QwikClean B2278209 User Manual

NOTICE: This PDF includes a separate SDS representing each
of the component parts of a 2-Part Kit. Each SDS includes 4 sequential pages of pertinent content.
QwikSeal™ AC/R Leak Sealant with Drying Agent Is a 2-Part Kit involving separate 0.5 oz. bottles (labeled Part A and
Part B respectively). Part A – Drying Agent
(actual PDF combined document pages 2-5) Part B – Leak Sealant
(actual PDF combined document pages 6-9)
200 Yellow Place  Rockledge, FL 32955
REVISION DATE: 02/24/2017

SECTION 1 - PRODUCT & COMPANY IDENTIFICATION

SECTION 2 - HAZARDS IDENTIFICATION

SECTION 3 - PRODUCT COMPOSITION INFORMATION

SECTION 4 - EMERGENCY & FIRST-AID PROCEDURES

PH: (321) 631-3550 FAX: (321) 631-3552
E-mail: info@mainstream-engr.com

S A F E T Y D A T A S H E E T

P264 Wash exposed skin thoroughly after handling. P280 Wear protective gloves/protective clothing/eye
protection/face protection.
PRODUCT NAME: QwikSeal® Part A USE: Drying agent for HVAC/R Systems DESCRIPTION: Clear liquid, characteristic odor
MANUFACTURER: Mainstream Engineering Corporation
200 Yellow Place Rockledge, Florida 32955
INFORMATION TELEPHONE: 321-631-3550 EMERGENCY TELEPHONE: 800-424-9300
GHS CLASSIFICATION IN ACCORDANCE WITH 29 CFR 1910
(OSHA HCS): Flammable liquids (Category 3); Skin
sensitization (Category 1B); Eye irritation (Category 2B); Reproductive toxicity (Category 2)
HAZARD STATEMENT(S):
H226 Flammable liquid and vapor H320 Causes eye irritation H361 Suspected of damaging fertility or unborn child
PICTOGRAM(S):
SIGNAL WORD: Warning
PRECAUTIONARY STATEMENT(S):
P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have
been read and understood.
P210 Keep away from heat/sparks/open flames/hot
surfaces. - No smoking. P233 Keep container tightly closed. P242 Use only non-sparking tools. P243 Take precautionary measures against static
discharge. P261 Avoid breathing dust, fumes, gas, mist, vapors,
and/or spray.
P303 + P361 + P353 IF ON SKIN (or hair): Remove immediately all
contaminated clothing. Rinse skin with water. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several
minutes. Remove contact lenses, if present and
easy to do. Continue rinsing. P308 + P313 If exposed or concerned: Get medical advice. P337 + P313 If eye irritation persists: Get medical advice. P370 + P378 In case of fire: Use carbon dioxide, dry sand, dry
chemical or alcohol-resistant foam for extinction. P403 + P235 Store in a well-ventilated place. Keep cool. P501 Dispose of contents/ container to an approved
waste disposal plant.
HAZARDS NOT OTHERWISE CLASSIFIED BY GHS: none
COMPONENT CAS # AMOUNT
2,2-Dimethoxypropane 77-76-9 40-80% * 20-60%
* TRADE SECRET – PATENT PENDING PROPRIETARY FORMULA. Specific chemical identities are withheld as a trade secret under the provisions of OSHA hazard communication standard 29 CFR 1910.1200
EYE: Flush eyes gently with water for at least 15 minutes
while holding eyelids apart; seek immediate medical attention.
SKIN: Remove contaminated clothing. Wash exposed area
with soap and water. If symptoms persist, seek medical attention.
INGESTION: Seek medical attention. If individual is drowsy
or unconscious, do not give anything by mouth; place individual on the left side with the head down. Contact a physician, medical facility, or poison control center for
Page 1 of 4
200 Yellow Place  Rockledge, FL 32955

