability of a stackable solution. The switch delivers the performance required for enterprise Gigabit Ethernet (GbE) access deployment. It raises the bar with up to 8×10 GbE ports for uplinks or stacking and market-leading stacking density with up to 12 switches (576×1 GbE) per stack. Brocade ICX
7250 switches also oer an external power supply for failover resiliency, as well as increased PoE/PoE+ port availability.
The Brocade ICX 7250 is easy to deploy, manage, and integrate into both new and existing networks. Organizations can buy only what they need today, and easily scale out as demand grows and new technologies emerge. Optimizing performance based on specic requirements is easy with exible licensing upgrade which allows users to upgrade from 1 GbE to 10 GbE ports for uplink and stacking.
Deployed as a standalone switch, a stack, or a network fabric, organizations reap the benets of a exible platform and the assurance that their
investments are protected.
BROCADE ICX 7250 SWITCHES
Except as noted, all Brocade ICX 7250 models oer eight uplink/stacking ports, a single integrated power supply and fan, one RJ-45 network
management port, one mini USB serial management port, and one USB storage port on the front panel.
Brocade ICX 7250-24G
24×10/100/1000 Mbps RJ-45 ports 4×1 GbE uplink ports; Not upgradable No EPS connector Premium Layer 3 licenses not applicable
Brocade ICX 7250-24
24×10/100/1000 Mbps RJ-45 ports 8×1 GbE uplink/stacking ports; Upgradable to 10 GbE
Brocade ICX 7250-24P
24×10/100/1000 Mbps RJ-45 PoE+ ports 370 W PoE budget 8×1 GbE uplink/stacking ports; Upgradable to 10 GbE
Brocade ICX 7250-48
48×10/100/1000 Mbps RJ-45 ports 8×1 GbE uplink/stacking ports; Upgradable to 10 GbE
Brocade ICX 7250-48P
48×10/100/1000 Mbps RJ-45 PoE+ ports 740 W PoE budget 8×1 GbE uplink/stacking ports; Upgradable to 10 GbE
© 2017 RUCKUS WIRELESS, INC
1
Page 2
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
BROCADE ICX 7250 FEATURE/MODEL COMPARISON
24 RJ-45 Ports 24 or 48 Ports (Non-PoE) 24 or 48 PoE+ Ports
DATA SHEET
FE AT U RE
Switching capacity
(data rate, full duplex)
Forwarding capacity
(data rate, full duplex)
Fixed ports: 10/100/1000 Mbps RJ-45
Fixed ports: 100/1000 Mbps SFP 4
Fixed ports: 1/10 Gbps SFP+
(10 GbE SPF+ optional upgrade
license)
PoE/PoE+ ports 24 48
Maximum PoE Class 3 ports
(15.4 W per port with internal AC
power supply only)
Maximum PoE+ ports
(30 W per port, with internal AC power
supply only)
Maximum PoE+ Class 4 ports
(30 W per port with external power
supply)
Brocade ICX
7250-24G
128 Gbps 208 Gbps 256 Gbps 208 Gbps 256 Gbps
96 Mpps 154 Mpps 190 Mpps 154 Mpps 190 Mpps
24 24 48 24 48
Brocade ICX
7250-24
8 8 8 8
Brocade ICX
7250-48
Brocade ICX
7250-24P
24 48
12 24
24 48
Brocade ICX
7250-48P
Base IPv4/IPv6 Layer 3 routing
(static routing)
Advanced IPv4/IPv6 Layer 3 routing
(RIP, OSPF, VRRP, PIM, PBR, VRF
features)
Aggregated stacking bandwidth 480 Gbps 480 Gbps 480 Gbps 480 Gbps
Stacking density
(maximum switches in a stack)
Stacking ports
(maximum ports1 usable for stacking)
Maximum stacking distance (distance between stacked switches)
With license With license With license With license
12 12 12 12
Up to 4×10 GbE SFP+ per switch
10 km 10 km 10 km 10 km
1
10 Gbps SFP+ ports are required for stacking.
© 2017 RUCKUS WIRELESS, INC.
