Please observe these following safety precautions when using your air conditioner.
Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury.
INSTALLATION PRECAUTIONS
• Due to the weight of this product, we recommend that you have a helper to assist in the installation. To avoid injury, use the proper method of lifting. Avoid any sharp
SAFETY PRECAUTIONS
edges.
• Make sure the window frame to be used can properly support this product.
• This product must be installed in accordance with all local codes and ordinances.
• Do not install the unit in places where inflammable gas, fumes or soot may be generated.
OPERATION PRECAUTIONS
• Operate your air conditioner from a stable 115 volt AC supply.
• Plug into a separate 15 amp grounded outlet only.
• Use of extension cords Avoid using extension cords. If there are no alternatives,
ensure that the cord is a UL listed 3-wire grounding type, rated 125 volts with a minimum current-carrying rating of 15 amps, number 14 or heavier wire.
• Use a 15 amp time delay fuse or a circuit breaker.
• Do not switch off by unplugging the power plug while it is operating. Press the OFF/ON pad to “OFF” before unplugging.
This symbol (with a white background) denotes an action that is PROHIBITED.
These symbols (with a blue background) denote actions that are COMPULSORY.
OPERATION PRECAUTIONS
WARNING
• Do not modify the length of the power cord or use an extension cord.
• Do not touch or operate with wet hands. Do not modify or damage the cord.
• Do not turn on the unit by inserting the power plug. Do not switch off the unit by pulling out the power plug.
• Avoid an extended period of direct airflow.
• Do not insert sticks, fingers or other objects into the unit.
• Do not try to repair the unit yourself.
• Plug in properly before operating and use a specified power cord.
• If abnormal conditions (burnt smell, etc) occur, switch off and remove the power plug.
CAUTION
• Do not use the unit for other purposes, than its intended use.
• Do not remove the power plug by pulling the cord.
• Do not block the air intake and outlet vanes.
• Do not splash or direct water at the unit
• Do not expose the unit to direct sunlight during operation.
• Do not operate the unit without the air filter installed or when the front intake grille has been removed.
• Do not place any objects on the unit.
• Do not operate any combustion equipment near the unit’s airflow area.
• Switch off the breaker and remove the power plug from the socket if the unit will not be operated for a long period.
• Pay attention to any damages on the unit caused by extensive usage.
• Ventilate the room occasionally where the unit is installed.
• Remove the power plug when cleaning the unit.
This sign warns of risk of death or serious injury.
This sign warns of injury or damage to property.
POWER SUPPLY
Time Delay Fuse : 15 Amps Rated Voltage : 115V
• Socket Type
• Line Cord Plug
2
INSTALLATION BOX CONTENTS
Sealer 50 g (1.8 oz) (Putty)
Type A screws
Type C screws
Type A screw
Left side expandable panel
Top sealing ribbon
To p angle
Type B screws
ACCESSORIES
AIR CONDITIONER INSTALLATION
NOTE Check that none of the accessories are missing.
Window sash foam seal
Type A screws
(6 pcs) (XTN5D25A)
(5 pcs) (CWH4580211)
(6 pcs) (XTT4D8C)
Window sash sealing ribbon
SCREW FURNISHED
Side sealing ribbon
Type A screw
Type A Type B Type C (Qty 6) (Qty 5) (Qty 6)
SUGGESTED TOOL LIST
Type C screws
Right side expandable panel
SELECT THE BEST LOCATION
(Single or Double
Window
hung window)
Front grille
SIDE VIEW
Wood Machine Tapping Screw Screw Screw
Medium sized screwdriver (#2 Phillips)
Tape Measure
Pencil
Level
Knife or Scissor
19–3/
inches
16
12 inches
More than 4 inches
WINDOW REQUIREMENTS
O F F / O
N
OP E R ATI
O N
T E M
P / T I
M E R
C O
O
L F A N
H I G
H M E
D L O
W
M O D
E
F A N
S
P E E
D
S E T
T I M
E R
S E
T
/ C A N
C
E
L
A I R
S W
I N G
E C O N O
M Y
h
r
°
F
W
i
r
e
l
e s
s
R e m
o
t
e
C
o n
t r o l
• Hot sun rays hitting the outside surface of the cabinet will create considerable heat load. If the outside of the cabinet is exposed to direct sunlight, consider building an awning to shade the cabinet while providing ample area for the heated air to be exhausted from the condenser (both sides) and the top.
