Figure 99: Back Focus Adjustment ........................................................................................................ 110
Figure 100: Typical Spring Clamp Terminal Block ................................................................................. 112
Figure 101: Connecting a Wire to a Terminal Block .............................................................................. 112
v
Revision History
Version
Date
Author
Comments
A
Oct. 2013
Jonathan Herman
Merged CF-3211 and CF-4221 User and
Installation Guides. Updated look and feel.
B-E
Nov.-Dec. 2013
Alan Singer
General editing and formatting.
F
Mar. 2014
Alan Singer
Added Revision History. Updated DNA
screenshots in section 6. Updated look and
feel.
G
Jun. 19, 2014
Alan Singer
Corrected image sensor and sensitivity
specifications.
Revision History
vi
Document Information
Note:
This document is intended for use by technical users who have a basic understanding of
CCTV camera/video equipment and LAN/WAN network connections.
Warning:
Installation must follow safety, standards, and electrical codes as well as the laws that
apply where the units are being installed.
1Document Information
Document Scope and Purpose
The purpose of this document is to provide instructions and installation procedures for physically
connecting the Quasar CF-3211 and CF-4221 cameras. After completing the physical installation,
additional setup and configurations may be required before video analysis and detection can
commence.
Proprietary Rights and Non-Disclosure
This manual is delivered subject to the following restrictions and conditions:
This document contains proprietary information belonging to DVTEL, Inc. This information
is supplied solely for the purpose of assisting explicitly the licensee of the DVTEL units.
No part of this document contents may be used for any other purpose, disclosed to any
third party or reproduced by any means, electronic or mechanical, without the express
prior written permission of DVTEL, Inc.
Trademarks and Copyrights
This manual and its contents herein are owned by DVTEL, Inc. All rights reserved.
DVTEL, the DVTEL logo, Quasar CF-3211 and CF-4221 are trademarks of DVTEL, Inc.
Products and trademarks mentioned herein are for identification purposes only and may be
registered trademarks of their respective companies.
DVTEL, Inc. makes no representations whatsoever about any other products or trademarks
mentioned in the manual.
Quasar CF-3211/CF-4221 User and Installation Guide
A Warning is a precautionary message that indicates a procedure or condition where
there are potential hazards of personal injury or death.
A Caution is a precautionary message that indicates a procedure or condition where
there are potential hazards of permanent damage to the equipment and or loss of data.
A Note is useful information to prevent problems, help with successful installation, or to
provide additional understanding of the products and installation.
A Tip is information and best practices that are useful or provide some benefit for
installation and use of DVTEL products.
Disclaimer
Users of DVTEL products accept full responsibility for ensuring the suitability and considering the
role of the product detection capabilities and their limitation as they apply to their unique site
requirements.
DVTEL, Inc. and its agents make no guarantees or warranties to the suitability for the users’ intended
use. DVTEL, Inc. accepts no responsibility for improper use or incomplete security and safety
measures.
Failure in part or in whole of the installer, owner, or user in any way to follow the prescribed
procedures or to heed WARNINGS and CAUTIONS shall absolve DVTEL, Inc. and its agents from any
resulting liability.
Specifications and information in this guide are subject to change without notice.
Document Conventions
WARNING and CAUTION notes are distributed throughout this document, whenever applicable, to
alert you of potentially hazardous situations. These may be hazards associated with a task or a
procedure you are carrying out or are about to carry out.
The following document conventions are used throughout this manual:
General Cautions and Warnings
This section contains information that indicates a procedure or condition where there are potential
hazards. These may be hazards associated with a task or procedure a user is carrying out or about to
carry out. WARNINGS and CAUTIONS are distributed throughout this document, whenever
applicable, to alert the user of potentially hazardous situations.
SAVE ALL SAFETY AND OPERATING INSTRUCTIONS FOR FUTURE USE.
Although the unit is designed and manufactured in compliance with all applicable safety standards,
certain hazards are present during the installation of this equipment.
To help ensure safety and to help reduce risk of injury or damage, observe the following:
viii
Warning:
1. The camera cover is an essential part of the product. Do not open or remove it.
2. Never operate the camera without the cover in place. Operating the camera
without the cover poses a risk of fire and shock hazards.
3. Do not disassemble the camera or remove screws. There are no user
serviceable parts inside the unit.
4. Only qualified trained personnel should service and repair this equipment.
5. Observe local codes and laws and ensure that installation and operation are in
accordance with fire, security and safety standards.
