General Safety Information
About Your BioGS Air Purifier
• Please read all tips and warnings before using your Rabbit Air purifier.
• Use only as directed by the Owner’s Manual.
• Please observe extreme caution when using the air purifier in close proximity
to children.
• Rabbit Air purifiers are for indoor use only.
• The Rabbit Air purifier is not intended for use in bathrooms, laundry areas, or other damp indoor environments. Keep the Rabbit Air purifier away from water
at all times.
• Do not use the Rabbit Air purifier near fireplaces or in areas where flammable or
combustible products or vapors may be present.
• This appliance has a polarized plug (one blade is wider than the other). To
reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this
safety feature.
• This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure they do not play with the appliance.
• This product complies with the maximum allowable concentration of ozone of
0.050 parts per million by volume (ppmv) in a 24-hour period. The Health
Canada Guideline 2010 recommends that the Maximum exposure limit, based on an averaging time of 8 hours, is 0.020 ppmv or less when tested in a Sealed,
controlled room approximately 30 m³.
Caution: When using electrical appliances, observe the following basic
precautions to reduce the risk of fire, electric shock, and injury:
Meet your brand new BioGS®!
We hope that this stylish bundle of cleanliness is just what
you've been looking for. Be sure to get familiar with this
newest addition to your home, by exploring all of its fea-
tures in the enclosed booklet and on our website.
If you have any questions just give us a call, anytime.
We love to hear from you!
Hello there!
1 2
A childproof feature pauses air purifier operation when
the front panel is removed.
Page 3
Operation Guidelines
Remote Control Tips
Installation Guidelines
• Do not block the air intake or air outlet.
• Do not use the Rabbit Air purifier on or around hot surfaces.
• Do not use the Rabbit Air purifier in a room where it may come into contact
with steam.
• Do not operate the Rabbit Air purifier on its side.
• Do not install the Rabbit Air purifier in greasy or damp environments.
• Do not use detergent or soap to clean the Rabbit Air purifier.
• Do not operate the Rabbit Air purifier without filters.
• Do not wash and reuse the filters except for the washable Pre-Filter.
• When transporting the Rabbit Air purifier, always hold the handle on
the back of the unit.
• Inverter lighting equipment or electronic light fixtures may interfere
with remote control signals.
• Avoid storing the remote control in direct sunlight. Heat may interfere with remote control signals.
• Avoid putting the Rabbit Air purifier in a place where the air intake or air
outlet could become clogged with dirt.
• Leave at least two feet of space between the air purifier’s intake, outlet,
and the wall.
Electrical Safety Instructions
• The Rabbit Air purifier is designed for use in a 110/120V outlet only.
• Turn off your Rabbit Air purifier before unplugging it from the power outlet.
• Unplug the Rabbit Air purifier from the power outlet when not in use and
before servicing or cleaning the unit.
• To reduce the risk of electric shock, the Rabbit Air purifier has a polarized plug, which means it will fit into a polarized outlet only one way. If the plug does not fit into the outlet, reverse the plug. If it still does not fit, contact qualified
personnel to install the proper outlet. Do not alter the plug in any way.
• To avoid electric shock, do not touch the air purifier or its power plug
with wet hands.
• Keep the electrical cord away from heated surfaces at all times.
• If the cord or plug appears damaged, return the unit immediately to an
authorized service facility for examination and repair.
• Any attempts to repair the Rabbit Air purifier without written permission from Rabbit Air will void the warranty and could cause serious personal injury to the
user and/or result in severe damage to the unit.
• Do not pull, carry, lift, or drag the Rabbit Air purifier by pulling its power cord.
Remove the power plug from its outlet by grasping the plug and pulling gently.
• When the Rabbit Air purifier is plugged into a power outlet, keep all fingers, body parts, hair, jewelry, and loose clothing away from the openings.
The Energy Star label and disclaimer:
The energy efficiency of this ENERGY STAR qualified model is measured based on a
ratio between the model’s CADR for dust and the electrical energy it consumes, or
CADR/Watt.
3 4
Page 4
Meet your BioGS 2.0
Front view
Back view
Top view
Remote holder
Air outlet
Control button / User interface
Remote holder
Handle
Air quality sensor
(Includes odor and
particle sensors)
Power cord
Air intake
Air intake
5 6
Page 5
Remote Control
Power
User Interface Device Control - Section 1
Timer
Fan Speed
Auto Mode
Negative Ion
on/off
Lithium coin battery (3V)
Device Control
(Section 1)
Filter Status
(Section 3)
Device Settings
(Section 2)
The control button light will appear when the BioGS is operating.
Tap this button to power on the unit.
Tap it again to cycle through different fan speeds and auto modes.
Press and hold to power off the unit.
Main Control Button
CR 2025
7 8
Page 6
Device Settings - Section 2
When the unit has been idle for five minutes, the
user interface lights will disappear. To view the
display, tap the control button on the unit or
remote.
