6 CORPORATE PARKWAY
GOOSE CREEK SC 29445
www quoizel com
..
Quoizel, Inc.
6 Corporate Parkway
Goose Creek, SC
29445
Customer Service
Phone 631.273.2700
Fax631.231.7102
www.quoizel.com
Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read them completely before installing
the fixture. We strongly recommend that a licensed, professional electrician perform the installation.
Preparation:Identify and inspect allpartsbefore beginning installation. Checkpackage
contentlist and diagrams belowtobe sure all partsarepresent. If any partsaremissing
ordamaged, do not attempttoassemble, install, or operatethefixture. Contact customer
servicefor replacement parts.
Warnings and Cautions
For Styles DE8960IB
Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool
before removal. Do not subject glass parts to any shock while in operation or shattering may result.
A
Package Contents
Part
ACrossbar
B
C
D
E
F
G
H
I
J
K
L
Description
Mounting Screw
Lock Washer
Hex Nut
Mounting Ball
Finial Assembly
Fixture Body
Large Glass Panel
Lock Screw
Loog Tab
Small Glass Panel
Short Tab
Quantity
1pc.
2 pcs.
2 pcs.
2 pcs.
2 pcs.
1pc.
1pc.
4 pcs.
8 pcs.
4 pcs.
4 pcs.
4 pcs.
B
C
D
E
F
G
I
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
2011 Quoizel Inc.
L
Thank youfor purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
1of7
H
K
J
April 2012
Page 2
DE8960IB
FINISH: IMPERIAL BRONZE
3
11”
14”
11”
2
(3)60W Candelabra
base bulbs
(not Supplied)
PART NUMBER
NO.
1
M380CCIB
5
4
5”
NOTE: ALL DIMENSIONS ARE ROUNDED UP TO THE NEAREST 1/2"
REPLACEMENT PART DESCRIPTION
CDCV IMPBRZ REPL CANDLE COVER
1
26”
12”
REQ.
3
2
3
4
5
M388FIIB
M280KTIB
G1200PA
G1199PA
FINL IMPBRZ REPL DE8960/8961IB
KIT IMPR BRNZ REPL
PANL LRG CLR BEV REPL DE8960IB
PANL SML CLR BEV REPL DE8960IB
2of7
1
1
4
4
Page 3
6 CORPORATE PARKWAY
GOOSE CREEK SC 29445
www quoizel com
..
,.
Assembly Instruction Sheet #IS-DE8960IB
For Styles DE8960IB
STEP 1Remove Fixture Hood from Glass
-
Frame
A. Prior to assembly, remove the Fixture Hood from the
Frame by unscrewing the Hex Coupling. Remove the
packaging material inside of the Frame.
STEP 2Attach Glass-
A. Slip Large Glass Panels (H) and Small Glass Panels
(K) inside of the Fixture Frame as shown. Locate Long
Tabs (J) onto the top edge of the Large Glass Panels
(H) and locate Short Tabs (L) onto the top edge of the
Small Glass Panels (K). Line up holes on Tabs onto
Mounting Holes in the Fixture Frame. Thread Lock
Screws (I) into mounting holes and hand tighten until
snug to secure the Glass Panels.
Figure 1
Short Tab
Small
Glass Panel
Fixture
Hood
Lock Screw
Fixture Body
Hex
Coupling
Frame
Loog Tab
Lock Screw
Large
Glass Panel
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
2011 Quoizel Inc.
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
3of7
Figure 2
April 2012
Page 4
6 CORPORATE PARKWAY
GOOSE CREEK SC 29445
www quoizel com
..
,.
Assembly Instruction Sheet #IS-DE8960IB
For Styles DE8960IB
STEP 3 - Attach Mounting Screws, Lock
Washers and Hex Nuts to Crossbar
A. Line up a set of holes on the Crossbar (A) and Holes on
the backplate of the Fixture Body (F).
B. Thread Mounting Screws (B) into the holes on the
Crossbar (A), pass Lock Washers (C) and thread Hex
Nut (D) onto the Mounting Screws (B). Hand tighten
until snug.
STEP 4 - Attach Crossbar to Outlet Box
A. Attach the Crossbar (A) to Outlet Box and secure by
threading Outlet Box Screws (not supplied) into the
Mounting Holes on the Outlet Box. Tighten until snug.
Mounting
Screw
Crossbar
Figure 3
Lock Washer
Hex Nut
Fixture
Body
Outlet
Box
Crossbar
STEP 5Attach Lanyard-
A. The purpose of the lanyard is to provide the installer a
means to support the fixture from the junction box while
connecting the electrical wires. This enables the fixture
to hang from the junction box and your hands are free to
make the wire connections.
