This documentation is provided for reference purposes only. While efforts were
made to verify the completeness and accuracy of the information contained in this
documentation, this documentation is provided "as is" without any warranty
whatsoever and to the maximum extent permitted. Pyrologic disclaims all implied
warranties, including without limitation the implied warranties of merchantability,
non-infringement and fitness for a particular purpose, with respect to the same,
Pyrologic shall not be responsible for any damages, including without limitation,
direct, indirect, consequential or incidental damages, arising out of the use of, or
otherwise related to, this documentation or any other documentation.
Notwithstanding anything to the contrary, nothing contained in this documentation or
any other documentation is intended to, nor shall have the effect of, creating any
warranties or representations from Pyrologic.
To the maximum extent permitted by applicable law, in no event shall Pyrologic be
liable for any damages whatsoever (including direct or indirect damages, loss of
business profits, lost savings or other special, incidental, exemplary or consequential
damages whether for breach of warranty, contract, strict liability, tort or otherwise)
arising out of or resulting from the use of or inability to use the products and/or the
enclosed written materials, even if Pyrologic have been advised of the possibility of
such damages or of any claim by any third party. In any event, any liability of
Pyrologic shall be limited to the purchase price of the product.
Warranty
Pyrologic warrants that the product will be free from defects in materials and
workmanship after the date of purchase, for the period of one (1) year. If Pyrologic
receives notice of such defects during the warranty period, Pyrologic will, at its
option, either repair or replace products which prove to be defective. Replacement
products may be either new or equivalent in performance to new.
Pyrologic does not warrant that the operation of Pyrologic products will be
uninterrupted or error free. If Pyrologic is unable, within a reasonable time, to repair
or replace any product to a condition as warranted, you will be entitled to a refund of
the purchase price upon prompt return of the product.
This warranty does not cover products that have been modified, refurbished,
remanufactured, misused, or tampered with in any way.
TO THE EXTENT ALLOWED BY LOCAL LAW, THE ABOVE WARRANTIES
ARE EXCLUSIVE AND NO OTHER WARRANTY OR CONDITION,
WHETHER WRITTEN OR ORAL, IS EXPRESSED OR IMPLIED AND
PYROLOGIC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OR
CONDITIONS OF MERCHANTABILITY, SATISFACTORY QUALITY, AND
FITNESS FOR A PARTICULAR PURPOSE.
b
The FCC Wants You to Know
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and receiver.
c) Connect the equipment to an outlet on a circuit different from that
to which the receiver is connected.
d) Consult the dealer or an experienced radio/TV technician.
FCC Warning
Modifications not expressly approved by the manufacturer could
void the user authority to operate the equipment under FCC Rules.
Instructions concerning human exposure to radio frequency
electromagnetic fields.
To comply with FCC Section1.307(b)(1) for human exposure to
radio frequency electromagnetic fields, implement the following
instruction:
The equipment user should keep a distance of at least 20 cm.
between the equipment antenna and his body or any other person.
Congratulations for purchasing the Pyrologic 2000 wireless fireworks shooting
system. We trust you will enjoy the unique features of this unparalleled system. The
following instructions will familiarize you with the features and operation of this
friendly system.
Thank you for choosing Pyrologic.
General information
Pyrologic 2000 is a wireless firework shooting system. Using a central Terminal Unit
(TU), a multitude of Remote Control Units (RCU's) are controlled by a coded Radio
Frequency link in order to fire upon command a firework electrically connected to
each RCU of choice.
The TU, either hand-held or installed into a BU, must be operated at a minimum
height of 0.6 meter from ground. The RCU must be installed at a minimum height of
0.6 meter from ground. Under such conditions the effective range between the TU
and any RCU is maximum 65 meters.
By connecting an Extension Unit (XU) to the BU using a standard telephone cable,
the RCU's can be controlled by the TU via the XU. The XU must be operated at a
minimum height of 0.6 meter from ground. The RCU must be installed at a minimum
height of 0.6 meter from ground. Under such conditions the effective range between
the XU and any RCU is maximum 65 meters.
System Components Definition
• Terminal Unit (TU)
• Terminal Unit Master Key (MK)
• Base Unit (BU)
• Extension Unit (XU)
• External PTT (XPTT)
• Remote Controlled Unit (RCU)
• Remote Controlled Unit for controlling 16 extensions (RCU-16).
1
Introduction
Basic System Characteristics
The normal operating range of the Pyrologic-2000 system is 65 meters from TU to
RCU. This range can be extended by connecting an XU to a BU to which a TU is
mounted. When mounting TU to BU, an XPTT can be attached to the BU. The range
extension is in accordance to the length of the extension cable of the XU connecting
between the BU to the XU. The RCUs are assigned to the TU by individual
programming communicated through the one-way RF link between TU and RCU.
Subsequently the operation of the RCUs is controlled by the TU through a one-way
RF link between TU and RCU, or alternatively by a wired link between the BU onto
which the TU is mounted and the XU, continued by a one-way RF link between XU
and RCU.
The system operates at the 418 MHz frequency and has been designed to comply
with the applicable FCC regulations (pending approval).
2
Safety and Operational Instructions
Safety and Operational Instructions
The operation of fireworks or pyrotechnics when using the Pyrologic 2000 system is
identical to operation using appropriate wiring instead of the RF command link. All
applicable laws and regulations regarding fireworks operation must be strictly
adhered.
When you purchase the system the RCUs are in generic state. The RCUs have to be
assigned to a specific TU Master Key according to the instructions detailed in this
manual.
When using the system for the first time and until you have learned to operate the
system correctly, please attach LEDs instead of squibs to the RCU squib connections
and otherwise operate the system according to the standard operation instructions, in
order to verify that you have mastered each and every detail of system operation.
Under no circumstances open or tamper the system components. Warranty will void
if any unauthorized attempt will be done to open or tamper system units.
Coping with External Transmission Disturbances: Pyrologic 2000 is a wireless
system that is designed according to the FCC regulations. Please check the system to
verify that there is no external interference. UNDER NO CIRCUMSTANCES THE
SYSTEM WILL FIRE WITHOUT OPERATOR COMMAND.
3
Getting started
Getting started
System Components
Terminal Unit
c
d
i
h
e
j
k
f
c Foldable Antenna
d Display
e Terminal Unit PTT Switch
f Master Key
g Base Unit Connector
h Terminal Unit Panel:
i Command Keys with Command Key LEDs
j Activation Keys with Control LEDs
k Programming Keys (including Numeric Keys, Scrolling key, Esc, Enter and
Pwr keys).
The TU operates with four 1.5 Volt AA Alkaline batteries.
4
Getting started
WARNING: Do not operate TU with rechargeable batteries.
Terminal Unit Master Key
Remote Controlled Unit
c
d
e
g
Front
:
c Squib Contacts
d Foldable Antenna
e Green LED
f Red LED
g Test Key
h Power Key
Back
:
z Battery Bay with transparent cover
z Battery (9 Volt alkaline battery - Not Included)
z Transparent foldable leg
Remote Controlled Unit- 16
The Remote Controlled Unit - 16 includes the following elements:
Front Panel with Green LED and Red LED and Test and Power Keys
16 Squib Contacts
Foldable Antenna
Battery Bay with transparent cover
Battery (9 Volt alkaline battery - Not Included)
Transparent foldable leg
BASE UNIT, EXTENSION UNIT and EXTERNAL PTT are detailed in a separate
manual.
f