ALEDTM POLE MOUNT INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your
comments. Call the us at 888-RAB-1000, or email: marketing@rabweb.c om
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper
grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable
parts inside.
ALED10, ALED13
MOUNT TO POLE
For use with standard RAB pole drilling. See drawing
below
Mount xture to Pole:
1. Place Adaptor Gasket between the xture and drilled
Pole as shown. Line up center hole with center hole
in the pole drilling pattern.
2. Place 3/8-16 bolt from the Adaptor thru the top hole
of the Gasket to the Pole. Use nut, lockwasher and
washer and tighten inside the pole.
3. Make the necessary wiring connections and knot the
wires for strain relief.
4. Install the Pole Cap.
Nut, Lockwasher &
Washer
Pole Cap
ALED20, ALED26
MOUNT TO POLE
For use with standard RAB pole drilling. See drawing
below
Mount xture to Pole:
1. Place Adaptor Gasket between the xture and drilled
Pole as shown. Line up center hole with center hole
in the pole drilling pattern.
2. Place 3/8-16 bolt from the Adaptor thru the top hole
of the Gasket to the Pole. Use nut, lockwasher and
washer and tighten inside the pole.
3. Make the necessary wiring connections and knot the
wires for strain relief.
4. Install the Pole Cap.
Nut, Lockwasher &
Washer
Pole Cap
Pole
Adaptor Gasket
Pole
Adaptor Gasket

ALEDTM POLE MOUNT INSTRUCTIONS
ROUND POLE ADAPTOR
ACCESSORY
For use with standard RAB pole drilling.
1. Drill round pole using the dimesions shown below in the Pole Drilling Detail.
2. Trim Adaptor Gasket supplied with ALED.
3. Fixture Bolt may not be long enough as originally supplied with ALED. A longer Fixture Bolt is supplied with the RPA
LED kits.
4. Changing Fixture Bolt (if necessary):
a. Open the xture door
b. Remove ALED Adaptor bracket from xture
c. Change Fixture Bolt and re-assemble
5. Place Round Pole Adaptor and RPA Gasket between the xture and drilled Pole as shown. Line up top holes of the
Gaskets and Round Pole Adaptor with top hole in the pole drilling pattern.
6. Place 3/8-16 Fixture Bolt from the ALED thru the top hole of the RPA and Gaskets to the Round Pole. Use nut,
lockwasher and washer and tighten inside the pole.
7. Feed wires through larger bottom hole. Make the necessary wiring connections and knot the wires for strain relief.
8. Install the pole cap.
Round Pole
Adaptor
Fixture Bolt
Adaptor Gasket
(trimmed)
RPA Gasket
Round Pole
(not supplied)
ALED-IN-0311 9524-0

ALEDTM POLE MOUNT INSTRUCTIONS
Pole Drilling Detail
For non-RAB poles use these dimensions to drill the pole. This template is not to scale. Please use measurements
shown. For RPA and ALED mounting bottom hole is not necessary.
ALED-IN-0311 9524-0