2
Page 3
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
BROCADE ICX 7250 FEATURE/MODEL COMPARISON
24 RJ-45 Ports 24 or 48 Ports (Non-PoE) 24 or 48 PoE+ Ports
DATA SHEET
Brocade ICX
7250-24G
FE AT U RE POWER
Power inlet (AC) C14
Input voltage/frequency AC: 100 to 240 VAC @ 50 to 60 Hz
Maximum current draw
(at 100 VAC, one power supply)
Power supply rated maximum (AC) 135 W 135 W 135 W 525 W 880 W
PoE power budget (AC)
(internal AC power supply only)
Switch power consumption (25°C) Idle (no PoE load)
10% trac2 (full PoE load) 100% trac2 (full PoE load)
Airow Front-to-back Side-to-back Side-to-back Side-to-back Side-to-back
Switch heat dissipation (25°C)3 Idle (no PoE load)
10% trac2 (full PoE load) 100% trac2 (full PoE load)
FE AT U RE ENVIRONMENT
1.69 Amp 1.69 Amp 1.69 Amp 6.56 Amp 11 Amp
N/A N/A N/A 370 W 740 W
33.6 W
42.6 W
44.4 W
114.6 BTU/hour
145.3 BTU/hour
151.4 BTU/hour
Brocade ICX
7250-24
42.6 W
51.6 W
57.6 W
145.3 BTU/hour
176.06 BTU/hour
196.5 BTU/hour
Brocade ICX
7250-48
50.64 W
63.55 W
69.51 W
172.7 BTU/hour
216.8 BTU/hour
237.1 BTU/hour
Brocade ICX
7250-24P
50 W
63 W 73 W
170.6 BTU/hour
214.9 BTU/hour
249.08 BTU/hour
Brocade ICX
7250-48P
66 W
84 W
96 W
225.2 BTU/hour
286.6 BTU/hour
327.5 BTU/hour
Weight (kg) 3.58 3.76 4.84 4.73 5.86
Dimensions 48 port: 440 mm (17.323 in.), W×370 mm (14.56 in.), D×43.7 mm (1.720 in.), H — 1U
Acoustics (25°C) 40 dB 41.9 dB 44.5 dB 44.7 dB 45.9 dB
MTBF (hours) (25°C) 767,718 676,362 665,319 429,209 411,187
24 port: 440 mm (17.323 in.), W×280 mm (11.02 in.), D×43.7 mm (1.720 in.), H — 1U
2
Trac load on all ports connec ted with maximum possible PoE/PoE+ loads (if equipped). PoE power de livered to powered devices not included.
3
PoE power not included in switch heat dissipation gures since the heat is not dissipated at th e switch.
© 2017 RUCKUS WIRELESS, INC.
3
Page 4
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
BROCADE ICX 7250 SPECIFICATIONS
FE AT U RES SPECIFICATIONS
Connector options 10/100/1000 ports: RJ-45
1 GbE SFP ports (Brocade ICX 7250-24G only)
1/10 GbE SFP+ ports (not available on Brocade ICX 7250-24G)
Out-of-band Ethernet management: 10/100/1000 Mbps RJ-45
Console management: Mini-USB serial port (Mini-B plug)
File transfer: USB port (Standard-A plug)
For the latest information about supported optics, please visit www.ruckuswireless.com/optics.