Electrical Safety Notice and Warnings
Warning:
1. Read the installation instructions before you connect the unit to a power source.
2. Electrical safety should always be observed. All electrical connections must be
performed by a certified electrician.
3. Use the supplied power supply and protect against static electricity,
ground faults and power surges.
4. The unit uses a three-wire power cord to make sure that the product is properly
grounded when in use. If the intended power outlet does not support three
prongs, one of which is a ground, contact an electrician to install the appropriate
outlet. NEVER remove or otherwise attempt to bypass the ground pin of the
power cord. Do not operate the unit in the absence of a suitably installed ground
conductor.
5. If you use an extension cord with this system, make sure that the total ampere
rating on the products plugged into the extension cord does not exceed the
extension cord ampere rating.
6. To avoid possible shock hazards or damaging the unit, assure that the positive
and negative of the power leads are properly connected to the terminal block
connector before plugging it into the unit or turning on the power source.
7. In the following situations, the electric power should be turned off immediately
and appropriate repairs, replacements or remedies should be taken if:
The power line or plug is damaged, frayed or shows heavy wear.
The unit has been physically crushed or deformed.
The unit has been exposed to water.
The unit has been exposed to, or shows signs of damage from, fire,
intense heat, heavy smoke, fumes, or vapors.
Electrical connections of the unit become abnormally hot or generate
smoke.
The unit has been dropped, damaged or shows signs of loose internal
parts.
The unit does not operate properly.
Document Information
ix
Quasar CF-3211/CF-4221 User and Installation Guide
Caution:
To avoid damage from overheating or unit failure, assure that there is sufficient
temperature regulation to support the unit’s requirements (cooling/heating). Operating
temperature should be kept in the range 0° to 50°C (32° to 122°F), with no more than
90% relative humidity (non-condensing).
Minimizing EMI and RFI
When wires run for a significant distance in an electromagnetic field, electromagnetic interference
(EMI) can occur. Strong EMI (e.g. lightning or radio transmitters) can destroy the units and can pose
an electrical hazard by conducting power through lines and into the system. Poor quality or worn
wiring can result in radio frequency interference (RFI). To minimize the effects of EMI and RFI,
consult your reseller.
Site Preparation
There are several requirements that should be properly addressed prior to installation at the site.
The following specifications are requirements for proper installation and operation of the unit:
Ambient Environment Conditions: Avoid positioning the unit near heaters or heating
system outputs. Avoid exposure to direct sunlight. Use proper maintenance to ensure that
the unit is free from dust, dirt, smoke, particles, chemicals, water or water condensation,
and exposure to EMI.
Accessibility: The location used should allow easy access to unit connections and cables.
Safety: Cables and electrical cords should be routed in a manner that prevents safety
hazards, such as from tripping, wire fraying, overheating, etc. Ensure that nothing rests on
the unit’s cables or power cords.
Ample Air Circulation: Leave enough space around the unit to allow free air circulation.
Cabling Considerations: Units should be placed in locations that are optimal for
the type of video cabling used between the unit and the cameras and external
devices. Using a cable longer than the manufacturer’s specifications for optimal
video signal may result in degradation of color and video parameters.
Physical Security: The unit provides threat detection for physical security systems. In order
to ensure that the unit cannot be disabled or tampered with, the system should be installed
with security measures regarding physical access by trusted and un-trusted parties.
Network Security: The unit transmits over IP to security personnel for video surveillance.
Proper network security measures should be in place to assure networks remain operating
and free from malicious interference. The unit is intended for installation on the backbone
of a trusted network.
Electrostatic Safeguards: The unit as well as other equipment connected to it (relay
outputs, alarm inputs, racks, carpeting, etc.) shall be properly grounded to prevent
electrostatic discharge.
The physical installation of the unit is the first phase of making the unit operational in a security
plan. The goal is to physically place the unit, connect it to other devices in the system, and to
establish network connectivity.
x
Overview
Caution:
If you are using DVTel Latitude, we recommend that you configure the camera’s settings
via the AdminCenter. This is because the camera’s web-based interface might be
overwritten by Latitude settings. Refer to the Latitude online help for information
regarding configuring camera settings.