B. TurntheButtonStopsoitmaybeinsertedintothe
crossbar slot. Make sure the Button Stop is completely
inside the crossbar. Slowly release the fixture to make
sure it is supported by the Button Stop. Proceed to the
wiring steps. Once you are complete with the wiring
there is nothing to do with Lanyard. The Lanyard will
push into the junction box when the fixture is placed for
final mounting.
Outlet Box
Screw
Mounting
Hole
Figure 4
Slot
Crossbar
Button Stop
Lanyard
Figure 5
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
2011 Quoizel Inc.
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
4of7
April 2012
Page 5
Assembly Instruction Sheet #IS-DE8960IB
6 CORPORATE PARKWAY
GOOSE CREEK SC 29445
www quoizel com
..
STEP 6Make Wire Connections-
A. Use standard wire connectors to make all wire
connections. (Connectors are not included with fixture.)
Strip and prepare wire ends according to instructions
supplied with connectors.
B. Connect White Supply Wire from the Outlet Box to White
Wire from fixture.
C. Connect Black (or Red) Supply Wire from the Outlet Box
to Black Wire from fixture.
D. Connect Ground Wire from the Outlet Box to Ground
Wire from fixture.
E. Twist connectors until wires are tightly joined together.
F. Wrap each connection with approved electrical tape and
carefully stuff all the connected wires into the Outlet Box.
White wire from supplyWhite wire from fixture
,.
For Styles DE8960IB
Figure 6
Black wire from supply
(or Red)
Ground wire from supplyGround wire from fixture
Black wire from fixture
Figure 7
STEP 7 - Attach Fixture Body to Mounting
Screw
A. Place the backplate of the Fixture Body (G) over the
Mounting Screws (B) and secure with Mounting Balls
(E). Hand tighten until snug.
Mounting Screw
Backplate
Mounting Ball
Figure 8
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
2011 Quoizel Inc.
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
5of7
April 2012
Page 6
Assembly Instruction Sheet #IS-DE8960IB
6 CORPORATE PARKWAY
GOOSE CREEK SC 29445
www quoizel com
..
STEP 8 - Install Bulb
A.standard bulb with a candelabra screw
This fixture uses
base0
B. Insert bulb and screw snugly into place.
,.
. Maximum 6 watts.
For Styles DE8960IB
Bulb
Socket
Figure 9
STEP 9Attach Fixture Hood to Glass Frame-
A. Place the center hole of the Fixture Hood over the top end
of the Stem, attach to the top edge of the Glass Frame.
Secure by threading the Hex Coupling onto the Stem.
Tighten until snug.
STEP 10Assemble Strut Member,
-
Waterproof Washer and Finial
A. Remove the Strut Member, the Waterproof Washer and
the Nipple from the Finial.
B. Screw one end of the Nipple into the Hex Coupling on
the top center of the Fixture Body (G). Hand tighten
until snug.
C. Pass the Strut Member and Waterproof Washer over
the top end of the Nipple. Thread the Finial onto the
Nipple and hand tighten until snug.
Figure 11
Waterproof
Hex Coupling
Fixture
Body
Stem
Washer
Hex Coupling
Fixture
Hood
Glass
Frame
Figure 10
Finial
Strut
Member
Nipple
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
2011 Quoizel Inc.
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
6of7
April 2012
Page 7
6 CORPORATE PARKWAY
GOOSE CREEK SC 29445
www quoizel com
..
,.
Assembly Instruction Sheet #IS-DE8960IB
For Styles DE8960IB
STEP 11Apply Silicone Sealer to Mounting
-
Balls
A. To prevent moisture from entering the wire
compartment, apply a small amount of silicone sealer
(not included) to the threaded side of the mounting
balls (E) and then install them onto the mounting
screws (B). Wipe off excess caulk.
STEP 12Apply Silicone Sealer to Backplate-
A. Make sure exterior wall surface and fixture backplate
are free of dirt before applying caulk. Using exterior
grade caulk, start on one side of fixture backplate and
follow contour, where the fixture backplate meets the
exterior wall surface upward. Proceed to caulk over top
of backplate and down other side. Do not caulk bottom
of fixture backplate to ensure proper moisture
drainage.
Figure 12
Mounting Ball
Outdoor Fixture
Backplate
Exterior
Grade Caulk
Your lamp wall fixture is now assembled and ready to
use. Enjoy!
Exterior Wall Surface
Figure 13
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
2011 Quoizel Inc.
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
7of7
April 2012
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.