SECTION 5 – FIRE-FIGHTING MEASURES

SECTION 6 – ACCIDENTAL RELEASE MEASURES

SECTION 7 – HANDLING AND STORAGE

SECTION 8 – EXPOSURE CONTROLS AND PERSONAL
PROTECTION MEASURES

PH: (321) 631-3550 FAX: (321) 631-3552
E-mail: info@mainstream-engr.com
advice about whether to induce vomiting. If possible, do not leave individual unattended.
INHALATION: If symptoms develop, immediately move
individual away from exposure and into fresh air. Seek immediate medical attention. Keep person warm and quiet. If person is not breathing, begin artificial respiration. If breathing is difficult, administer oxygen.
EXTINGUISHING MEDIA: Use dry chemical, carbon dioxide,
or foam extinguishing materials.
HAZARDOUS DECOMPOSITION PRODUCTS: Carbon
dioxide, carbon monoxide, silicon oxides.
UNUSUAL FIRE AND EXPLOSION HAZARDS: Material is
volatile and readily gives off vapors which may travel along the ground or be moved by ventilation and ignited by pilot lights, flames, sparks, heaters, smoking, electric motors, static discharge or other ignition sources at locations near the material handling point.
SPECIAL FIRE FIGHTING PROCEDURES: Wear self-
contained breathing apparatus in positive pressure mode with confined facepiece.
PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND
EMERGENCY PROCEDURES: Use personal protective
equipment outlined in section 8 for normal handling of this material. Remove all possible sources of ignition from the vicinity. Ensure adequate ventilation and minimize exposure to vapors. Evacuate personnel to safe areas. For personal protection see section 8.
ENVIRONMENTAL PRECAUTIONS: Prevent release to the
environment if possible. Do not flush product into drains or sewer lines.
MATERIALS FOR CONTAINMENT AND CLEAN-UP: Use a
nonflammable absorbent material for clean-up. Place in container for disposal according to local regulations.
REFERENCE TO OTHER SECTIONS: For additional disposal
directions and reporting requirements, please refer to Section 13.
PRECAUTIONS FOR SAFE HANDLING: Keep container
closed when not in use. Use good personal hygiene practices in accordance with this material. Avoid getting the product in eyes or on skin. Remove contaminated clothing and clean before re-use. Wash hands before eating or drinking.
Make sure there is adequate ventilation in order to minimize exposure to possible vapors.
Keep away from heat and flame. Keep operating temperatures of equipment below ignition temperatures at all times. Use non-sparking tools.
Please wear appropriate personal protective equipment for handling of this product as outlined in Section 8.
STORAGE: Store in a cool, dry location. Keep container
tightly closed. Do not store near heat, flame, strong
oxidants. Maintain adequate ventilation.
SPECIAL STORAGE CONSIDERATIONS: Even when emptied,
the containers may retain product residues (vapor and/or liquid), and this may pose a static ignition hazard.
Sudden release of hot organic vapors or mists from process equipment operating at elevated temperature and pressure, or sudden ingress of air into vacuum equipment, may result in ignition without presence of obvious ignition sources. Any use of this product in elevated temperature processes should be thoroughly evaluated to establish and maintain safe operating conditions.
EXPOSURE LIMITS: No exposure limits have been
established for this material.
ENGINEERING CONTROLS: In enclosed environments,
exhaust ventilation by explosion-proof mechanical means may be necessary to control air contaminants below specified exposure limits. Handle product in accordance with good industrial hygiene and safety practice.
PERSONAL PROTECTIVE EQUIPMENT: Please wear
appropriate person protective equipment for handling of this product as indicated below.
EYE PROTECTION: Chemical splash goggles are advised. SKIN PROTECTION: Use gloves of an appropriate material
(latex, nitrile or PVC gloves) to minimize exposure.
RESPIRATORY PROTECTION: Engineering or administrative
controls should be implemented to reduce exposure during normal handling of this product. If the workplace
Page 2 of 4