LFLED8 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WALL MOUNTING
Mount to a weatherproof junction box and cover plate (not supplied) as shown. To ensure weatherproof seal, apply weatherproof silicone sealant around the edge of the wall cover plate or surface box. This is especially important with an uneven wall surface.
1. Seal arm thread using Teon tape or silicone sealant.
2. Thread xture into Cover Plate(not supplied).
3. Connect wires as shown in the wiring diagram.
4. Attach cover plate to Junction Box (not supplied).
5. Aim oodlight in the direction desired and tighten locknut and Arm Screw.
Arm Screw
GROUND MOUNTING
Mount to a Mighty Post (RAB Cat# MP19) as shown.
1. Thread xture into Mighty Post Cap.
2. Connect wires as shown in the wiring diagram and place inside the Mighty Post.
3. Place Mighty Post Cap on the Mighty Post.
4. Aim oodlight in the direction desired and tighten locknut and Arm Screw.
Arm Screw
Mighty Post Cap
Junction Box (not supplied)
Cover Plate (not supplied)
Mighty Post
Page 2
LFLED8 INSTALLATION INSTRUCTIONS
Easy Installation & Product Help
©2014 RAB LIGHTING Inc.
No
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
WIRING
Universal voltage driver permits operation at 120V thru 240V, 50 or 60 Hz.
1. Connect the black xture lead to the (+) LINE supply lead.
2. Connect the white xture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from xture to supply ground.
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to touch. Do not clean or maintain while xture is energized.
1. Clean glass lens & xture with non-abrasive glass cleaning solution.
2. Do not open xture to clean the LED. Do not touch the LED.
TROUBLESHOOTING
1. Check that the line voltage at xture is correct. Refer to wiring directions.
2. Is the xture grounded properly?
3. Keep leaves and debris out of hood.
ACCESSORIES
Reector door lens kit can be ordered separately
LNSLFLED8 15° spot reector, door, lens kit for LFLED8 LSLFLED8 20° spot reector, door, lens kit for LFLED8
Patent - US: pat. 676,190; CN: ZL201230408896.9; CA: D RAB Lighting, Inc MX: 39011; TW: pat. pending Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance.
rthvale, New Jersey 07647 USA
LFLED8-IN-0814
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
Loading...