Quest Engineering 105 Dual, 155 Dual, 205 Dual, 255 Dual, 4032270 Quick Start Instructions

...
(877) 420-1330
QUESTHYDRO.COM
TS-989 REV. C
QUICK START
INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS.
For a complete manual, go to www.questhydro.com/manuals
so that installation, operation and maintenance can proceed
successfully. Ultimate satisfaction depends on the quality of
installation and a thorough understanding of this equipment.
The dehumidifier is built around tested engineering principles
and has passed a thorough inspection for quality of workmanship
and function.
QUEST DUAL 105 / 155 / 205 / 225
A. DEHUMIDIFIER (1)
b. FEET (4)
C. COMPRESSOR PLUGS (2)
D. DRAIN HOSE (1)
E. DRAIN ADAPTER (1)
¾” NPT PVC TO 5/8” HOSE BARB
A. IF YOU PLACE ON FLOOR,
ATTACH LEVELING FEET.
IF YOU HANG DEHUMIDIFIER,
USE 2 bRACKETS* PER UNIT.
* BRACKETS SOLD SEPARATELY.
C. IF YOU PLACE THE DEHUMIDIFIER OUTSIDE THE GROW ROOM, SEE SECTION 14 ON THE FOLLOWING PAGE.
UNPACK BOX. REGISTER WARRANTY AT
THERMASTOR.COM/REGISTRATION
CHECK THAT YOU HAVE ALL PARTS:
READ ALL REMAINING STEPS AND WARNINGS BEFORE CONTINUING.
CHOOSE WHETHER TO PLACE ON FLOOR OR HANG DEHUMIDIFIER.
ATTACH FILTER DOORS.
CUT AND REMOVE SHIPPING ZIP TIE, INSERT COMPRESSOR PLUGS.
DECIDE WHERE TO PLACE UNIT IN GROW ROOM.
WARNING! DON’T BLOCK
AIRFLOW INLET. OUTLET
MUST BE AT LEAST 12 INCHES
FROM WALLS AND OTHER
OBSTRUCTIONS.
ASSEMBLY &
INSTALLATION
Thanks for purchasing a Quest Dual dehumidifier. For a complete manual, visit www.questhydro.com/manuals. Please follow these steps to successfully assemble and install your new dehumidifier.
QUEST DUAL DEHUMIDIFIERS CAN RUN WITHOUT ADDITIONAL ACCESSORIES. DEPENDING ON INSTALLATION, YOU MAY
REQUIRE ADDITIONAL PARTS. SEE STEP 14 FOR ADDITIONAL INFORMATION
1 2
3
4
7
8
5 6
A.
D.
b.
E.
C.
BEFORE TURNING ON UNIT:
1. CUT AND REMOVE ZIP TIE
2. PLUG HOLES USING INCLUDED PLUGS
BEFORE TURNING ON UNIT:
1. CUT AND REMOVE ZIP TIE
2. PLUG HOLES USING INCLUDED PLUGS
HERE IS ONE WAY TO HANG YOUR DEHUMIDIFIER:
* RECOMMEND 4” OFF GROUND
SEE MANUAL FOR MORE DETAILS
A. ATTACH A P-TRAP TO PREVENT AIR INTAKE
(AVAILAbLE AT MOST HARDWARE STORES.)
b. IF YOU NEED WATER
TO TRAVEL A FURTHER DISTANCE, SEE SECTION 14 bELOW ON HOW TO ORDER A PUMP KIT.
A. TURN ONbOARD KNOb
TO DESIRED SETTING.
b. IF YOU PREFER
EXTERNAL CONTROLS, SEE SECTION 14 bELOW ON HOW TO ORDER.
REMINDER: ONBOARD
KNOB NEEDS TO BE SET TO OFF TO USE EXTERNAL
CONTROLS.
INSERT DRAIN ADAPTER AND ATTACH DRAIN HOSE* TO UNIT.
PLUG IN UNIT.VERIFY WALL OUTLET IS CORRECT
VOLTAGE AND AMPERAGE.
OUTPUT TO DRAIN OR BUCKET.
UNIT
105 DUAL
4032270
155 DUAL
4031490
205 DUAL
4033060
225 DUAL
4035400
Supply Voltage 110-120 VAC 110-120 VAC 110-120 VAC 208-240 VAC
Current Draw 4.9 Amps 8.0 Amps 13.2 Amps 6.9 Amps
Operating Temperature 56°F Min - 95°F Max 56°F Min - 95°F Max 56°F Min - 95°F Max 56°F Min - 95°F Max
Air Filter MERV-11 Size: 16”x20”x2” MERV-11 Size: 16”x20”x2” MERV-11 Size: 16”x20”x2” MERV-11 Size: 16”x20”x2”
Weight 140lbs 140lbs 150lbs 150lbs
PERFORMANCE @ 80°F AND 60%RH
Capacity 105 Pints / Day 155 Pints / Day 205 Pints / Day 225 Pints / Day
Eciency 8.8 Pints / kWh 7.3 Pints / kWh 5.7 Pints / kWh 6.1 Pints / kWh
Power Cord
*This unit requires a
dedicated 20A circuit
9
1211
13
14
10
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
H
U
M
I
D
N
O
R
M
A
L
D
R
I
E
R
OFFON
BEFORE TURNING ON UNIT:
1. CUT AND REMOVE ZIP TIE
2. PLUG HOLES USING INCLUDED PLUGS
HONEYWELL REMOTE HUMIDISTAT
QUEST DEH 3000R CONTROL
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
H
U
M
I
D
N
O
R
M
A
L
D
R
I
E
R
OFFON
BEFORE TURNING ON UNIT:
1. CUT AND REMOVE ZIP TIE
2. PLUG HOLES USING INCLUDED PLUGS
COM
FAN
24V
DEHU
*
DMPR
COM
FAN
24V
DEHU
*
DMPR
24V AC
COMP FAN
HONEYWELL REMOTE HUMIDISTAT
WIRING DIAGRAM
QUEST DEH 3000R CONTROL
WIRING DIAGRAM
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
H
U
M
I
D
N
O
R
M
A
L
D
R
I
E
R
OFFON
BEFORE TURNING ON UNIT:
1. CUT AND REMOVE ZIP TIE
2. PLUG HOLES USING INCLUDED PLUGS
BEFORE TURNING ON UNIT:
1. CUT AND REMOVE ZIP TIE
2. PLUG HOLES USING INCLUDED PLUGS
COM
FAN
24V
DEHU
*
DMPR
24VAC
COMP FAN
QUEST DEH 3000R CONTROL
WIRING DIAGRAM
BEFORE TURNING ON UNIT:
1. CUT AND REMOVE ZIP TIE
2. PLUG HOLES USING INCLUDED PLUGS
COM
FAN
24V
DEHU
*
DMPR
COM
FAN
24V
DEHU
*
DMPR
24VAC
COMP FAN
HONEYWELL REMOTE HUMIDISTAT
WIRING DIAGRAM
QUEST DEH 3000R CONTROL
WIRING DIAGRAM
Red
Black
ADJUST HUMIDITY.