(min)
16
/
15
15-
22
to 42-
1
/
8
This unit is designed for installation in standard double hung windows.
NOTE The unit may also be installed “through the wall”. You should, however, observe standard carpentry practices and frame the opening without violating local ordinances.
INSTALLATION PROCEDURES
CHASSIS INSTALLATION INTO THE CABINET
1 Slide the chassis into the cabinet.
2 Reinstall the cabinet screws.
Secure the cabinet to chassis by using screws (from rear cabinet).
1 Remove the rear cabinet
screws and save for later use.
2 Slide the chassis out from the
cabinet.
°
F
T I M E
O
R
P E R A T I
O
T
N
E M P/
TI M E
R
h
r
SE T
SE
O F
T /
F / O
N
CANCEL
C O O
L F A
M
N
O D
E
A I R
S W
I N
G H I
E
G
C
H
O N O M
Y
M E D
F A
N S
P E E
D L O W
W i r e
l e s
s
Remo
te C
ontr
ol
HOW TO ASSEMBLE THE EXPANDABLE PANELS
Top angle
Top sealing ribbon (To be attached to the
Expandable panel
top angle)
Type B screws
Side sealing ribbon (To be attached to the expandable panel)
NOTE This procedure applies to left and right
Type C screws
of assembling expandable panel.
• Attach the top angle to the cabinet using screw type B (3 pcs).
• Insert expandable panels to cabinet sides as shown.
• Secure the first fold of expansion panel to cabinet using screw type C (3 each).
CABINET INSTALLATION
1 Cut the “Sealing Ribbon” to the
proper length, and attach it along the bottom edge of the bottom window sash.
Window sash sealing ribbon
INSTALLATION OF THE FRONT GRILLE
Depending upon the location of the AC outlet, route the AC cord to either the left or right side while installing the front grille.
This figure shows the AC cord routed to the left side.
1 Place the front grille on the
cabinet first.
2 Secure the front grille to the
main chassis using screw provided.
Clockwise.
INSERT THE (OPTIONAL)
Attach the (part no. CZ-SF6P) to the frame.
Slot in the and the frame (part no. CZ-SFW6P) to the front grille.
°
F
T I M E
O
R
P E R
A T I O
T
N
E M
P / T
IM E R
h r
S
E T
SE
O F
T
/
F
/ O N
C A N C
E L
COO
L F A
MO
N
D E
AI R SW
IN G
HI
E
GH
C O
N O M
Y
MED
F A N
SP
EE
D L O W
W
ir
ele
ss
R
e m o
t e C
o n
t r o l
°
F
T I
M E
O
R
P
E R A
T I O
T
N
E
M
P
/
T I M
E R
h
r
S E
T
S
O
E
F
T
/
F
/ O N
C A
N C
E L
C O
O
L F A
M
N
O
D E
A I
R S
W I N
G H I
E
G
C
H
O N
O M
Y
M E
D
F A
N
S P E
E
D L O
W
W
i r
e l e
s s
R e
m o
t e C
o n t r
o l
°
F
T
IM E
O
R
P E R A
T I O
N
T E
M
P
/T
IM
E R
h
r
S E
T
O
S E
F
T
F
/
/O
N
C
A N C E
L
C O O L F A
M
N
O
D E
A I
R S
W I N
G
EC
H
ONOM
I G H
Y
M E D
F A
N S
P E
E
D L O W
Wireless
R e
m o te
C
o n tr
o l
2 To prevent condensation water
from dripping inside, the cabinet should be installed level or very slightly tilted to the outside.
3 Secure the cabinet using screws.
Type A screw
Type B screws
Inside of sash
Top angle
Expandable panel
Window sill
Type A screws
Window sash foam seal
• Expand the expandable panel fully into the grooves of the window frame, secure the expandable panel, left, right and top mounting frames to the bottom of the window sash using 6 screws type A and 2 screws type B.
