RAB Lighting ALED POST TOP Installation Instructions Manual

Page 1
R
ALED POST TOP INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
FIXTURE ASSEMBLY
1. Feed the (3) Housing wires through one of the three Rods.
2. Clip the (3) Rods onto the Housing. Be sure the Housing clips are properly engaged onto the Rods.
3. Feed Fixture Wires through the Tenon Pole Adaptor.
4. Slide Tenon Pole Adaptor on three Rods. Be sure the notches face the inside of the Tenon Pole Adaptor.
5. Tighten the (3) Set Screws at the Tenon Pole Adaptor to secure Rods.
6. For 3” tenon use shorter tenon Set Screw 5/8” and for 2-3/8” tenon use ALED sleeve and hardware to secure the
Housing to tenon.
POLE MOUNTING
1. Make the wiring connections with UL approved connectors knot the wires for strain relief.
Tenon Pole Adaptor
ALED sleeve
Set Screw 5/8” (to secure 3”Tenon)
Set Screw (to secure Rods)
Rods (3)
Housing
2. Tenon Pole Adaptor can t tenon with 3” or 2 /” diameter. Use ALED Sleeve if necessary for better t.
Page 2
R
LIGHT
FIXTURE
(+)LINE BLACK
(-)COMMON WHITE
GROUND GROUND
Easy Answers
rabweb.com
Visit our we bsite for produc t info
Tech Help Line
Call our ex perts - 888 722-1000
e-mail
Answered promptly - sales@rabweb.com
Free Lighting Layouts
Answered o nline or by reques t
© 2017 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
ALED POST TOP INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz, except xtures factory ordered with 480V twistlock photocell (/PCT4). Units ordered with (/480) sux are 480V.
1. Connect the black xture lead to the (+) LINE supply lead.
2. Connect the white xture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from xture to supply ground.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. 0-10V control wires must be rated for 300V minimum. For 0-10V Dimming, follow the wiring directions as shown below.
1. Connect the black xture lead to the (+) LINE supply lead.
2. Connect the white xture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from xture to supply ground. Do NOT connect the GROUND of the dimming xture to the output.
4. Connect the purple xture lead to the (V+) DIM lead.
5. Connect the gray xture lead to the (V-) DIM lead.
6. Cap the yellow xture lead. Do NOT connect.
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to touch. Do not clean or maintain while xture is energized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open xture to clean the LED. Do not touch the LED.
TROUBLESHOOTING
1. Check that the line voltage at xture is correct. Refer to
wiring directions.
2. Is the xture grounded properly?
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance.
ALED5T IN-0517