DATA SHEET
DRAM NVRAM (Flash)
Packet buer size
Maximum MAC addresses 16,384
Maximum VLANs Maximum PVLANs
Maximum STP (spanning trees) 254
Maximum VEs 255
Maximum routes (in hardware)
Trunking Maximum ports per trunk: 16
Maximum jumbo frame size 9,216 bytes
Average latency 1.5 µs
QoS Priority Queues 8 per port
Multicast Groups 8,192 (Layer 2)
FE AT U RES FE AT U RE SETS
2 GB (except for ICX 7250-24G: 1 GB)
2 GB (except for ICX 7250-24G: 1 GB)
24 port: 2 MB, 48 port: 4 MB
4,096
32
12,000 (IPv4)
2,048 (IPv6)
7000 (Next Hop Addresses)
Maximum trunk groups: 128
8,192 (Layer 3)
Layer 2 switching 802.1s Multiple Spanning Tree
802.1x Authentication
Auto MDI/MDIX
BPDU Guard, Root Guard
Dual-Mode VLANs
MAC-based VLANs, Dynamic MAC-based
VLAN activation
Dynamic VLAN Assignment
Dynamic Voice VLAN Assignment
Fast Port Span
GVRP: GARP VLAN Registration Protocol
IGMP Snooping (v1/v2/v3)
IGMP Proxy for Static Groups
IGMP v2/v3 Fast Leave
IGMP Tracking
Inter-Packet Gap (IPG) adjustment
Link Fault Signaling (LFS)
MAC-Address Filtering
© 2017 RUCKUS WIRELESS, INC.
MAC Learning Disable
MLD Snooping (v1/v2)
Multi-device Authentication
Per-VLAN Spanning Tree (PVST/PVST+/PVRST)
Mirroring—Port-based, ACL-based, MAC Filter-based,
and VLAN-based
PIM-SM v2 Snooping
Port Loop Detection
Private VLAN
Remote Fault Notication (RFN)
Single-instance Spanning Tree
Trunk Groups (static, LACP)
Uni-Directional Link Detection (UDLD)
Metro-Ring Protocol MRP (v1, v2)
Virtual Switch Redundancy Protocol (VSRP)
Topology Groups
Q-in-Q
4
Page 5
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
BROCADE ICX 7250 SPECIFICATIONS
DATA SHEET
Base Layer 3 IP routing IPv4 and IPv6 static routes
ECMP
Port-based Access Control Lists
Layer 3/Layer 4 ACLs
Host routes
Premium Layer 3 IP routing IPv4 and IPv6 dynamic routes
OSPF v2, v3
PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4/IPv6
multicast routing functionality)
PBR
Virtual Route Redundancy Protocol (VRRP)
Quality of Service (QoS) ACL Mapping and Marking of ToS/DSCP
ACL Mapping and Marking of 802.1p
ACL Mapping to Priority Queue
Classifying and Limiting Flows Based on TCP Flags
DiServ Support
Honoring DSCP and 802.1p
Trac management ACL-based inbound rate limiting and trac policies
Broadcast, multicast, and unknown unicast rate limiting
Security 802.1X Accounting
MAC Authentication
Flexible authentication
Web authentication
DHCP snooping
Dynamic ARP inspection
ND Inspection (Neighbor Discovery)
Bi-level Access Mode (Standard and EXEC Level)
EAP pass-through support
IEEE 802.1X username export in sFlow
Virtual interfaces
Routed interfaces
Route-only support
Routing between directly connected subnets
VRRP-E (IPv4/IPv6)
VRRP v3 (IPv6)
IPv6 over IPv4 tunnels
VRF (IPv4 and IPv6)
RIP v1/v2, RIPng
MAC Address Mapping to Priority Queue
Priority Queue Management using Weighted Round
Robin (WRR), Strict Priority (SP), and a combination of WRR and SP
Priority Flow Control
Inbound rate limiting per port
Outbound rate limiting per port and per queue
Protection against Denial of Service (DoS) attacks
Authentication, Authorization, and Accounting (AAA)
MAC Address Locking; MAC Port Security
Advanced Encryption Standard (AES) with SSHv2
RADIUS/TACACS/TACACS+
Secure Copy (SCP)
Secure Shell (SSHv2)
Username/Password
Change of Authorization (CoA) RFC 5176
SDN features Support for OpenFlow v1.0 and v1.3 OpenFlow support with true hybrid port mode
IEEE standards compliance 802.1AB LLDP/LLDP-MED
802.1D-2004 MAC Bridging
802.1p Mapping to Priority Queue
802.1s Multiple Spanning Tree
802.1w Rapid Reconguration of Spanning Tree (RSTP)
802.1x Port-based Network Access Control (PNAC)
802.3 Carrier Sense Multiple Access/Collision Detection
(CSMA/CD)
802.3ab 1000Base-T
802.3 10Base-T
802.3ad Link Aggregation (Dynamic and Static)
RFC standards compliance For a complete list of RFCs supported by the Ruckus ICX 7000 product family, please consult the “FastIron Features and
Standards Support Matrix” document available from support.ruckuswireless.com..