• Secure the cabinet using wood screws type A.
• Cut the window sash foam seal to the proper size and seal the opening between the top of the inside window sash and the outside window sash.
Note :If a gap exists between the unit and window sash, you may
use “Sealer” supplied with the installation kit for a better seal.
Outside of sash
Window sash
Sealing ribbon
The and the frame can be obtained separately from your nearest service center.
INSERT THE AIR FILTER
Attach the air filter to the intake grille
°F
TIM ER
O P E R
ATIO
N
T E M
P / T
I M E
R
hr
S E T
O
S E
F
T
F
/
/O
N
C A N
C E L
C O
O
L F A
M
N
O D
E
A I R
S W
I N G
E C
H
O
I G
N
H
O
M Y
M E
D
F A N S
P E E
D L O
W
W
ire
less
R e m
o t e
C o
n t r o l
PLACE FRONT INTAKE GRILLE OVER THE FRONT GRILLE
Slide the front intake grille slightly to the right to reattach the tabs and then push it down to close tight.
°
F
T
I M
E
O
R
P E R
A T I O
N
T
E
M P
/ T IM
E R
h r
S
E T
O
S E
F
T
F
/
/ O N
C
A N C
E L
COOL
FAN
MODE
AIR SWING
E C
HIGH
O N
O M
Y
MED
FAN SPEED
LOW
W
i
r e l
e s s
R e
m o
t e C
o n tr
o l
2
REMOVAL OF FRONT GRILLE
1 Remove the front intake grille.
Pull up the front intake grille about 90° and slide it slightly to the left to unhook the tabs.
°F
TIM E
OP
R
E R
A T I O
N
T E M
P / T I M
E R
hr
S E T
O
S E
F
T
F
/
/ O N
C A N C E L
C O O L F A
M
N
O D
E
A
I R S
W I N
G
E C
H
O
I G
N
H
O M
Y
M E D
F A N S P
E E
D L O W
Wireless
R e
m o t e
C o
n t r o l
2 Remove the air filter.
Tilt up and pull out the air filter by the holder.
3 Remove the front grille.
aa
a
At bottom right side of the front grille, press inward on cabinet near the power cord, and pull
aa
the grille outward to the right until right tab releases.
bb
b
At the bottom left side, push inward on cabinet and pull the grille outward to the left to release
bb
the left tab. Do not pull the bottom edge toward you more than 3 inches to prevent the two top tabs from damage.
cc
c
Slide the front grille upwards to free the two top tabs from slots at the top of the cabinet.
cc
HOW TO ATTACH THE DRAIN PAN (OPTIONAL)
AIR CONDITIONER INSTALLATION
Condensed water drainage
This air conditioner employs a Slinger-Up System which is designed to splash the condensed water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound. If the splashing sound annoys you, you can provide an outside drainage by using the following procedure which may, however, cause a small loss of performance.
Note: The cabinet should be installed tilted slightly lower to the rear for necessary condensate
drainage. (Max. 13/32”)
1 Remove the rubber plug and slide the chassis out from
the cabinet.
3 Connect a drain hose (optional).
Fit the drain hose to the drain pan.
Note
N
IO
T RA E P O
R E TIM
N
/O
F F O
T E S
R
E M I T /
/
P
°F
T
M
E
E
S
T
L E C N A C
hr
Y M
O N O C E
G N
I W S R
I A
L
E D
O
O O C
M N
A
s
F
s
le
l
ire
o r t n
W
o C e t o
H
m e
G
I
R
H
D
E E P S N
A F
D E M
W O L
Remove the rubber plug
Drain hose or tubing can be purchased locally to satisfy your particular needs.
