1. Read Instructions - All safety and operation instructions must be read.
2. Retain Instructions - The safety and operating instructions should be kept for future reference.
3. Heed Warnings - All warnings should be followed.
4. Follow Instructions - All installing and operating instructions should be followed.
5. Water - The QuietCool system should not be used near water. If you live in a very humid climate, be sure
to cover your damper box with insulation to reduce condensation.
6. Heat - The QuietCool system should be situated away from heat sources.
7. Damage Requiring Service - Only qualified service personnel should service the QuietCool system.
The user should not attempt to service the product.
CONTENTS
1. SYSTEM OVERVIEW ...................................................... 1
1.1 Introduction ....................................................... 1
1.2 Features ..........................................................1
1.3 Benefits ...........................................................2
1.4 System Venting Requirements .....................................2
2. INSTALLATION ..........................................................3
2.1 Installing QuietCool ................................................3
3. WIRING .................................................................6
3.1 Single Speed Wiring ................................................ 7
3.2 Two Speed Wiring ..................................................8
3.3 Double Motor Head Two Speed Wiring ..............................10
4. SYSTEM OPERATING INSTRUCTIONS ...................................12
4.1 When to Run Fans .................................................12
4.2 Where to Start ....................................................12
4.3 Indoor Air Quality .................................................12
ENERGY SAVER CLASSIC WARRANTY ......................................13
QC Manufacturing, Inc.
43352 Business Park Drive
Temecula, CA 92590
PH 951.325.6340
FX 951.325.6351
QuietCoolSystems.com
2
QUIETCOOLSYSTEMS.COMQUIETCOOLSYSTEMS.COM
1. SYSTEM OVERVIEW
1.1 INTRODUCTION
Congratulations on the purchase of your new QuietCool system!
The QuietCool whole house fans dominate the market in energy efficiency and quietness. Whole house fans
operate by pulling the cool air from outside your home, through the home, into your attic, and out your attic
vents. This accomplishes a cooling effect that can save you up to 90% off your A/C related energy costs
depending on where you live. The difference between QuietCool and a standard whole house fan is a mix
between it’s astounding energy efficiency and it’s jaw-dropping sound level. A standard whole house fan
operates around 75dB; that’s equivalent to a loud vacuum cleaner running! In contrast, our QuietCool whole
house fans average at just around 45 dB; that’s equivalent to quiet conversation!
The QuietCool system uses a cutting edge, patented design to get our sound levels down to a respectable
level. Our fans suspend in the attic and use an acoustical duct that connects to a ceiling box and grille. The
result is an easy installation and quiet operation.
Once the air outside is cooler than the indoor air, crack open a few windows, turn your QuietCool on, and
enjoy the hot air being sucked out of your home and pushed out of your attic with a nice, cool breeze. While
performing 15-22 complete air exchanges per hour, the QuietCool whole house fan system will force the hot
stale air out of the attic which will help your house stay cooler during the hotter hours of the next day!
1.2 Features
• High Efficiency ECM Motor
• Patented Design
• Made in USA
• R5 Insulated Dampers
• 10 Year Warranty
1-888-QUIETCOOL
3
11-888-QUIETCOOL
1.3 Benefits
1.4 System Venting Requirements
VERY IMPORTANT! - 1 SQUARE FOOT OF NET FREE VENTING PER 750 CFM
REQUIRED VENTILATION: 1 SQ. FT FOR EACH 750 CFM
Vent Type Model Type Average Size Venting Sq. Ft.
Gable vent
Dormer Vent
Eave Vent
Ridge Vent
12” x 19.5” 1.20
14” x 8” 0.70
Various Various
Various Various
Soffit Vent Various Various
2
QUIETCOOLSYSTEMS.COM
2. INSTALLATION
2.1 Installing QuietCool
NOTE: Be sure to plug in your fan before
attempting to install to ensure that the fan is operational. If the fan is not operational, call the company that you purchased the fan from and request an exchange.
Installing the QuietCool system is very easy. Simply follow the steps given below:
1. Determine from down below in which areas you would like to install your QuietCool fans. Go up into the attic to mark the exact location for each fan. Take the cardboard cut-out template and a small screwdriver with you. Make sure the template fits between the framing.
The rough opening size varies depending on which model of QuietCool fan you are installing:
QuietCool Fan Model Rough Opening
ES-1500 14-1/4” x 14-1/4”
ES-2250 14 1/4” x 18-1/4”
ES-3100 14 1/4” x 22 1/4”
ES-4700 14 1/4” x 30 1/4”
ES-6400 14-1/4” x 36-1/4”
2. When you have chosen your exact spot, place the template on the spot and mark it at each corner by pushing the screwdriver through at each corner to make a hole so that you can find it from below.