Quasar PAG User Manual

U5047A PAG QUASAR INSTRUCTION MANUAL
PAG Quasar
All-Chemistry Charging System
Instruction Manual
CONTENTS
SECTION PAGE
U5047A PAG QUASAR INSTRUCTION MANUAL
SECTION 1
SAFETY
1.1 This manual contains important safety and operating instructions. Please read these fully and note all warnings before using the charger. Please follow all instructions and retain this manual for future reference.
1.2 PAG Quasar chargers are not intended for any use other than the charging of batteries and the powering of broadcast cameras as detailed in Section 2 , Specification, Page 3.
1.3 IMPORTANT: Use only on AC supplies 100V-250V, 47-63Hz or with PAG approved voltage converters. Connection of the supply to the unit should be made using only the standard lead provided with this equipment.
1.4 Protect the power cord from being walked on or pinched. Unplug this apparatus during lightning storms or when unused for long periods of time.
1.5 Ensure that the ventilation slots are not obstructed when in use, e.g. do not site the charger on a carpet, or cover when in use.
1.6 WARNING: Indoor use only. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
1 SAFETY 2
2 SPECIFICATION 3
3 INSTALLATION 6
5 SERVICING & REPAIRS 12
6 WARRANTY 14
1.7 Although the charger is reverse polarity and short circuit protected, extreme care should always be taken not to short circuit the battery itself. Rechargeable batteries can deliver power at a very high rate, and short circuiting even a partially charged battery could result in a fire or personal injury. PAG supplies a range of connector leads for most charging requirements, and does not accept responsibility for any other form of charging connection.
1.8 Do not disassemble the charger. There are no user-serviceable parts inside. Incorrect re-assembly may result in a safety hazard.
1.9 Double Insulation: When servicing use only identical replacement parts.
1
2
U5047A PAG QUASAR INSTRUCTION MANUAL
U5047A PAG QUASAR INSTRUCTION MANUAL
1.10 Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as the supply cord or plug has been damaged, liquid has been spilled, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. In this event you should seek advice from your nearest PAG Dealer, or direct from PAG Ltd., London, by telephoning +44 (0)20 8543 3131.
SECTION 2
SPECIFICATION
2.1 PAG Quasar range:
Model No. 9726
Two PAGlok connectors and two PP90 (2.1mm) connectors.
Model No. 9727
Two Snap-on compatible connectors and two PP90 (2.1mm)
connectors.
Model No. 9752
Two PAGlok connectors and two PP90 (2.1mm) connectors.Built-in Power Supply.
Model No. 9753
Two Snap-on compatible connectors and two PP90 (2.1mm)
connectors.
Built-in Power Supply.
2.2 Range of Batteries Charged:
Nickel-Cadmium batteries having nominal voltages of between
4.8V and 14.4V, and nominal capacities of between 1Ah and 10Ah.
Non-PAG batteries (other than Ni-Cd or Ni-MH) using appropriate
PAG Intelligent Charge Adaptor.
2.3 Battery Connections:
PAGlok connectors:
Patented professional connector compatible with all PAGlok batteries. Incorporates self-cleaning military-type beryllium-copper leaf contacts.
Snap-On compatible connectors:
Patented professional connector compatible with Li-Ion Time Batteries (Models 9366 and 9383), and most Anton-Bauer batteries (excluding Dionic batteries).
PP90 connectors:
Polarised connector suitable for 2.1mm coaxial DC power connectors. NOTE: centre pin negative.
2.4 Main Charge Program:
Auto Mode - automatically selects the correct charge current.
Manual selection - 2A or 3A charge current.
Li-Ion voltage-charge program only available with PAG intelligent
batteries or suitable PAG intelligent adaptor. PAG intelligent batteries automatically over-ride the Auto Mode or Manual selection, and control their own charge regime.
2.5 Recovery Charge:
This special program conditions the battery for a period of one hour. The charger will then automatically enter the Main Charge program, which will run until the battery is fully charged. This program also recovers PAG Li-Ion batteries which have been over-discharged to the point where the internal safety protection circuit has tripped.
Nickel-Metal Hydride batteries of reputable manufacture having
nominal voltages of between 4.8V and 14.4V, and nominal capacities of between 1Ah and 10Ah.
PAG Lithium-Ion batteries.
2.6 Ancillary Charging Programs:
The following programs may be automatically entered after charging:
Balancing Charge.
3
4
U5047A PAG QUASAR INSTRUCTION MANUAL
U5047A PAG QUASAR INSTRUCTION MANUAL
Self-adjusting Maintenance Charge (not applied to PAG Li-Ion
batteries).
2.7 Self Test Program:
The internal microcomputer constantly monitors the battery under charge or process as well as the operation of the charger’s own functions which will be shut down to a safe condition should any of the tests fail.
2.8 Camera Power Supply (Models 9752 & 9753 only):
These models feature a power supply rated 13.5V to 15V DC, 3.7A (50W nominal), and is intended for powering a camera only. Connector: XLR-4 (F), pin 1 negative, pin 4 positive.
2.9 Mains Input:
100-250V~. Frequency 47-63 Hz. Maximum power consumption 100W.
2.10 Output:
26V DC 4A peak.
2.11 Output Protection:
Charger protected against short circuit, open circuit, excess battery voltage and reverse battery voltage.
2.12 AC Mains Failure Protection:
Should mains failure occur during a charging program, or whilst the charger is connected, it will shut down to a safe condition.
EMC Directive 89/336/EU.Low Voltage Directive 73/23/EU.
2.16 Operating Temperature Range:
0ºC to 40ºC (+32ºF to +104ºF).
2.17 Overall Dimensions: Models 9726 & 9752:
72mm high x 135mm wide x 185mm deep (2.8" x 5.3" x 7.3" approx.).
Models 9727 & 9753:
80mm high x 135mm wide x 185mm deep (3.1" x 5.3" x 7.3" approx.).
2.18 Weight: Models 9726 & 9752: 882g (1.94lbs approx.). Models 9727 & 9753: 844g (1.86lbs approx.).
SECTION 3
INSTALLATION
3.1 All Quasar chargers are fitted with a mains input socket conforming to CEE22 (IEC socket). This is situated on the back panel. Mains supply connection to the charger should only be made using the standard lead supplied with this equipment.
2.13 User Interface:
The backlit LCD screen has a display area of 64mm x 15mm, which displays 2 lines of text, with 16 characters per line. The front panel incorporates a soft function switch for the selection of programs and interrogation of charge data.
2.14 Safety:
Designed to comply with electrical safety standard EN60065 and UL6500. NOTE: U.K. mains leads are fitted with a 1" fuse to BS1362 rated 5A as standard.
2.15 European Union Directives:
Complies with the following EU Directives:
3.2 Quasar chargers have been designed for use on AC mains supplies worldwide, and automatically accept supplies in the range 100-250V ~. Mains supply frequency must be in the range 47-63 Hz.
3.3 Quasar chargers may be operated from a vehicle 12V battery using the PAG Vehicle Battery-Power Converter, Model No. 9774.
3.4 PAG TECHNICAL SALES AND INFORMATION DESK: For further information, contact the PAG Technical Sales and Information Desk (London) on +44 (0)20 8543 3131, PAG USA Technical Sales and Information Desk on +1 818 760 8265, or your nearest PAG Authorised Service Centre. Alternatively, visit the PAG websites at www.paguk.com or www.pagusa.com
5
6
Loading...
+ 4 hidden pages