High availability Layer 3 VRRP protocol redundancy
Real-time state synchronization across the stack
Hitless failover from master to standby stack controller
802.1 AX-2008 Link Aggregation
802.3ae 10 GbE
802.3af Power over Ethernet
802.3at Power over Ethernet Plus
802.3u 100Base-TX
802.3x Flow Control
802.3z 1000Base-SX/LX
802.3 MAU MIB (RFC 2239)
802.3az-2010 – Energy Ecient Ethernet (EEE)
802.1Q VLAN Tagging
802.1BR Bridge Port Extension
Hot insertion and removal of stacked units
Layer 2 VSRP switch redundancy
In-Service Software Update (ISSU)
© 2017 RUCKUS WIRELESS, INC.
5
Page 6
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
BROCADE ICX 7250 SPECIFICATIONS
FE AT U RES NETWORK AND DEVICE MANAGEMENT
DATA SHEET
Management DHCP Auto Conguration
Conguration Logging
Digital Optical Monitoring
Display Log Messages on Multiple Terminals
Embedded Web Management (HTTP/HTTPS)
Embedded DHCP Server
Industry-standard Command Line Interface (CLI)
Brocade Network Advisor (sold separately)
Key-based activation of optional software features
USB le management and storage
Macro for batch execution
Out-of-band Ethernet Management
ERSPAN support for remote trac monitoring
TFTP
TELNET Client and Server
Bootp
Ruckus Campus Fabric technology
Brocade ICX 7250 can operate in fabric Port Extender
(PE) mode
SNMPv1/v2c
DHCP Server and DHCP Relay
SNMPv3 Intro to Framework
Architecture for Describing SNMP Framework
SNMP Message Processing and Dispatching
SNMPv3 Applications
SNMPv3 User-based Security Model
SNMP View-based Access Control Model SNMP
sFlow
NTP Network Time Protocol
Multiple Syslog Servers
SCP
Virtual Cable Tester (VCT)
For Management MIB, please consult the “FastIron
MIB Reference” document available from support.
ruckuswireless.com.
Zero-touch provisioning
High availability with ring topology
Up to 36 PEs per fabric
PE Cascade depth up to 6 units
FE AT U RES ENVIRONMENT
Temperature Operating temperature: -5°C to 50°C/23°F to 122°F
Storage temperature: −25°C to 70°C/−13°F to 158°F
Humidity Operating relative humidity: 5% to 95% at 50°C, non-condensing
Non-operating relative humidity: 0% to 95% at 70°C, non-condensing
Altitude Operating altitude: 10,000 ft (3,000 m) maximum
Storage altitude: 39,000 ft (12,000 m) maximum
FE AT U RES COMPLIANCE/CERTIFICATION
Electromagnetic emissions FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS
Safety CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006
Immunity EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics
Environmental regulatory compliance
Vibration IEC 68-2-36, IEC 68-2-6
Shock and drop IEC 68-2-27, IEC 68-2-32
55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3
Emission Standard (supersedes: EN 50081-1)
Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classication, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication
Systems
(supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags
RoHS-compliant (6 of 6); WEEE-compliant
© 2017 RUCKUS WIRELESS, INC.