Air filter
°F
T I M E
O
R
P E R
A T I O
N
T E
M P / T
IM E R
h r
S E T
O
S E
F
T
F
/
/ O N
C A N C E
L
C
O O
L F A
M
N
O D E
A I R S
W I N
G
E C
H
O
I
G
N
H
O M
Y
M
E
D
F A N
S P
E E D
L
O
W
W
ir e
le
s s
R e
m o t e
C o
n t r o l
cc
c
cc
°
F
T
I M E
O
R
P E R
A T I O
T
N
E M P /T
IM E R
h
r
S E T
S
O
E
F
T /
F/
O N
C
A N C E
L
C
O
O
L F A
M
N
O D
E
A I R S
W I N
G H I
E
G
C
H
O N
O M Y
M E
D F
A N S
P E E
D L O
W
W
i r e
l e
s s
R e
m o t
e C
o n t r o
bb
b
bb
l
aa
a
aa
Maximum 13/32
Condensed water
EXTERNAL VIEW
Drain hose (not included)
Under-side view with drain pan and hose in place.
3
PART IDENTIFICATION
2 Install the optional drain pan (part no. CWH40175).
Install the drain pan at the right corner of the cabinet using 2
INTERNAL VIEW
screws (part no. CWG86C733).
Note The drain pan (part no. CWH40175) can be obtained
Screws
Drain pan (optional)
from nearest service center.
MAIN UNIT
1 Air inlet louver 4 Air filter (behind the
2 Cabinet 5 Front intake
3 Power cord 6 Front grille
7 Vertical airflow direction vane
(Airflow direction adjustment up­down). The vertical airflow direction vane is controlled by rotating the horizontal vane forward or backward.
4
5
8 Ventilation lever
1
2
6
7
8
9
3
The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary
°F
TIMER
O P E
R A
T
T
E
I O
M
N
P
/T IM
E R
h r
S E
T
S
E
OFF/ON
T
/ C A
N C
E
COOL
L
FAN
MODE
AIR SWING HIGH
MED
FAN SPEED
LOW
in the room, set the ventilation lever to the OPEN position. The
E C O
N
O M
Y
Wireless
Remote Control
damper is opened and room air is drawn out.
TYPES OF SIGNAL SOUND One long “Beep” and one short “Beep”. (Sound from the main unit.)
4 Slide the chassis back into the
cabinet. Reinstall the cabinet screws. Secure the cabinet to chassis by using screws.
9 Touch control panel
front intake grille)
grille
a Display Panel
°
F
T IM
E
O
R
P E
R A
T
T
E M
P / T
I M E
R
h r
S
E T
SET/
O F
F / O
CANCEL
C O
O
L F A
M
N
OD
E
A IR
S W
IN
G H IG
H
EC O
N O
M E
D
F A N S
P E E
D L O
W
W ireless
R e m o
te
C o
n tro
l
b MODE selection pad
I O N
N
M Y
c FAN SPEED selection pad d TEMPERATURE/TIMER
e TIMER pad f Timer SET/CANCEL pad g OPERATION OFF/ON pad h AIR SWING pad i ECONOMY pad
a
COOL
MODE
b
FAN
HIGH
FAN SPEED
MED
c
LOW
setting pad
°F
T
I M E
OP
R
E R AT IO
T
N
E M
P / T I M
E R
h r
S E
T
S
O
E
F
T
/
F / O
N
C
A N C
E L
C OOL
F AN
M ODE
AIR SWING
HIGH
E C
O N O M
Y
ME
D
FAN SPE
ED
LOW
W
ir
e le
s s
R
em ot
e C
ont ro
l
e
d
°F
TEMP/TIMER
hr
AIR SWING
TIMER
SET
SET/
CANCEL
f
h
Wireless
Remote Control
OPERATION
OFF/ON
ECONOMY
g
i
3
AIR SWING
PART
ACCESSORIES
Remote control Two R03 dry-cell batteries
REMOTE CONTROL
1 Signal Transmitter 2 OPERATION button 3 TEMPERATURE/TIMER setting button 4 TIMER button 5 TIMER SET/CANCEL button 6 MODE selection button 7 ECONOMY Button
IDENTIFICATION
8 AIR SWING button 9 Fan Speed Selection Button
4
6
AIR SWING
8
Be sure to observe the following:
Aim remote control at control
1
2
OPERATION
TEMP/TIMER
3
SET/
TIMER
CANCEL
5
ECONOMY
MODE
FAN SPEED
7
9
panel on air conditioner when operating.
