RAB Lighting YBLED 3 pin PCT, YBLED 5 pin PCT, YBLED LC, YBLED Button PC Installation Instructions Manual

Page 1
YBLED 40W-60W INSTALLATION INSTRUCTIONS
®
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
YBLED Button PC
YBLED 3 pin PCT
YBLED 5 pin PCT
YBLED LC
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture.
LOCATION
Select a location on a structurally sound, at wall or pole. Fixture should be located on wall or pole at least 18” below any overhang or other structural detail. Fixture must not be recessed.
MOUNTING TO WALL
1. Secure the xture to a sturdy wall. Using the mounting arm as a guide, mark the 3 mounting holes. Drill 3/16” pilot holes and use provided Lag Bolts (3) to mount to wooden surface or use appropriate mounting hardware (not supplied) suitable for the mounting surface.
2. Install the 2 bottom Lag Bolts rst. Screw in the Lag Bolts so that there is about 3/8” of space under the head.
3. Place the xture on these 2 bottom Lag Bolts. Install the top Lag Bolt then tighten the other 2 bolts.
4. Loosen screw and remove the Arm Cover.
5. Knock out the appropriate Conduit Knockout on the Arm Cover to route input conduit. Use appropriate conduit connectors as required by code. Connect wires as shown in wiring diagram. Push all wires back into the Housing Arm. Be careful not to pinch wires.
6. Secure the Arm Cover and tighten screw.
7. Apply weatherproof silicone sealant around the edge of the Housing Arm and the wall. This is especially important with an uneven wall surface.
YARM24 MOUNTING
1. Secure the Interlocking Mounting Clamps around the YARM24 using the provided truss screws, locknuts and
hex-nuts.
2. Mount the YARM24 to a sturdy wall. Using the YARM24 mounting plate as a guide, mark the 4 mounting holes. Drill 3/16” pilot holes and use provided Lag Bolts (4) to mount to wooden surface or use appropriate mounting hardware (not supplied) suitable for the mounting surface.
3. Remove the Arm Cover by loosening the screw. Remove the Clamp by loosening the 2 screws on the Clamp.
4. Knock out the arm-entry knockout on the Arm Cover. Secure the YARM24 and the Clamp in the Housing Arm and tighten the clamp screws.
5. Knot wires in YARM24 for strain relief and feed wires from the YARM24 into the Housing Arm. Make the necessary wiring connections in the Housing Arm. Connect wires as shown in wiring diagram. Push all wires back into the Housing Arm. Be careful not to pinch wires.
6. Secure Arm Cover and tighten the screw.
Housing Arm
Lag Bolts (3)
Conduit Knockout
Arm Cover
Housing Arm
Arm Cover
Clamp
YARM24
Interlocking Mounting Clamps
Lag Bolts (4)
Page 2
YBLED 40W-60W INSTALLATION INSTRUCTIONS
®
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
WIRING
Universal voltage driver permits operation at 120V to 277VAC, 50 - 60 Hz.
1. Connect the bare copper Ground wire from xture to supply ground.
2. Connect the BLACK xture lead to the LINE supply lead.
3. Connect the WHITE xture lead to the COMMON supply lead.
ACCESSORIES
24” Yardblaster Arm: YARM24
TROUBLESHOOTING
1. Check that the line voltage at the xture is correct. Refer to wiring directions.
2. Be sure xture is grounded properly.
3. Be sure the photocell is functioning properly?
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to touch. Do not clean or maintain while xture is energized.
1. Clean polycarbonate refractor with non-abrasive cleaning solution.
2. Do not open the xture to clean the LED. Do not touch the LED.
Pat: D 713019
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.