INSTRUCTIONS FOR THE NU-MAtic
Nu - 10FS
8/18/06 - Nu-Matic10FS.cdr
Set up For
Place your VCA6 connector under the bag
wherever it is most convenient for you.
VAKuum Bag
or
Frame Press
T wo very important items to note about the NU-Matic. The air pressure must be kept between 85 and 100 psi. Having the pressure exceed 100 psi
could cause damage to some components.
The second item is to provide clean air. If you have filtered air and are using quick disconnects, make sure that the female connector is clean.
Having filtered air will not do you any good if you pick up the female connector off the floor and it has sawdust and chips in it. These will blow
into the components and possibly cause a problem.
The NU-Matic has a three position toggle switch in the top center of the box. This allows you to turn the unit on to run continuously or to be
regulated when used with a V AKuum Bag or frame Press.
Valve in rear of box.
V acuum Lines
Veneering
Clear
Compressed Air
See Notes Below
Blue
Set up For
Klamping
Clear
Blue
The hand valve in the rear is to be closed when doing veneering. When working with vacuum jigs and fixtures, turn the valve on
(points to left) and turn the toggle switch to VAK Klamp, then step on the TOP of the foot pedal. This will give vacuum to the jig,
to release the part from the jig, step on the BOTTOM of the foot pedal.
Toggle SWITCH
Make sure that when you are clamping you have the Toggle switch on “VAK-KLAMP.” Never have the switch on “VAK-BAG”
when you are clamping. Only use “VAK-BAG” when you are veneering.
1. Attach your air line to the right side fitting (1/4 NPT). If the unit is new and fails to reach vacuum level and shut off, it’s probably
due to lack of compressed air. The unit will also flutter on and off rapidly if it does not receive sufficient compressed air .
2. Flip the toggle switch to the V AK Bag position. The unit should go to V AKuum level (24 to 25“ Hg) and shut off. If the unit goes up
to V AKuum level and shuts of f, you can connect the hose to the bag or frame press.
The air pressure gauge must be between 85 and 100 psi when the unit is running. Not enough pressure and the unit will not shut off.
The VAKuum sensor is just below the toggle switch. T urning it counter clockwise will cause the unit to shut of f at a lower vacuum
level. Do not adjust this unless you want less pressure (weak form) or you do not have enough air to get to vacuum level.
The Pneumatic Foot Switch is connected to the front of the unit. On the box the Clear color hose connects to the Chrome color
nipple (bottom barb on foot pedal) and the Blue ( or green) color hose connects to the brass nipple (upper left on foot pedal). The foot
switch must be connected for the unit to operate. If the unit must be run in the veneering position without the foot switch the chrome
nipple must be blocked. A blocked hose (gizmo) is provided for this purpose.
CALL 1-800-547-5484 TODAY!
Or visit our site at www.qualityvak.com
Quality VAKuum Products, Inc.
74 Apsley St. - Hudson, MA 01749
Tel: 978-562-4680 - Fax: 978-562-4681
3/8“ i.d.
Tubing
INSTRUCTIONS FOR THE NU-MAtic
Nu - 15FS 20FS
VAKuum Klamping Set Up
VAKuum Jig
Male Quick Disconnect
Female Quick Disconnect
Hose Adapter
Y Adapter
1/2“ i.d. Tubing
Compressed
Air
Use the Y hose to connect the two vacuum barbs into one line for vacuum clamping.
3 position toggle SWITCH
Make sure that when you are clamping you have the Toggle switch on “VAK-KLAMP.” Never have the switch on “VAK-BAG” when you are
clamping. Only use “VAK-BAG” when you are veneering.
Note on adjusting the gauges to ZERO!
In shipping, the gauge can get bounced around and not be at zero. Disconnect the air line, open the
box (4 screws on the bottom) and position the box so that the rubber grommet on the gauge is up. With
your fingernail, lift the grommet so that air gets into the body of the gauge. This will reset it to zero.
Conditions of sale
WARRANTIES AND DISCLAIMERS. SELLER MAKES NO WARRANTY, EXPRESSED OR IMPLIED,
CONCERNING THE PRODUCT OR MERCHANTABILITY OR FITNESS THEREOF FOR ANY PURPOSE,
except; (a) that the product shall conform to the description contained herein and to the specifications, if any ,
attached hereto; and (b) that the product does not infringe on any valid United S tates patent. Seller does not
warrant, however, that the use of the product, or articles made therefrom, either alone or in conjunction with
other material, will not infringe any United St ates Patent.
Liability Limitations. Buyer's exclusive remedy shall be for damages and no claim of any kind, whether as to
product delivery or for non delivery of product, and whether based on contract, breach of warranty , negligence
or otherwise, shall be greater in amount than the purchase price of the quantity of product in respect of which
damages are claimed. In no event shall Seller be liable for incidental or consequential damages, whether
Buyer's claim is based on contract, breach of warranty , negligence or otherwise.
CALL 1-800-547-5484 TODAY!
Quality VAKuum Products, Inc.
Or visit our site at www.qualityvak.com
74 Apsley Street Hudson MA 01749
Tel: 978-562-4680 - Fax: 978-562-4681
June 26, 2012