Do not drop or throw the remote control.
Do not place the remote control in a location that is exposed to direct sunlight or next to a heating unit or other heat sources.
Maximum distance : 10 m (32.8 ft.)
°
C
T I M
E
O
R
P
E R A
T
T
E
IO
M
N
P
/ T I M
E R
h r
S
E T
S E
O
T
F
/
F / O
N
C A N
C E
C
L
OO
L
FA
M
N
O D
E
A I
R SWIN
G HI GH
P O
W E
R FU L
FA
N S P
E E
D L OW
W ir
e
l e s
R
s
em
o t e C
o n t ro
l
4
HOW TO INSERT BATTERIES
OPERATING
1
Open the cover.
PREPARATION BEFORE
5
CAUTION
OPERATING THE UNIT
OPERATION
OFF/ON
OPERATION
SETTING DISPLAY TEMPERATURE
TEMP/TIMER
TEMP/TIMER
WARNING
Ensure that the power plug is securely inserted.
A loose plug may cause a fire or an electric shock.
2
Insert the two batteries.
If the unit is not going to be used for an extended period of time, remove the power plug. Otherwise, approximately 2.5W of electricity will be used even if the unit has been turned off using the remote control.
If operation is stopped, and to be restarted immediately, the unit will resume operation only after 3 minutes.
3
Close the cover.
Do not use rechargeable (Ni-Cd) batteries because such batteries differ from the standard dry cell batteries in shape, dimension and performance.
NOTES
Start operation by pressing
°F
hr
OPERATION. The operation will turn on and the display panel will light up.
°F
hr
To stop the operation, press the OPERATION again. The unit will stop operating and the display panel light will turn off.
Press TEMP/TIMER or to set the
°F
hr
display temperature.
Display will change according to the setting.
The temperature can be set between 60°F and 86°F. Recommended temperature: 75°F ~ 78°F.
ABOUT THE BATTERIES
The batteries can be used for approximately one year.
Be sure to replace the batteries with two new identical
batteries.
Remove the batteries if the air conditioner will not be used for an extended period of time.
SELECTING OPERATION MODE
COOL
MODE
FAN
Press MODE to select the desired operation .
COOL
The indicator will light up and a “beep”
FAN
sound will indicate changing setting.
COOL mode
To set room temperature to your preference of cooling comfort.
FAN mode
To provide air circulation without cooling the room.
MODE
During Fan operation, temperature setting cannot be selected.
NOTES
The latest temperature setting will be memorized and will appear on the display the next time its turned on.
The display temperature selection is for display purpose only
AIR CONDITIONER OPERATION
and does not indicate actual room setting temperatures. Your room temperature may not necessarily match the displayed temperature.
SELECTING FAN SPEED
HIGH
MED
LOW
FAN SPEED
FAN SPEED
Press FAN SPEED to choose the
HIGH
speed level of the fan. The indicator will light up and the beep
MED
sound will indicate changing setting.
LOW
NOTE
The latest fan speed setting will be memorized and the indicator will light up the next time the unit is turned on.
ADJUSTING HORIZONTAL AIR FLOW DIRECTION
Press to select AIR SWING. The air circulation will automatically move the horizontal louvers left and right for better air distribution around the room.
NOTE Using your hands to adjust the direction may cause the louvers to malfunction. If this happens, stop
AIR SWING
operation immediately and restart.
NOTE
Vertical louvers
°F
T I M
E
O
R
P E
R A
T
T
E
IO
M
N
P /T
I M E
R
hr
S E T
SET/
O FF
/O
N
CANCEL
COOL
FAN
MODE
AIR SWING
HIGH
ECONOMY
MED
FAN SPEED
LOW
W
ire
le
s s
Remote Control
Vertical adjustment of the airflow direction is done manually.
5
TEMP/TIMER
OFF/ON
OPERATION
OPERATION
TEMP/TIMER
ECONOMY OPERATION
To reduce power consumption:
ECONOMY
ECONOMY
°F
hr
Press ECONOMY.
