6 CORPORATE PARKWAY
GOOSE CREEK SC 29445
www quoizel com
. .
( )2 MOUNTING SCREWS
UNIVERSAL CROSSBAR
SUPPLY WIRE and
( )2 MOUNTING BALLS
, .
GROUND WIRE
( )
2 OUTLET BOX
SCREWS
( )
not supplied
FIXTURE CANOPY
ASSEMBLY / INSTALLATION INSTRUCTIONS
1 Before beginning the installation carefully unpack and identify all parts referring to
. , ,
the illustration
2 Turn the electrical power to installation point OFF at circuit breaker
. .
3 Remove KNURLED NUT from the NIPPLE and thread the HEX NUT end of the NIPPLE
.
into the HEX COUPLING underside of the JUNCTION BOX Using plier, thread HEX
NUT against the HEX COUPLING and hand tighten until snug. Proceed to pass the
SPACER TUBE and the CHECK RING over the end of the NIPPLE Secure with the
KNURLED NUT and hand tighten until snug
4 Locate the PLAIN WASHER and SHADE over the end of the NIPPLE and secure with
.
the FINIAL. Hand tighten until snug
.
.
.
.
.
SOCKET
NIPPLE with KNURLED
NUT and HEX NUT
CHECK RING
SHADE
HEX COUPLING
SPACER TUBE
PLAIN WASHER
5 Locate the 2 MOUNTING SCREWS and thread them into the back of the
.
UNIVERSAL CROSSBAR making sure that they match the holes in the FIXTURE
CANOPY Using 2 OUTLET BOX SCREWS not supplied fasten the UNIVERSAL
CROSSBAR to the OUTLET BOX
6 Using wire connectors not supplied connect the
.
MAKING THE CONNECTIONS:
HOUSE GROUND WIRE to the FIXTURE GROUND WIRE connect the HOUSE
WHITE WIRE to the FIXTURE SUPPLY WIRE WHITE or RIBBED SIDE connect
the HOUSE BLACK or RED WIRE to the FIXTURE SUPPLY WIRE BLACK or
SMOOTH SIDE Wrap each connection with approved electrical tape
7 Carefully tuck all of the wiring up into the outlet box and fit the FIXTURE CANOPY
. ,
over the MOUNTING SCREWS Secure the FIXTURE CANOPY to the ceiling with
the 2 MOUNTING BALLS making sure that the balls are fully threaded onto the
( ) ,
MOUNTING SCREWS before tightening
8 Install bulbs referring to fixture markings and or labels for maximum wattage
.
9 Restore power to installation point ON Retain this sheet for future reference
. . .
( )
,
. ( ) ( ),
.
( )
;
( );
( ) (
). .
.
.
/ .
IF IN DOUBT ABOUT ELECTRICAL INSTALLATION,
CONSULTA LICENSED ELECTRICIAN!
FINIAL
IS TFIK1714
Revised 2009-03-06
-