VXBRLED INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call
the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper
grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable
parts inside.
Housing
Gasket
Housing
Screws (2)
WALL MOUNT
Fixture must be wall mounted. Use recessed or surface
mount junction box (not supplied) or use the Housing as
the junction box. Fixture cannot be mounted upside
down in wet locations!
1. Loosen Housing Screws and open Housing.
2. Prepare back of Housing to use by knocking out
necessary mounting holes.
3. Seal all gaps between wall and xture with
weatherproof silicone sealant.
4. Fixture may be wired through back conduit entrance
or side conduit entrance for surface mounting.
5. Connect wires as shown in wiring section.
6. Close Housing. Tighten screws and check Housing
Gasket seal.
7. Seal all holes, plugs and conduit entrances with
weatherproof silicone sealant.
Housing
Pat. Pending
Note: These instructions do not cover all details or variations
in equipment nor do they provide for every possible situation
during installation, operation or maintenance.

VXBRLED INSTALLATION INSTRUCTIONS
WIRING
Universal voltage driver permits operation at 120V thru
277V, 50 or 60 Hz.
1. Connect the black xture lead to the (+) LINE
supply lead.
2. Connect the white xture lead to the (-) COMMON
supply lead.
3. Connect the GROUND wire from xture to
supply ground.
(+)LINE BLACK
(-)COMMON WHITE
GROUND GROUND
LIGHT
FIXTURE
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool
enough to touch. Do not clean or maintain while
xture is energized.
1. Clean glass lens & xture with non-abrasive glass
cleaning solution.
2. Do not open xture to clean the LED. Do not touch
the LED.
TROUBLESHOOTING
1. Check that the line voltage at xture is correct.
2. Is there voltage at the lamp xture wires? If there is
no voltage, check all connections.
3. Is the xture is grounded properly?
VXBRLED13DG-IN-0211