Quoizel LRM5006WT User Manual

Assembly Instruction Sheet #IS-LRM5006WT
6 CORPORATE PARKWAY GOOSE CREEK SC 29445 www quoizel com
..
Quoizel, Inc. 6 Corporate Parkway Goose Creek, SC 29445
Customer Service Phone 631.273.2700 Fax 631.231.7102 www.quoizel.com
Warnings and Cautions
Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly recommend that a licensed, professional electrician perform the installation.
Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool before removal. Do not subject glass parts to any shock while in operation or shattering may result.
Do not touch the bulb with bare hands use a cloth or glove.
,.
For Style LRM5006WT
ToolsRequired: Flatheadscrewdriver, Phillipsscrewdriver,pliers,wire cutters, wire strippers, electricaltape,
BulbRecommended: EstimatedAssembly Time: Preparation:
belowto be sure all partsarepresent. If any parts aremissing or damaged, do not attemptto assemble, install, or operatethe fixture. Contact customer serviceforreplacement parts.
Identifyand inspect all parts beforebeginninginstallation. Check package content listand diagrams
(6)Candelabra Base 60W Maximum, Alternate bulb (6) 13WCFL
30-45minutes
Package Contents
Fixture Loop
A
x1
Rot
B
x1
Candle Cover
C
x6
Lock Ball
D
x3
Finial
E
x1
STEP 1 Adjust Fixture Assembly-
A. Unfold support arms on fixture
assembly to proper locations.
STEP 2 Install Fixture Body
A. Thread the Fixture Loop A , the
B. Pass Lock Ball (D) through
-
and Fixture Loop together
() (F)
Rod B and the Fixture Body together as shown. Hand tighten until snug. Fixture Body (F), hand tighten until sung.
support arm, secure by threading Lock Ball (D) into Fixture Body (F), hand tighten until sung.
Thread Finial (E) onto
()
B
Figure 2
Fixture Body
F
x1
Figure 1
QUOIZEL
R
Crossbar
AA
x1
Lock Washer
BB
x2
Hex Nut
CC
x2
Nipple
DD
x1
Canopy
EE
Chain Loop x1
STEP 3 Install Crossbar-
A. Attach the Crossbar (AA) to
the Outlet Box with the head of the Green Ground Screw facing you. Secure it with Outlet Box Screws (not included) Tighten until snug
STEP 4 Install Canopy Chain Loop and Nipple-
* Pliers is required for this step.
A
F
D
E
A. Thread one Hex Nut (CC) to one end of the Nipple (DD) until it is at
least 0.25” from the end. Pass one Lock Washer (BB) over the end of the Nipple (DD) and thread the Canopy Chain Loop (EE) onto the Nipple (DD). By using pliers, thread the Hex Nut (CC) against the
Canopy Chain Loop (EE) and hand
tighten until snug.
B. Thread another Hex Nut (CC) to the
middle of the Nipple (DD). Place another Lock Washer (BB) over the Nipple (DD) and then thread the Nipple (DD) into the Crossbar (AA) until the Nipple (DD) is about 0.375” above the Crossbar (AA).
C. Remove the Canopy Lock Ring (FF) from
the Canopy Chain Loop (EE). Place the Ceiling Canopy (II) over the Canopy Chain Loop (EE) against the ceiling to determine the correct position of the Nipple (DD). Thread the Canopy Lock Ring onto the Canopy Chain Loop (EE).
..
Figure 3
Hardware Contents
Canopy Lock Ring
FF
x1
Fixture Chain
GG
x1
Quick Link
HH
x2
Ceiling Canopy
II
x1
Outlet Box
AA
Outlet Box Screw (not
Green Ground Screw
BB
AA
CC
EE
Figure 4
included)
CC
DD
BB
Step B
Step A
II
FF
2014 Quoizel Inc.
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
1of3
May2014
Adjust the Nipple (DD) to allow the Ceiling Canopy (II) to rest against the ceiling when held in place by the Canopy Lock Ring (FF).
D. Remove the Canopy Lock Ring (FF) and the Ceiling Canopy (II).
Tighten the Hex Nut (CC) against the Crossbar (AA) to secure in place.
STEP 5 - Install Fixture Chain and Ceiling Canopy
A. Adjust the Fixture Chain (GG) to your desired length by removing
the links if needed.
*
Pliers is required for this step.
B. With the Fixture Chain (GG) not attached to the Fixture Loop (A) and
the Canopy Chain Loop (EE), pull the supply wires through the Fixture Chain (GG) alternating links.After the wires are through the Fixture Chain (GG), pull the Supply Wires and the Ground Wire through the Canopy Lock Ring (FF) and the Ceiling Canopy (II) in order.
C. Attach one end of the Fixture Chain (GG) to the Fixture Loop (A) with
one Quick Link (HH). Lift the fixture and Fixture Chain (GG) up And Attach the other end of the Fixture Chain (GG) onto the Canopy Chain Loop (EE) with another Quick Link (HH). The fixture will now hang safely. Close the chain loop at the Ceiling Canopy Loop (EE).
D. Feed the Supply Wires and Ground Wire through the Canopy Chain
Loop (EE) and Nipple (DD) into the Outlet Box. Cut the wires leaving
approximately 8” of wire extending from the Outlet Box. E. Refer to Step 5 for wire connections. F. Raise the Ceiling Canopy (II) and Canopy Lock Ring (FF) up the
Fixture Chain (GG) and over the Canopy Chain Loop (EE). Tighten
the Canopy Lock Ring (FF) onto the Canopy Chain Loop (EE) until
tight.
Suggested chain length for Ceiling height :
8’ ceiling : use 1 links of chain and 2 quick links
9’ ceiling : use 10 links of chain and 2 quick links
10’ ceiling : use 19 links of chain and 2 quick links
STEP 6 - Wire Connections
A. Use standard wire connectors (not included) to make all wire
connections. (Connectors are not included with fixture.) Strip and prepare wire ends according to instructions supplied with connectors.
B. Connect White Supply Wire from the Outlet Box to Ribbed side Wire
from fixture.
C. Connect Black (or Red) Supply Wire from the Outlet Box to Smooth
side Wire from fixture.
D. Connect Ground Wire from the Outlet Box to Ground Wire from
fixture. E. Twist connectors until wires are tightly joined together. F. Wrap each connection with approved electrical tape and carefully
stuff all the connected wires into the Outlet Box.
White wire
from supply
Black wire from supply (or Red)
Ground wire
from supply
Ribbed side wire from fixture
Smooth side wire from fixture
Ground wire from fixture
Figure 6
STEP 7 Install Candle and Bulbs-
A. place Candle Cover (C) over the Socket. B. This fixture uses candelabra bulb with standard screw base.
Maximum 60 watts.
C. Insert bulb and screw snugly into place.
Your fixture is now assembled and ready to use. Enjoy!
Supply Wires
and Ground Wire
GG
DD
HH
HH
FF
EE
A
Bulb
C
Socket
II
Figure 7
Figure 5
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
2of3
May2014
Loading...
+ 1 hidden pages