ALED POST TOP INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
FIXTURE ASSEMBLY
1. Feed the (3) Housing wires through one of the three Rods.
2. Clip the (3) Rods onto the Housing. Be sure the Housing clips are properly engaged onto the Rods.
3. Feed Fixture Wires through the Tenon Pole Adaptor.
4. Slide Tenon Pole Adaptor on three Rods. Be sure the notches face the inside of the Tenon Pole Adaptor.
5. Tighten the (3) Set Screws at the Tenon Pole Adaptor to secure Rods.
POLE MOUNTING
1. Make the wiring connections with UL approved connectors knot the wires for strain relief.
2. Slip Tenon Pole Adaptor over 2 3/8” diameter tenon and secure with the set screws on the side of Tenon Adaptor.
Set Screw (to secure Tenon)
Tenon Pole Adaptor
Set Screw (to secure Rods)
Housing­Wires
Rods (3)
Housing Wires
Housing
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance.
Page 2
R
LIGHT
FIXTURE
(+)LINE BLACK
(-)COMMON WHITE
GROUND GROUND
Call our experts 888 RAB-1000
Northvale, New Jersey 07647 USA
Visit our website for product info
Answered promptly sales@rabweb.com
ALED POST TOP INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
WIRING
Universal voltage driver permits operation at 120 to 277VAC, 50 or 60Hz.
1. Connect the black xture lead to the (+)
LINE supply lead.
2. Connect the white xture lead to the (-)
COMMON supply lead.
3. Connect the bare copper Ground wire from xture to
supply ground.
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to touch. Do not clean or maintain while xture is ener­gized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open xture to clean the LED. Do not touch the LED.
010V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. 0-10V control wires must be rated for 300V minimum. For 0-10V Dimming, follow the wiring directions as in g. 2.
1. Connect the black xture lead to the (+) LINE supply lead.
2. Connect the white xture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from xture to supply ground. Do NOT connect the GROUND of the dimming xture to the output.
4. Connect the purple xture lead to the (V+) DIM lead.
5. Connect the gray xture lead to the (V-) DIM lead.
6. Cap the yellow xture lead. Do NOT connect.
Fig. 2
TROUBLESHOOTING
1. Check that the line voltage at xture is correct. Refer to wiring directions.
2. Is the xture grounded properly?
ALED5T52 ALED5T78
©2012 RAB LIGHTING Inc.
ALED5T78 IN-0514