To cancel this operation, press once
more.
ECONOMY Recommended for electricity cost saving. When economy button is pressed, target temperature is shifted up 1°F, this will reduce operating time of the compressor and therefore reduce power consumption. It may, however, take a little longer for the compressor to cycle on and thereby increase the room temperature slightly. Economy mode will override your current set fan speed to LOW. However, the display will still show the current set fan speed. Compressor stops when the room temperature reaches the target temperature. It turns on again when the room temperature rises. When power failure occurs, the economy setting is canceled. Once power is resumed, reset the economy setting.
SETTING THE OFF TIMER
When the air conditioner in operation:
TIMER
°F
hr
Press the TIMER button. The SET/CANCEL indicator light will
AIR CONDITIONER OPERATION
TEMP/TIMER
SET
SET/
CANCEL
blink awaiting for setting.
°F
hr
Press the TEMP/TIMER or button until the preferred hour of operation is
°F
reached.
hr
Press the SET/CANCEL button to complete the setting. At this time, the SET/CANCEL indicator light is steady instead of blinking.
TIMER
NOTE The hour reading will change back to the set temperature reading after 10
TEMP/TIMER
SET/
CANCEL
seconds. (You can also revert to temperature setting immediately by pressing the TEMP/TIMER or buttons again.)
CHECK TIMER SETTING DURING OFF TIMER
Press the TIMER button to check the
°F
remaining programmed timer setting.
TIMER
hr
The figure will be displayed for 10
°F
seconds then will automatically switch
hr
back to temperature setting.
NOTE
TIMER
The timer figure will change according to the time remaining (if you set it to turn off 3 hours from now, the timer will show 2 at an hour later).
CANCEL TIMER SETTING DURING OFF TIMER
SET
SET/
CANCEL
SET/
CANCEL
Press the SET/CANCEL button to cancel
°F
the timer setting. The SET/CANCEL
hr
indicator light will turn off. However the temperature remains displayed.
SETTING THE ON TIMER
When the air conditioner in operation:
TIMER
°F
hr
Press the TIMER button. The TIMER indicator light will blink to await for setting.
°F
SET
SET/
CANCEL
Press the TEMP/TIMER
hr
until the desired hour for operation is reached. Press the SET/CANCEL button
°F
to complete the setting. At this time, the
hr
TIMER indicator light is steady instead of blinking.
°F
The display will show the remaining hour
hr
to the start of the operation (if you set to
or
turn on 3 hours from now, the timer will show “2” at an hour later).
TIMER
When set time is reached, the air conditioner starts the operation under the previous setting mode and the TIMER indicator will light off. Now, the previous
SET/
CANCEL
set mode and the fan speed will light up. Simultaneously, the display will show the setting temperature.
CHECK TEMPERATURE/MODE/FAN SPEED SETTING DURING ON TIMER
Press the TIMER button. The TIMER
TIMER
°F
indicator light will blink and the previous
hr
temperature setting will be shown.
°F
Simultaneously, MODE and FAN
hr
SPEED indicator will light up. This indication will last for 5 seconds, and then the display will show the remaining time. MODE and FAN SPEED indicator
TIMER
light will turn off. At this time, the TIMER indicator light is steady instead of blinking.
CHANGE TEMPERATURE/MODE/FAN SPEED SETTING DURING ON TIMER
SET
SET/
CANCEL
OPERATION
OFF/ON
TIMER
SET/
CANCEL
TIMER
Press the SET/CANCEL button to
°F
hr
cancel the timer setting. Press the OPERATION. Set the desired
°F
mode and the fan speed. Then press
hr
OPERATION button to stop operation. Start the TIMER setting again by
°F
repeating the step from the Setting the
hr
on timer procedures).
CANCEL TIMER SETTING DURING ON TIMER
SET
SET/
CANCEL
SET/
CANCEL
OPERATION
Press the SET/CANCEL button to cancel the
°F
timer setting. The SET/CANCEL indicator
hr
light will turn off. To operate the air
°F
conditioner before reaching the set timer:
hr
Press the SET/CANCEL to cancel the timer.