6
Page 7
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
BROCADE ICX 7250 ORDERING INFORMATION
PART NUMBER BROCADE ICX 7250 SWITCHES WITH 1 GBE UPLINKS
DATA SHEET
ICX7250-24G Brocade ICX 7250 Switch, 24×10/100/1000 ports, 4×1 GbE SFP uplink ports (non-upgradable), Layer 2 only, front-to-
ICX7250-24 Brocade ICX 7250 Switch, 24×10/100/1000 ports, 8×1 GbE SFP upgradable to up to 8×10 GbE SFP+ uplink/stacking-
ICX7250-24P Brocade ICX 7250 Switch, 24×10/100/1000 PoE+ ports, 8×1 GbE SFP upgradable to up to 8×10 GbE SFP+ uplink/
ICX7250-48 Brocade ICX 7250 Switch, 48×10/100/1000 ports, 8×1 GbE SFP upgradable to up to 8×10 GbE SFP+ uplink/stacking-
ICX7250-48P Brocade ICX 7250 Switch, 48×10/100/1000 PoE+ ports, 8×1 GbE SFP upgradable to up to 8×10 GbE SFP+ uplink/
PART NUMBER BROCADE ICX 7250 SWITCHES WITH 2×10 GBE UPLINKS
ICX7250-24-2X10G Brocade ICX 7250 Switch, 24×10/100/1000 ports, 6×1 GbE SFP and 2×10 GbE SFP+ uplink/stacking-ports upgradable
ICX7250-24P-2X10G Brocade ICX 7250 Switch, 24×10/100/1000 PoE+ ports, 6×1 GbE SFP and 2×10 GbE SFP+ uplink/stacking-ports
ICX7250-48-2X10G Brocade ICX 7250 Switch, 48×10/100/1000 ports, 6×1 GbE SFP and 2×10 GbE SFP+ uplink/stacking-ports upgradable
ICX7250-48P-2X10G Brocade ICX 7250 Switch, 48×10/100/1000 PoE+ ports, 6×1 GbE SFP and 2×10 GbE SFP+ uplink/stacking-ports
PART NUMBER
back airow, no EPS connector
ports with license, basic Layer 3 (static routing), side-to-back airow
stacking-ports with license, 370 W PoE budget, basic Layer 3 (static routing), side-to-back airow
ports with license, basic Layer 3 (static routing), side-to-back airow
stacking-ports with license, 740 W PoE budget, basic Layer 3 (static routing), side-to-back airow
to up to 8×10 GbE SFP+ with license, basic Layer 3 (static routing), side-to-back airow
upgradable to up to 8×10 GbE SFP+ with license, 370 W PoE budget, basic Layer 3 (static routing), side-to-back airow
to up to 8×10 GbE SFP+ with license, basic Layer 3 (static routing), side-to-back airow
upgradable to up to 8×10 GbE SFP+ with license, 740 W PoE budget, basic Layer 3 (static routing), side-to-back airow
BROCADE ICX-EPS 4000 EXTERNAL POWER SUPPLY OPTIONS FOR THE BROCADE ICX 7250 SWITCH
The Brocade ICX-EPS4000 supports up to four removable power supplies. Each power supply provides 920 W.
ICX-EPS4000-SHELF 1U External Power Supply shelf (EPS) can support up to four 920 W removable power supplies (purchased separately).