When the air purifier is in Auto Mode, the Air Quality
Indicator will continually monitor the odor and particle
levels in the air, the user interface will light up briefly each time the pollution level changes. When the purifier is in a manual speed setting, the interface will not light up.
• Air Quality Indicator
These lights indicate the current manual speed setting. Low fan speed is indicated by a single light.
High fan speed is indicated by five lights. When in Auto Mode, the fan speed will adjust according to the air quality.
• Fan Speed
These lights indicate the level of sensitivity of the air
quality sensor when the unit is in Auto Mode. The fan adjusts its speed according to the air quality.
• Auto Mode
Set the air purifier to turn off after a specific period of time. One light indicates a four-hour timer, two lights indicate an eight-hour timer, three lights
indicate a 12-hour timer.
• Timer
When this light is on, it means the unit is generating
negative ions.
• Negative Ions
These lights indicate the level of air pollution detected.
on/off
Low Medium High
These lights indicate the fan speed of the unit.
Low Medium High
These lights indicate the sensitivity of the air quality sensor.
Low Medium High
These lights indicate how long the timer has been set for.
4 hours 8 hours 12 hours
This light illuminates if the Negative Ion Generator is on.
This feature can be accessed through the main control button.
This feature can be accessed through the remote.
9 10
Page 7
Filter Status - Section 3
The Filter Maintenance and Replacement Light will illuminate
when your air purifier needs attention.
Solid light = It’s time to clean the filters. Flashing light = It’s time to replace the filters.
• Filter Maintenance & Replacement Light
The Filter Life Light is visible only when the front panel has been removed. It indicates how much time has passed since the last
time the filters were replaced. Since the filters should be cleaned every three months, each light represents three months of the filters’ life. Each time a light goes out, the Filter Maintenance and Replacement Light will illuminate to inform you that it's time to clean the filters.
6 LEDs = The filters are new. 1 LED = The filters should be replaced soon.
• Filter Life Light
Press this button briefly to turn off the Filter Maintenance and Replacement Light after each cleaning, the Filter Life
Light will continue to diminish as time passes.
We recommend replacing the filters every 18 months. After you have replaced them, press and hold for 5 seconds to
reset the Filter Life Light.
• Filter Reset Button
11 12
Page 8
Pre-Filter
BioGS HEPA
Filter
Charcoal-Based
Activated Carbon
Filter
Front Panel
Meet the Filters
13 14
Page 9
Let’s begin - Initial setup
The BioGS Air Purifier is designed for residential use only.
To maintain the quality of the filters, they are packaged in plastic. Please
remove the filters from the plastic bags before using the unit.
1. Remove the front panel by lifting from the bottom and pulling up.
2. Pinch the two tabs on top of the Pre-Filter to remove it.
4. Remove the HEPA Filter and discard its plastic wrapping.
3. Pull out the Activated Carbon Filter and discard its plastic wrapping.
6. Reattach the front panel.
5. Return the filters to the filter case in the following
order from back to front: BioGS HEPA Filter
Activated Carbon Filter Pre-Filter
15 16
Page 10
Cleaning the Pre-Filter
• Vacuum method:
1. Remove the front panel from the air purifier.
2. Run a handheld vacuum cleaner with a nozzle or brush attachment on a low power setting along the Pre-Filter to remove visible particles.
If vacuuming does not seem to sufficiently clean your Pre-Filter, please follow the
steps below to wash it.
• Washing method:
1. Remove the Pre-Filter from the unit.
2. Fill the sink with lukewarm water and gently wash the Pre-Filter under the water for two to three minutes or until it is completely clean.
3. Rinse the Pre-Filter with clean tap water.
4. Use a towel to remove any excess water from the Pre-Filter.
5. Allow the Pre-Filter to dry for 12 to 24 hours.
6. When the Pre-Filter is completely dry, place it back into the air purifier.
The Pre-Filter should be cleaned according to the level of pollution in
the air of the room.
Cleaning and Maintenance
1. Open the air quality sensor cover
(on the right side of the unit).
2. Use a damp cotton swab to clean
the lens, dust inlet, and dust outlet, and dry thoroughly.
Cleaning the Air Quality Sensor
Cleaning the Air Intake and Outlet
Cleaning the Front Panel and Unit Surface
1. Remove the front panel from the unit and use a dry cloth or soft brush to
dust off the front and the back of the panel. If necessary, use a damp cloth
to remove stubborn stains and dirty buildup. Avoid commercial cleaning products.
2. Use a clean, dry cloth to wipe the external surfaces of the air purifier.
1. Clean the air intake and outlet with a dry cloth or a soft brush.
If necessary, use a damp cloth.
Avoid commercial cleaning products.
Caution: Be careful not to drop anything
into the unit.