Press the OPERATION button to turn on the unit.
button
Model HQ-2102UH HQ-2122UH
6
COOLING CAPACITY Btu/h 10,000 11,500
ELECTRICAL RATING Phase Single +
EER (Btu/W.h) 10.2 +
MOISTURE REMOVAL (Pints/h) 2.5 3.0
ROOM AIR CIRCULATION (Cf/min) 320 330
DIMENSIONS Height cm (inches) 37.5 (14-
NET WEIGHT kg (lb) 35 (77) +
GROSS WEIGHT kg (lb) 39 (86) +
NOISE LEVEL Indoor (Hi/Lo) dB (A) 50/46 51/47
* Specifications are subject to change without notice for further improvement.
PRODUCT SPECIFICATIONS
Frequency (Hz) 60 + Voltage (V) 115 + Current (Amps) 8.7 9.8 Input (W) 980 1120
25
/32˝) +
1
Width cm (inches) 56 (22-
/16˝) +
Depth cm (inches) 60.6 (23-27/32˝) +
Outdoor (Hi/Lo) dB (A) 57/54 58/55
7
Random Auto Restart
Operation will automatically
If the unit was set to TIMER
Timer Setting
When power failure occurs, the
ENERGY SAVING HINTS
HELPFUL INFORMATION &
HELPFUL INFORMATION
resume under the previous operation mode.
mode, operation will not resume automatically.
timer setting is canceled. Once power returns, reset the timer.
ENERGY SAVING HINTS
Setting the temperature 1°F higher save 10% electricity costs.
Clean the air filter every 2 weeks. Regular cleaning of the air filter preserves efficiency.
Keeping openings closed keeps cool air in and hot air out.
Avoid direct sunlight and heat.
For health reasons do not overcool your
room.
Your air conditioners cooling capacity should match your room size.
8
CARE AND MAINTENANCE
9
CAUTION
Clean the cabinet, front grille with a mild soap or detergent and lukewarm water.
The front intake grille can be easily removed for cleaning purposes (refer to Remove the front intake grille procedures). Gently
wash it with water and a sponge.
The filter can be easily cleaned using a vacuum cleaner. Vacuum the front of the filter and then wash the rear with water. If it is badly soiled, wash with a mild household detergent. It is recommended to replace the (part no.CZ-SF6P) every 3 months.
Do not clean with benzene, thinner, scouring powder or cloth soaked in caustic chemicals.
If the unit is extremely dirty, heat transfer is less efficient and the unit may not cool effectively. Contact your nearest servicenter
for an annual check. (Annual check is not covered under warranty)
If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted.
NOTE Do not dry the front panel or the air filter in direct sunlight. (Exposure to direct sunlight may discolor or deform the panel.)
PRE-SEASON INSPECTION
Is the discharged air cold?
After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air to be more than 14.4°F for cooling.
Are the air intake and outlet vanes of the indoor and outdoor side obstructed?
Are the remote control batteries weak?
BEFORE
Always turn off the air conditioner and the main power supply before clean the unit. Switch off the power supply if the unit is not going to be used for a long period of time.
Check the following points before calling for repairs or service. If the malfunction persists, please contact your nearest service center. For assistance, please call: 1-800-211-PANA (7262) or send e-mail to: consumerproducts@panasonic.com
RECOMMENDED INSPECTION
Usage over several seasons will reduce performance as the unit becomes dirty. A dirty unit may produce foul odors and dust may clog the dehumidifying drainage. Seasonal inspection is recommended in addition to regular cleaning. Consult your nearest service center.
POSSIBLE CAUSES OF THE ABOVE PROBLEMS
Condition 1
The following sounds are normal during operation:
A low humming sound indicating that the unit is operating.
A soft clicking sound when the compressor turns on and off.
A flowing sound due to circulation of the refrigerant when the
compressor is turned on.
A splashing sound indicating condensation in the condenser coil.
If you hear other noises, please consult your nearest servicenter.
Condition 2
The main power cord is not plugged in.
The internal fuse has blown.
The main circuit breaker has tripped.
