RAB Lighting VX Series, VXBR Series Installation Instructions Manual

Page 1
VX/ VXBR CFL INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture.
MOUNTING
Tether
Fixture should be located on wall or ceiling and not be recessed. Use the Housing Template to match the recessed or surface mount Junction Box (not supplied) or use the Housing to make electrical connections. Fixture cannot be mounted upside down in wet locations. For more secure installation, lag bolt ballast box to mounting surface.
Cable
Housing Screws
1. Loosen Housing Screws from Front of Housing.
2. Prepare Back of Housing for use by knocking out the
appropriate mounting holes.
3. Seal all gaps between ceiling and xture with
weatherproof silicone sealant. (Be sure to use the Gasket supplied.)
4. Fixture may be wired through back conduit entrance or
either side conduit entrance for surface mounting.
5. Connect wires as shown in wiring section. The Back of
Housing has a Tether Cable and the Front of Housing has a Loop for hanging the xture during wiring.
6. Reattach the Front & Back Housing. Be sure the original
Gasket seals properly. Tighten Housing Screws.
7. Install the lamp, globe and guard.
8. Seal all holes, plugs and conduit entrances with
weatherproof silicone sealant.
Loop for Tether
Back of Housing
Housing Template
Junction Box on Wall
Gasket
Front of Housing
Back of Housing
Page 2
VX/ VXBR CFL INSTALLATION INSTRUCTIONS
Easy Installation & Product Help
©2012 RAB LIGHTING Inc.
No
LIGHT
FIXTURE
(+)LINE BLACK
(-)COMMON WHITE
GROUND GROUND
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
LAMP INSTALLATION
CAUTION: Prior to installing, check that the lamp is the correct wattage. Observe lamp manufacturer’s recommendations on lamp operation, ballast type and burning positions.
1. Disconnect power. Make sure xture and lamp are cool
enough to touch.
2. Open xture by unscrewing guard and globe from
xture.
3. Fully insert the lamp into the socket.
4. Replace globe and guard.
5. Tighten screws.
WIRING
Use supply wire rated for 90°C. The units are wired for 120V. Units built for a specic voltage are factory-wired for the requested voltage. Make sure the supply voltage is compatible with the unit. Multi tap units may be used with a choice of 120V, 208V, 240V and 277V, provided that proper ballast leads are connected in the eld.
REPL ACEME N T LAMPS AND BALLASTS
RAB Lamp RAB Ballast Wattage Catalog# Catalog#
Compact Fluorescent Lamp
13 LCFL13Q-4P BCFL13-4E 26 LCFL26 BCFL42 32 LCFL32 BCFL42 42 LCFL42 BCFL42
TROUBLESHOOTING
1. Is the proper lamp installed?
2. Make sure the lamp is not defective. Try a lamp known to
be in operating condition.
3. Check that the line voltage at xture is correct. Refer to
wiring directions.
4. Is there voltage at the lamp socket? If there is no voltage,
check all connections.
5. Is the xture grounded properly?
1. Connect the black xture lead to the (+) LINE supply lead.
2. Connect the white xture lead to the (-) COMMON supply
lead.
3. Connect the Ground wire from xture to supply ground.
4. All unused leads must be capped and insulated.
ACCESSORIES
Die Cast Guard: GD100DG
GD200DG
Wire Clamp Flat Bottom: GD100BAR
GD200BAR
Wire Clamp Round Bottom: GD100CL
GD200CL
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to touch. Do not clean or maintain while xture is energized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. As lamps age, light output diminishes. Mass re-lamping
at regular intervals ensures full light output at the highest eciency.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
rthvale, New Jersey 07647 USA
VX/ VXBR CFL-IN 0113
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
Loading...