Quoizel ER5103IS User Manual

AssemblyInstructionSheet#IS-ER5103
ForStylesIS,PNandER5103BNER5103ER5103
Quoizel,Inc. 6CorporateParkway GooseCreek,SC29445
CustomerService Phone631.273.2700 Fax631.231.7102 www.quoizel.com
BulbRecommended: EstimatedAssemblyTime: Preparation:
belowtobesureallpartsarepresent.Ifanypartsaremissingordamaged,donotattempttoassemble,install,or operatethefixture.Contactcustomerserviceforreplacementparts.
Identifyandinspectallpartsbeforebeginninginstallation.Checkpackagecontentlistanddiagrams
(3)MediumBase100WbulbsMaximum,Alternatebulb(3)23WCFLMaximum.
30-45minutes
WarningsandCautions
Turnoffelectricityatcircuitbreakerormainfuseboxbeforeinstallation.Consultalicensedelectricianifindoubt. Theseinstructionsareprovidedforyoursafety.Itisveryimportantyoureadthemcompletelybeforeinstallingthefixture.Westrongly
recommendthatalicensed,professionalelectricianperformtheinstallation. Disconnectfixturefrompowersourcebeforereplacingbulbs.Makesurebulbsaregivensufficienttimetocoolbeforeremoval.Donotsubject
glasspartstoanyshockwhileinoperationorshatteringmayresult.
PackageContents
FixtureLoop
A
x1
6”Rod
B
x2
12Rod
C
x2
UpperCollar
D
x3
E
SteelCollar
F
x3
SocketCollar
G
x3
Shade x3
SuggestedrodsforCeilingheight: 8’ceiling:use(1)6rodand(1)12rod 9ceiling:use(1)6rodand(2)12rods
A
B
Figure1
SupplyWires
andGroundWire
B
C
C
Socket Assembly
H
x1
HardwareContents
Crossbar
AA
x1
LockWasher
BB
x2 HexNut
CC
x2
Nipple
DD
x1
STEP1AssembletheRodsandtheFixtureLoop-
A.DeterminetheRods(B/C)tobeassembledtotheSocketAssembly
(H)accordingtoyourhangingheight.
B.Passthesupplywiresandgroundwirethroughthechosenrods
(B/C)andtheFixtureLoop(A).ThreadtheSocketAssembly(H),the chosenRods(B/C)andtheFixtureLoop(A)together.Handtighten untilsnug.
Needassistancewithpartsorassembly?CallQuoizelcustomerserviceat1-631-273-2700
2014QuoizelInc.
CanopyChainLoop
EE
x1
CanopyLockRing
FF
x1
QuickLink
GG
x1 CeilingCanopy
HH
x1
ThankyouforpurchasingaQuoizelproduct.
orvisituson-lineatwww.quoizel.com
H
STEP2InstallCrossbar-
A.AA)AttachtheCrossbar(totheOutletBoxwiththeheadofthe
GreenGroundScrewfacingyou.SecureitwithOutletBoxScrews (notincluded)Tightenuntilsnug..
OutletBox
AA
OutletBoxScrew (notincluded)
GreenGroundScrew
STEP3InstallCanopyChainLoopandNipple-
* Pliersisrequiredforthisstep.
A.ThreadoneHexNut(CC)tooneendoftheNipple(DD)untilitisat
least0.25fromtheend.PassoneLockWasher(BB)overtheend oftheNipple(DD)andthreadtheCanopyChainLoop(EE)ontothe Nipple(DD).Byusingpliers,threadtheHexNut(CC)againstthe CanopyChainLoop(EE)andhandtightenuntilsnug.
B.ThreadanotherHexNut(CC)tothemiddleoftheNipple(DD).
PlaceanotherLockWasher(BB)overtheNipple(DD)andthen threadtheNipple(DD)intotheCrossbar(AA)untiltheNipple(DD)
1of3
Figure2
March2014
isabout0.375abovetheCrossbar(AA).
C.RemovetheCanopyLockRing(FF)fromtheCanopyChainLoop
(EE).PlacetheCeilingCanopy(HH)overtheCanopyChainLoop (EE)againsttheceilingtodeterminethecorrectpositionofthe Nipple(DD).ThreadtheCanopyLockRingontotheCanopyChain Loop(EE).AdjusttheNipple(DD)toallowtheCeilingCanopy(HH) torestagainsttheceilingwhenheldinplacebytheCanopyLock Ring(FF).
D.RemovetheCanopyLockRing(FF)andtheCeilingCanopy(HH).
TightentheHexNut(CC)againsttheCrossbar(AA)tosecurein place.
BB
DD
CC
EE
FF
CC
BB
AA
STEP4-InstallFixtureChainandCeilingCanopy
A.WiththeQuickLink(GG)notattachedtotheFixtureLoop(A)and
theCanopyChainLoop(EE),pullthesupplywiresthroughthe CanopyLockRing(FF),theCeilingCanopy(HH)andtheQuickLink (GG)inorder.
B.ConnecttheFixtureLoop(A)totheCanopyChainLoop(EE)with
theQuickLink(GG).
C.FeedtheSupplyWiresandGroundWirethroughtheCanopyChain
Loop(EE)andNipple(DD)intotheOutletBox.Cutthewiresleaving
approximately8”ofwireextendingfromtheOutletBox. D.RefertoStep5forwireconnections. F.RaisetheCeilingCanopy(HH)andCanopyLockRing(FF)upthe
QuickLink(GG)andovertheCanopyChainLoop(EE).Tightenthe
CanopyLockRing(FF)ontotheCanopyChainLoop(EE)untiltight.
StepB
StepA
HH
Figure3
STEP5-WireConnections
A.Usestandardwireconnectors(notincluded)tomakeallwire
connections.(Connectorsarenotincludedwithfixture.)Stripand preparewireendsaccordingtoinstructionssuppliedwith connectors.
B.ConnectWhiteSupplyWirefromtheOutletBoxtoRibbedsideWire
fromfixture.
C.ConnectBlack(orRed)SupplyWirefromtheOutletBoxtoSmooth
sideWirefromfixture.
D.ConnectGroundWirefromtheOutletBoxtoGroundWirefrom
fixture. E.Twistconnectorsuntilwiresaretightlyjoinedtogether. F.Wrapeachconnectionwithapprovedelectricaltapeandcarefully
stuffalltheconnectedwiresintotheOutletBox.
Whitewire
fromsupply
Blackwirefrom supply(orRed)
Groundwire
fromsupply
Figure5
STEP6-InstallShade
A.PlacetheUpperCollar(D),theShade(E)
andtheSteelCollar(F)ontotheSocket Assembly(H)inturnandsecurewiththe SocketCollar(G).Handtightenuntil snug.
Figure6
STEP7-InstallBulb
A.Thisfixtureusesstandardbulbwith
mediumbase.Maximum100watts.
B.Insertbulbandscrewsnuglyintoplace.
Yourfixtureisnowassembledandready touse.Enjoy!
Ribbedsidewire fromfixture
Smoothsidewire fromfixture
Groundwire fromfixture
Socket
D
E
F
G
SupplyWires
andGroundWire
2014QuoizelInc.
HH
DD
EE
GG
FF
A
Figure4
ThankyouforpurchasingaQuoizelproduct.
Needassistancewithpartsorassembly?CallQuoizelcustomerserviceat1-631-273-2700
orvisituson-lineatwww.quoizel.com
2of3
Figure7
Bulb
March2014
Loading...
+ 1 hidden pages