RPS17 EPS power supply, 920 W
ICX-EPS4000-CBL-01 Brocade ICX-EPS4000 power cable 1:1
ICX-EPS4000-CBL-02 Brocade ICX-EPS4000 power cable 1:2
PART NUMBER UPGRADE LICENSES AND ACCESSORIES
ICX7250-PREM-LIC License to upgrade any Brocade ICX 7250 (except ICX7250-24G) to Layer 3 Premium Features (RIP, OSPF, VRRP, PIM,
ICX7250-2X10G-LIC-POD License to upgrade any Brocade ICX 7250 (except ICX7250-24G) from 8×1 GbE SFP to 6×1 GbE SFP and 2×10 GbE
ICX7250-8X10G-LIC-POD License to upgrade any Brocade ICX 7250 (except ICX7250-24G) from 6×1 GbE SFP and 2×10 GbE SFP+ to 8×10 GbE
ICX7000-RMK FRU, rack mount kit, two-post, Brocade ICX 7250/7450/7750
XBR-R000295 FRU, rack mount kit, four-post, 24 in. to 32 in. depth rack
BR-NTWADV-IP-BASE Brocade Network Advisor IP management software license for up to 50 devices; required for initial purchase of IP-only
PBR, VRF), non-node lock license.
SFP+ uplink/stacking ports, node-lock license.
SFP+ uplink/stacking ports, node-lock license. Only switches that already have 2×10 GbE ports can be upgraded to 8×10 GbE ports.
management; minimum of one year of support required
© 2017 RUCKUS WIRELESS, INC.
7
7
Page 8
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
BROCADE ICX 7250 ORDERING INFORMATION
PART NUMBER OPTICS (FOR BROCADE ICX 7250-24G ONLY)
DATA SHEET
E1MG-BXD 1000BASE-BXD SFP optic SMF, transmits at 1,490 nm and receives at 1,310 nm, LC connector, single-strand SMF
E1MG-BXU 1000BASE-BXU SFP optic SMF, transmits at 1,310 nm and receives at 1,490 nm, LC connector, single-strand SMF
E1M G - L H A - OM-T 1000BASE-LHA SFP optic, SMF, LC connector, optical monitoring-capable (70 km), industrial temperature
E1MG-L X-OM 1000BASE-LX SFP optic, SMF, LC connector, optical monitoring-capable
E1MG-SX-OM 1000BASE-SX SFP optic, MMF, LC connector, optical monitoring-capable
E1M G -T X 1000BASE-TX SFP copper, RJ-45 connector
Optics For Brocade ICX 7250-24/24P/48/48P
10G-SFPP-ER 10GBASE-ER SFP+ optic (LC), for up to 40 km over SMF
10G-SFPP-LR 10GBASE-LR, SFP+ optic (LC), for up to 10 km over SMF
10G-SFPP-SR 10GBASE-SR, SFP+ optic (LC), target range 300 m over MMF
10G-SFPP-USR 10GE USR SFP+ optic (LC), target range 100 m over MMF, 1-pack
10G-SFPP-ZR 10GBASE-ZR SFP+ optic (LC), for up to 80 km over SMF
E1MG-BXD 1000BASE-BXD SFP optic SMF, transmits at 1,490 nm and receives at 1,310 nm, LC connector, single-strand SMF
E1MG-BXU 1000BASE-BXU SFP optic SMF, transmits at 1,310 nm and receives at 1,490 nm, LC connector, single-strand SMF
E1M G - L H A - OM-T 1000BASE-LHA SFP optic, SMF, LC connector, optical monitoring-capable (70 km), industrial temperature
ber. This optic should only be connected to an E1MG-BXU at the far end.
ber. This optic should only be connected to an E1MG-BXD at the far end.
ber. This optic should only be connected to an E1MG-BXU at the far end.
ber. This optic should only be connected to an E1MG-BXD at the far end.
