Assembly Instruction Sheet #IS-COR8412K
For Style COR8412K
Quoizel, Inc.
6 Corporate Parkway
Goose Creek, SC 29445
Customer Service
Phone 631.273.2700
Fax 631.231.7102
www.quoizel.com
ToolsRequired: Flatheadscrewdriver, Phillipsscrewdriver,pliers,wire cutters, wire strippers, electricaltape,
safetyglasses.
BulbRecommended:
EstimatedAssembly Time:
Preparation:
Identifyand inspect all parts beforebeginninginstallation. Check package content listand diagrams
(1)Medium Base 150W bulb, Alternate bulb (1) 42WCFLMaximum.
30-45minutes
belowto be sure all partsarepresent. If any parts aremissing or damaged, do not attemptto assemble, install, or
operatethe fixture. Contact customer serviceforreplacement parts.
Fixturecan only be mounted inthedirection indicated on page 2.
Warnings and Cautions
Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly
recommend that a licensed, professional electrician perform the installation.
Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool before removal. Do not subject
glass parts to any shock while in operation or shattering may result.
Package Contents
Fixture Body
A
x1
Nipple (DD). Thread the Lock Ball (EE) onto the Nipple (DD). Adjust
the Nipple (DD) to allow the backplate of the Fixture Body (A) to rest
against the wall surface when held in place by the Lock Ball (EE).
D. Remove the Lock Ball (EE) and the Fixture Body (A). Tighten the
Hex Nut (CC) against the Crossbar (AA) to secure in place.
EE
CC
BB
DD
Hardware Contents
2.4mm
13Ga
GND
STEP 1 Install Crossbar-
QUOIZEL
R
AA
Crossbar
x1
BB
Lock Washer
x1
Outlet Box
CC
DD
EE
Hex Nut
x1
Nipple
x1
Lock Ball
x1
Figure 1
A. AA)Attach the Crossbar ( to the
Outlet Box with the head of the
Green Ground Screw facing you.
Secure it with Outlet Box Screws
(not included) Tighten until snug..
AA
Green
Ground
Screw
Outlet Box Screw
(not included)
STEP 2 Install Nipple-
* Pliers is required for this step.
A. Thread the Hex Nut (CC) to one end of the Nipple (DD) until it is at
least 0.25” from the end. Place the Lock Washer (BB) over the Nipple
(DD) and then thread the Nipple (DD) into the Crossbar (AA) until the
Nipple (DD) is about 0.375” above the Crossbar (AA).
B. Place the backplate of the Fixture Body (A) over the Nipple (DD)
against the wall surface to determine the correct position of the
AA
A
Figure 2
STEP 3 - Wire Connections
A. Use standard wire connectors (not included) to make all wire
connections. (Connectors are not included with fixture.) Strip and
prepare wire ends according to instructions supplied with
connectors.
B. Connect White Supply Wire from the Outlet Box to Ribbed side Wire
from fixture.
C. Connect Black (or Red) Supply Wire from the Outlet Box to Smooth
side Wire from fixture.
D. Connect Ground Wire from the Outlet Box to Ground Wire from
fixture.
E. Twist connectors until wires are tightly joined together.
F. Wrap each connection with approved electrical tape and carefully
stuff all the connected wires into the Outlet Box.
White wire
from supply
Black wire from
supply (or Red)
Ground wire
from supply
Ribbed side wire
from fixture
Smooth side wire
from fixture
Ground wire
from fixture
Figure 3
2014 QuoizelInc.
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
Thank you for purchasing a Quoizel product.
or visit us on-line at www.quoizel.com
1of2
Aprial2014

STEP 4 Install Fixture Body-
A. Carefully tuck all wires into the outlet box and position the backplate
of Fixture Body (A) over the outlet box. Pass the Nipple (CC)
through the holes on the backplate of the Fixture Body (A). Place
caulk (not supplied) into the previously removed Lock Ball (EE) and
then attach Fixture Body (A) using the Lock Ball (EE). Hand tighten
until snug.
EE
CC
STEP 6 - Apply Silicone Sealer
A. Make sure exterior wall surface
and fixture backplate are free of
dirt before applying caulk. Using
exterior grade caulk, caulk over
top of backplate and down other
side. Do not caulk bottom of
fixture backplate to ensure proper
moisture drainage.
Your fixture is now assembled and
ready to use. Enjoy!
Figure 6
Exterior
Grade Caulk
Backplate
Figure 4
A
STEP 5 Install Bulb-
A. This fixture uses standard bulb with medium
base. Maximum 150 watts.
Insert bulb and screw snugly into place.B.
Bulb
Figure 5
COR8412K
FINISH: MYSTIC BLACK
2.4mm
13Ga
QUOIZEL
GND
R
7”
(1)Medium Base
150W bulb
(not supplied)
PART NUMBER
NO.
1
2014 QuoizelInc.
24”
Fixture can only be
8.5”
mounted in the
direction indicated
9.5” Dia.
13”
NOTE: ALL DIMENSIONS ARE ROUNDED UPTO THE NEAREST 1/2"
REPLACEMENT PART DESCRIPTION
REQ.
Thank you for purchasing a Quoizel product.
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700
or visit us on-line at www.quoizel.com
2of2
6”
Aprial2014