Cleaning the HEPA Filter
Cleaning the Activated Carbon Filter
1. Run a handheld vacuum cleaner on
low power setting, or a soft brush,
along the HEPA Filter to remove visible particles.
1. Run a handheld vacuum cleaner with a nozzle or brush attachment on low power setting along the Activated Carbon Filter to remove visible particles.
• Vacuum method:
• Vacuum method:
Clean the air quality sensor
every six months or as needed.
(Includes particle and odor sensors)
17 18
dust outlet
dust inlet
Page 11
Replacing the BioGS HEPA Filter
Discard the old Activated Carbon Filter. This filter cannot be reused.
Always unplug the unit before cleaning/replacing the filters.
The lifespan of the air purifier’s filters will vary, based on the amount of
pollutants in your home.
Pre-Filter
Replacing the Filters
The Pre-Filter is a permanent filter and
does not need to be replaced.
1. Pinch the two tabs on top of the Pre-Filter to remove it.
2. Put the Pre-Filter aside while
replacing the other filters.
1. Remove and discard the old HEPA Filter.
2. Remove the new filter from its plastic wrapping.
3. Place the new HEPA Filter in the BioGS unit.
Every 18 months
1. Pull out the old Activated Carbon Filter and discard.
2. Remove the new Activated Carbon Filter from its plastic wrapping and place in the BioGS unit.
Washable filter
Every 18 months
Replacing the Activated Carbon Filter
Do NOT discard the Pre-Filter. It is designed to be cleaned and reused.
Discard the old HEPA Filter. This filter cannot be reused.
Filter Cleaning and Replacement Schedule*
Filters Cleaning
Pre-Filter
BioGS HEPA
Charcoal-Based Activated Carbon
Washable
18 Months
18 Months
*Based on 24/7 operation
Every month
Every 3 months
Every 3 months
Filter Life
The lifespan of the filters is estimated based on normal residential use.
19 20
Page 12
Warranty
Register online at www.rabbitair.com/warranty
• Product Protection
By registering your product and purchase information, we can confirm the date of purchase to secure your warranty. This confirmation serves as security in the event that your original proof of purchase is lost, or in case your unit needs any servicing
in the future.
• Proof of Ownership
Your model number, serial number, and other information will be kept in our files.
Please complete and return this registration within 90 days from purchase in order to receive our 5-year limited warranty.
There are no express warranties except as listed above.
THE WARRANTOR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY, AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE APPLICABLE WARRANTY PERIOD SET FORTH ABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state. If a problem with the
product develops during the warranty period, we will repair or replace it without charge to you. A shipping fee may apply. To obtain service under warranty, please
contact Rabbit Air at 1-888-866-8862 or by e-mail at CustomerService@rabbitair.com
Limited Warranty
Limits and Exclusions
Rabbit Air warrants that your air purifier (“Product”) will be free from defects in material or workmanship for a period of five (5) years from the date of purchase. To activate the warranty, please complete the warranty registration form online at www.rabbi­tair.com/warranty within 90 days of your air purifier purchase. To ensure product performance, the filters should be replaced with authentic Rabbit Air replacement filters as recommended in this manual ('Limited Warranty'). Within the first 90 days of purchase, Rabbit Air will replace the defective unit at no additional cost and reimburse any shipping charges. After 90 days, Rabbit Air's obligation and liability under this
limited warranty is limited to repairing or replacing (at our sole discretion) the defective
product. The limited warranty does not cover replacement filters. In the event of product malfunction or failure, please contact Rabbit Air to obtain a return authoriza-
tion number and the address of the service center. The return authorization number must be clearly written on the outside of the shipping box or the shipment may be
refused. This warranty extends only to the original purchasers who acquire new product from Rabbit Air, its subsidiaries, or its authorized resellers.
Rabbit Air will have no warranty obligation with respect to the following products (“Ineligible Products”): (i) Products that have no defects in materials or workmanship; (ii) Products with defects that are not reproducible by Rabbit Air; (iii) Products marked as
“sample” or sold “AS IS; or (iv) Products that have been subject to: (a) any modifications, alterations, repair, or servicing by any party other than Rabbit Air or Rabbit Air’s autho­rized representatives, (b) handling, storage, installation, testing, or use not in accor­dance with the applicable Documentation, (c) abuse, negligence, neglect, accidents, abuse or misuse, (d) any breakdowns, fluctuations, or interruptions in electric power or connected to improper power supply, or (e) any Acts of God, including fire, flood, tornado, earthquake, hurricane, excessive snow, lightning, riot, insurrection, act of war,
or other disaster.
Register your air purifier online now for:
The Rabbit Air five-year warranty is a statement of
our confidence in the quality of our products and
an assurance that we stand behind that quality 100
percent of the time. Labor is included in our
warranty; when warranty work is
performed, Rabbit Air pays the bill.
21 22