WPLEDTM 78W WALL MOUNT INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fi xtures.
Our goal is to design the best quality
products to get the job done right. We’d like
to hear your comments. Call the Marketing
Department at 888-RAB-1000, or email:
marketing@rabweb.com
IMPORTANT
READ CAREFULL Y BEFORE INST ALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper
grounding is required for safety. This product must be installed in accordance with the applicable installation code by a
person familiar with the construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fi xture. No user servicable parts
inside.
MOUNTING ARM ON FIXTURE
1. Remove the Arm Cover from the Arm.
2. Feed wires from Fixture through Gasket into Arm.
Fixture
Gasket
Arm
3. Line up Arm and Fixture. Place fl at washers, lock
washers and nuts on the 3/8-16” bolts inside the Arm
and tighten securely to housing.
4. Make sure the Gasket is secure between Arm and
Fixture.
MOUNTING FIXTURE ON WALL
1. Separate Wall Mount Cover and Wall Mount Box.
2. Orient box so that “TOP” is on top.
3. Secure Wall Mount Box to a sturdy wall. Use
appropriate mounting hardware such as lag bolts and
anchors with washers suitable for the mounting surface. Use weatherproof silicone sealant between wall
and Wall Mount Box.
4. Feed supply wires through Wall Mount Box, Gasket,
and Wall Mount Cover.
5. Check that Gasket between Wall Mount Box and
Wall Mount Cover is secure and screw the cover on
box using four screws.
6. Line up Arm and Wall Mount Cover. Place fl at wash-
ers, lock washers and 3/8-16 bolts from wall bracket
(do not use long bolts provided with Arm), inside the
Arm and tighten securely.
7. Feed wires through the Arm Gasket into Arm. Make
necessary connections in the Arm.
8. Replace the Arm Cover. Be sure Gasket on Arm
Cover is in place.
Arm Cover
Arm
Gasket
Plugs
Plugs
Arm Gasket
3/8-16 bolts
Screws
Wall Mount
Cover
Tether
3/8” bolts
Gasket
Wall Mount Box
Plugs (4)
9. Tighten Close Up Plugs and apply weatherproof
silicone sealant to all unused conduit entry points.
Also use sealant between the wall and Wall
Mount Box.
Page 1

®
WPLEDTM 78W WALL MOUNT INSTALLATION INSTRUCTIONS
WALL MOUNT BOX DETAILS
4.57”
Key Hole Slot
2.4”
1.09”
3.0”
Wall Feed
.79”
Hardware
(not supplied)
Conduit Feed
TROUBLESHOOTING
1. Check that the line voltage at fi xture is correct. Refer
to wiring directions.
2. Is the fi xture grounded properly?
3. Is the photocell functioning properly (if used)?
WIRING
Universal voltage driver permits operation at 120 to
277VAC, 50 or 60Hz.
1. Connect the black fi xture lead to the (+) LINE
supply lead.
2. Connect the white fi xture lead to the (-) COMMON
supply lead.
3. Connect the bare copper Ground wire from fi xture to
supply ground.
-*/& #-"$,
$0..0/ 8)*5&
-*()5
'*9563&
(306/% (306/%
CLEANING & MAINTENANCE
CAUTION: Be sure fi xture temperature is cool
enough to touch. Do not clean or maintain while
fi xture is energized.
1. Clean glass lens with non-abrasive glass cleaning
solution.
2. Do not open fi xture to clean the LED. Do not touch
the LED.
RAB fi xture designs are protected under
U.S. and International Intellectual Property laws.
Patent pending.
Page 2

®
WPLEDTM 78W WALL MOUNT INSTALLATION INSTRUCTIONS
WPLED2T78 Cool
WPLED3T78 Cool WPLED4T78 Cool
WPLED2T78 Neutral
WPLED3T78 Neutral WPLED4T78 Neutral
WPLED78 IN 1011
Page 3