Remote control batteries are weak.
BEFORE CALLING FOR SERVICE
Condition 3
The room is too big for the units cooling capacity.
The ventilation lever is set to OPEN.
The air circulation is impeded by curtains or furniture.
After 15 minutes of operation, it is normal for the temperature
difference between intake and outlet air to be more than 14.4°F for cooling.
If the unit is too noisy during operation.
If the unit does not operate.
If the unit does not cool properly.
Condition 4
Humidity is high.
Condensed water is overflowing.
To rectify the problem, mount an optional drain pan to the
unit.
Condition 5
The unit is tilted inward. To rectify this, tilt the unit slightly outward.
Mount the optional drain pan if you prefer.
The drain pan may be blocked.
If the trouble persists after you have checked all of these, call your authorized Panasonic dealer or servicenter. Service information can be obtained 24 hours/day by calling: 1-800-211-PANA (7262) To expedite the repair of your air conditioner:
Please have your proof of purchase.
List all symptoms the unit is exhibiting.
If water drips off the rear of the unit.
If water drips inside the room.
Panasonic Consumer Electronics Company, Division of Matsushita Electric Corporation of America
One Panasonic Way Secaucus, New Jersey 07094
Panasonic Sales Company, Division of Matsushita Electric of Puerto Rico, Inc.,
Ave. 65 de Infanteria, Km. 9.5 San Gabriel Industrial Park Carolina, Puerto Rico 00985
Quasar Room Air Conditioner
Limited Warranty
Panasonic Consumer Electronics Company or Panasonic Sales Company (collectively referred to as “the Warrantor”) will repair this product with new or refurbished parts in case of defects in material or workmanship, free of charge, in the USA or Puerto Rico in accordance to the following (All time periods start from the date of the original purchase).
SEALED REFRIGERATING SYSTEM (compressor and interconnecting tube): FIVE (5) YEARS - PARTS AND LABOR
ALL OTHER COMPONENTS: ONE (1) YEAR - PARTS AND LABOR
In-home service in the USA can be obtained during the warranty period by contacting a Panasonic Service Company (PASC) Factory Servicenter listed in the Servicenter Directory. Or call toll free, 1-800-211-PANA(7262), to locate a PASC authorized Servicenter. In-home service in Puerto Rico can be obtained during the warranty period by calling the Panasonic Sales Company telephone number listed in the Servicenter Directory.
Note: If the unit is installed at the other than normal window height and/or has been
custom-installed (e.g., through the wall), the customer is responsible for removing the unit from its installation prior to the performance of in-home service.
This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of the original purchase is required for service and parts replacement under this warranty.
This warranty only covers failures due to defects in materials and workmanship and does not cover normal wear or cosmetic damage. The warranty does not cover damages which occur in shipment, or failures which are caused by products not supplied by the warrantor, or failures which result from accident, misuse, abuse, neglect, mishandling, misapplication, faulty installation, maladjustment of customer controls, improper maintenance, alteration, modification, power line surge, lightning damage, improper voltage supply, commercial use such as hotel, office, restaurant, or other business or rental use of the product, or service by anyone other than a PASC Factory Servicenter or a PASC authorized Servicenter, or damage that is attributable to acts of God.
LIMITS AND EXCLUSIONS
There are no express warranties except as listed above. THE WARRANTOR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY, ARE LIMITED TO THE APPLICABLE WARRANTY PERIOD SET FORTH ABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. If a problem with this product develops during or after the warranty period, you may contact your dealer or Servicenter. If the problem is not handled to your satisfaction, then write to the Consumer Affairs Department at the company address indicated above.
SERVICE CALLS WHICH DO NOT INVOLVE DEFECTIVE MATERIALS OR WORKMANSHIP AS DETERMINED BY THE WARRANTOR, IN ITS SOLE DISCRETION, ARE NOT COVERED. COSTS OF SUCH SERVICE CALLS ARE THE RESPONSIBILITY OF THE PURCHASER.
[For assistance, please call: 1-800-211-PANA (7262) or send e-mail to consumerproducts@panasonic.com]