RAB Lighting WPLED10, WPLED10S Installation Instructions Manual

Page 1
10W LED WALLPACK INSTALLATION INSTRUCTIONS
xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com
WPLED10
Junction Box
WPLED10S Surface Mount
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable
parts inside.
JUNCTION bOx MOUNT fOR CONDUIT
For use on retrot applications that make conduit necessary.
Loosen and remove (3) Lens Screws. Remove
1. Door.
Loosen and remove (2) Housing Screws. Remove
2. Housing from Back Box. Keep Gasket intact for re-assembly.
Secure Back Box to the mounting surface using
3. hardware appropriate for that mounting surface.
Wire the xture using UL approved wire connectors
4. and according to NEC and local codes. Apply sealant to all unused conduit entry points.
Place Gasket between Back Box and Housing.
5. Re-mount Housing to Back Box. Check Gasket seal all around the Back Box.
Re-mount Door to Housing. Tighten (3) Lens
6. Screws. Check Door gasket seal.
SURfACE MOUNT fOR RECESSED bOx
For use with recessed junction box and wiring.
Use supplied crossbar. Mount Crossbar to recessed
1. junction box with (2) screws.
Place Gasket on back of the xture. Gasket should
2. create seal against mounting surface.
Wire xture to supply wires in recessed box according
3. to wiring section.
Use 1/4 x 20 stainless steel Mounting Screw to
4. attach xture to Crossbar. Tighten Mounting Screw.
Cover screw with Cap, provided.
5.
Fixture can be mounted upside down in dry and damp
6. locations only.
Crossbar
Gasket
7.
Back Box
Fixture can be mounted upside down in dry and damp locations only.
Gasket
Lens Screws
Housing
Housing
Screws
Door
Cap
Mounting
Screw
Recessed
Junction Box
Page 2
10W LED WALLPACK INSTALLATION INSTRUCTIONS
-*()5
'*9563&
-*/& #-"$,
$0..0/ 8)*5&
(306/%
(306/%
JUNCTION bOx
The Junction box has (4) conduit entry points
1. on the center of each side and (1) in the center back.
Mounting points are dimensioned below.
2.
4 3/4”
1 1/8”
2 3/16”
3 1/2”
WIRING
All units are factory wired for 120V.
Connect the black xture lead to the (+) LINE
1. supply lead.
1 1/8”
TROUbLESHOOTING
Check that the line voltage at xture is correct.
1.
Refer to wiring directions.
Is the xture is grounded properly?
2.
Is the photocell is functioning properly (if used)?
3.
Lighting Facts - 5200K
Connect the white xture lead to the (-) COMMON
2. supply lead.
Connect the bare copper Ground wire from xture to
3. supply ground.
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to touch. Do not clean or maintain while xture is energized.
Clean glass lens with non-abrasive glass cleaning
1. solution.
Patent pending
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Lighting Facts - 2800K