ACCESSORIES
A. REPLACEMENT FILTER: Change filters each grow cycle for maximum performance.
b. bRACKETS: Recommended for hanging the dehumidifier overhead.
C. PUMP KIT: Allows for draining and transferring water when the unit is not hard plumbed or near a drain.
D. DUCT KIT: Direct airflow when placing the dehumidifier outside of your grow room.
E. EXTERNAL CONTROL: Ideal for overhead installation or with duct work.
F. CASTERS: Recommended for easy mobility.
NEED HELP? CALL US AT (877) 420-1330
TO PURCHASE ADDITIONAL ACCESSORIES FOR YOUR SYSTEM, VISIT QUESTHYDRO.COM/PRODUCT-CATEGORY/ACCESSORIES
* YOU CAN USE
PROVIDED HOSE,
OR INSTALL PVC TO
ROUTE WATER.
14ga 10’, NEMA 5-15P 14ga 10’, NEMA 5-15P 14ga 10’, NEMA 6-15P14ga 10’, NEMA 5-20P
WHO IS COVERED
This warranty extends only to the original end-user of the Quest Dual dehumidifier, and may not be assigned or transferred.
FIRST YEAR WARRANTY
Therma-Stor LLC warrants that for one (1) year the Quest Dual dehumidifier will operate free from any defects in materials and workmanship, or Therma-Stor LLC will,
at its option, repair or replace the defective part(s), free of any charge.
SECOND THROUGH FIFTH YEAR WARRANTY
Therma-Stor LLC further warrants that for a period of five (5) years, the condenser, evaporator and compressor of the Quest Dual dehumidifier will operate free of any
defects in material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the defective part(s), provided that all labor and transportation charges for
the part(s) shall be borne by the end-user.
END-USER RESPONSIBILITIES
Warranty service must be performed by a Servicer authorized by Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized
Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-Stor LLC Service Department, which will then arrange for covered warranty
service. Warranty service will be performed during normal working hours.
The end-user must present proof of purchase (lease) upon request, by use of the warranty card or other reasonable and reliable means. The end-user is responsible for
normal care. This warranty does not cover any defect, malfunction, etc., resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification,
unauthorized or improper repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC’s reasonable control.
LIMITATIONS AND EXCLUSIONS
If any Quest Dual Dehumidifier part is repaired or replaced, the new part shall be warranted for only the remainder of the original warranty period applicable thereto
(but all warranty periods will be extended by the period of time, if any, that the Quest Dual Dehumidifier is out of service while awaiting covered warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICAbLE TO THE QUEST DUAL DEHUMIDIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED bY LAW, INCLUDING MERCHANTAbILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE bY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY bE MADE AGAINST THERMA-STOR LLC bASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY QUEST DUAL DEHUMIDIFIER OR PART THEREOF bE LIAbLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, AND SOME DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO ONE OR bOTH OF THESE LIMITATIONS MAY NOT APPLY TO YOU.
LEGAL RIGHTS
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
WARRANTOR
THERMA-STOR LLC 4201 LIEN RD., MADISON, WI 53704 1-800-533-7533
QUEST DUAL DEHUMIDIFIER
LIMITED WARRANTY
READ AND SAVE THESE INSTRUCTIONS
• The device is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING.
• Install the unit with space to access the back or side panels for maintenance and service. DO NOT INSTALL UNIT WITH THE SERVICE PANELS INACCESSIBLE.
• Avoid directing the discharge air at people, or over the water in pool areas.
• If used near a pool, spa or water; be certain there is NO chance the unit could fall into the water, be splashed and that it is plugged into an outlet that is a GROUND FAULT INTERRUPT protected circuit.
• DO NOT use the device as a bench or table.
• DO NOT place the device directly on structural members. Provide vibration isolation in order to minimize operational vibration and/or noise.
• A drain pan MUST be placed under the unit if installed above a living area or above an area where water leakage could cause damage
• Never operate a unit with a damaged power cord. If the power cord is damaged it must be replaced by the manufacturer, its service agent, or similarly
qualified person in order to avoid a hazard.
• Make all electrical connections in accordance with the current edition of the NEC ANSI/NFPA 70 and any national and local codes or ordinances that may
apply
• Do not obstruct the air intake and exhaust. Maintain a .3 m (1 ft) clearance around the air intake and exhaust.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Loading...