E1MG-L X-OM 1000BASE-LX SFP optic, SMF, LC connector, optical monitoring-capable
E1MG-SX-OM 1000BASE-SX SFP optic, MMF, LC connector, optical monitoring-capable
E1M G -T X 1000BASE-TX SFP Copper, RJ-45 connector
Direct-Attached Cables For Brocade ICX 7250-24/24P/48/48P
10G-SFPP-TW X-0101 Direct-attached SFP+ copper cable, 1 m, 1-pack, active
10G-SFPP-TWX-0301 Direct-attached SFP+ copper cable, 3 m, 1-pack, active
10G-SFPP-TWX-0501 Direct-attached SFP+ copper cable, 5 m, 1-pack, active
10GE-SFPP-AOC- 0701 10 GbE SFP+ direct-attached active optical cable, 7m, 1-pack
10GE-SFPP-AOC-1001 10 GbE SFP+ direct-attached active optical cable, 10 m, 1-pack
1G-SFP-TWX-0101 Direct-attached 1 GbE SFP copper cable, 1 m
1G-SFP-TWX-0501 Direct-attached 1 GbE SFP copper cable, 5 m
For a list of cables and ber optics approved for stacking, visit www.ruckuswireless.com/optics.
© 2017 RUCKUS WIRELESS, INC.
8
Page 9
Brocade ICX 7250
DATASHEET
Enterprise-Class Stackable Access Switch
DATA SHEET
ORDERING NOTES
Customers have two options when ordering a Brocade ICX 7250
switch. They can order one of the ve Brocade ICX 7250 switch models with 1 GbE uplink/stacking ports, or order a switch preloaded with a PoD license for two 10 GbE uplink/stacking ports.
The Brocade ICX 7250 (-24/-24P/-48/-48P) can be upgraded to 2×10 GbE uplink/stacking ports by purchasing a PoD license (ICX7250-2X10G-LIC-POD).
A Brocade ICX 7250 switch with 2×10 GbE uplink/stacking ports can be upgraded to 8×10 GbE by purchasing an additional PoD license (ICX7250-8X10G-LIC-POD). Only switches that already have
2×10 GbE can be upgraded to 8×10 GbE.
Note that the Brocade ICX 7250-24G switch is not upgradable and will support 4×1 GbE uplink ports only.
All Brocade ICX 7250 switches come with a power cord, two-post rack mounting brackets, and a USB serial console cable. Stacking cables and optics must be ordered separately.
WARRANTY
Brocade ICX 7250 Switches are covered by the Ruckus Assurance
Limited Lifetime Warranty. For details, visit www.ruckuswireless.com/
warranty.
LEGAL DISCLAIMER
Product features, functionality and specications may change or be
discontinued without notice. Nothing in this document shall be
deemed to create a warranty of any kind, either express or implied,
statutory or otherwise, including but not limited to, any implied
warranties of merchantability, tness for a particular purpose, non-
infringement of third-party rights or availability with respect to any products and services.
Refer to www.ruckuswireless.com for the latest version of this document.
Notice: This document is for informational purposes only and does
not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service oered or to be oered by
Ruckus. Ruckus reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that
may not be currently available. Contact a Ruckus sales oce for information on feature and product availability. Export of technical data contained in this document may require an export license from the
United States government.
BEST-IN-CLASS SUPPORT
Brocade ICX 7250 switches come with 3 years of free technical support from the Ruckus Technical Assistance Center (TAC). For continued access to the TAC past the initial 3 years, customers must purchase a Ruckus Technical Support contract. For details, visit
support.ruckuswireless.com/programs.
Copyright © 2017, Ruckus Wireless, Inc. All rights reserved. Ruckus Wireless and Ruckus Wireless design are registered in the
U.S. Patent and Trademark Ofce. Ruckus Wireless, the Ruckus Wireless logo, BeamFlex, ZoneFlex, MediaFlex, FlexMaster, ZoneDirector, SpeedFlex, SmartCast, SmartCell, ChannelFly and Dynamic PSK are trademarks of Ruckus Wireless, Inc. in the
United States and other countries. All other trademarks mentioned in this document or website are the property of their respective owners. 17-8-B
Ruckus Wireless, Inc. | 350 West Java Drive | Sunnyvale, CA 94089 USA | T: (650) 265-4200 | F: (408) 738-2065 ruckuswireless.com
Loading...