Progressive scan CMOS
sensor
H.264 and MJPEG
compression
Motion selection with Region Of
Interest masking
Privacy masks
WDR and ATW
3DNR image noise reduction
Day/Night (IR Cut Filter)
Micro SD recording
support
BNC analog output
ONVIF support
Analog video output
Supports PoE/12VDC/24VAC
Edge motion detection
Multiple users
RTSP support
Security IP restricted
access allow/deny list
Built-in web application/
web server
Group permissions
HTTP streaming MPEG
SNMP v1/v2/v3 SNMP
Traps
Per-user permissions
E-mail SMTP alarm
notification (up to 2
emails)
FTP upload (up to 2
locations)
Dual HTTP notification server
support (up to 2 servers)
Detection event-driven
alarms
Alarm input driven events
Relay output actions on alarm
Send images on alarm to
e-mail
Upload alarm images to
FTP
Record snapshots to SD card on
alarm
Sequential snapshot
numbering
UPnP support
Historical motion detection levels
detected and recorded at frame
levels.
Tampering detection and
notification
Two encoder streams
available
Low lux
Note:
MJPEG is not supported by Latitude.
2 Overview
The Quasar CF-3211 and CF-4221 series fixed cameras are HD 720p and Full HD 1080p devices,
respectively. These cameras provide real-time, H.264 multi-streaming video and the highest quality
image. With its compact, sophisticated and aesthetic mechanical design, the lightweight DVTEL
CF-3211 and CF-4221 cameras are simple and easy to install.
2.1 Features
Following are key features of the CF-3211/CF-4221 camera:
1
Quasar CF-3211/CF-4221 User and Installation Guide
Full HD Multiple Streaming
Camera
Back focus adjuster
Quick-start guide
CD
(Bundled software and
documentation)
Item
Designation
Description
1
Lens
Camera lens
2
Focus fixing knob
To set the focus, loosen and tighten by hand the adjustment
knob until the optimum focus is obtained.
3
Zoom fixing knob
To set the zoom, loosen and tighten by hand the adjustment
knob until the optimum zoom is obtained.
2.2 Package Contents
Before proceeding, please check that the box contains the items listed here. If any item is missing or
has defects, do not install or operate the product and contact your dealer for assistance.
Figure 1: Package Contents
2.3 Typical CF-3211/CF-4221 Camera
The figure below shows a typical CF-3211/CF-4221 series camera.
Figure 2: CF-3211/CF-4221 Camera – Front View
Table 1: CF-3211 Camera Adjustment Locations
2
Introduction to the CF-3211 and CF-4221 Fixed IP Cameras
3 Introduction to the CF-3211 and CF-4221 Fixed IP Cameras
This chapter provides the camera dimensions for reference before installation. Each connector
located inside the camera’s housing is also identified. See Figure 4 and Table 2.
Related Links
CF-3211/CF-4221 Camera Dimensions
Camera Connectors
Appendix A.1: Technical Specifications
3.1 CF-3211/CF-4221 Camera Dimensions
The mechanical dimensions of a CF-3211/CF-4221 Fixed IP Camera are shown below.
Figure 3: CF-3211/CF-4221 Camera Dimensions
3.2 Camera Connections
Figure 4 shows the various connectors and reset button contained within the housing of the CF-3211
and CF-4221 cameras. The connectors, pin numbers and signal definitions related to each pin are
listed in Table 1.
Figure 4: CF-3211/CF-4221 Camera Input/Output Connections
3
Quasar CF-3211/CF-4221 User and Installation Guide
ID
Connector Name
Pin No./ Connector Type
Definition
Description
1
Line Out
Audio out
2-way audio
transmission
2
Line In/Mic In
Audio in
3
PoE Network
RJ45, Network LEDs
10/100 Mbps
Ethernet/PoE
Power over Ethernet
4
Video
BNC
Analog video
For video output
5
SD
microSD card slot
For video and snapshots
storage (card not
included)
6
DC 12V/AC 24V
1 – Power (+)
2 – Reserved
3 – GND (-)
12V DC
Power supply
connection indication
(green LED)
1- Power (+)
2- Earth GND
3- Power (-)
24V AC
7
to
9
I/O 1 to 7
1 - Output (+)
2 - Output (-)
Alarm output
7-terminal connection
block
3 - Input (+)
4 - Input (-)
Alarm input
5 - GND
Grounding
6 - D (-)
7 - D (+)
Reserved
Do NOT connect
10
Auto Iris
DC iris lens connector
DC iris port
11
PWR
N/A
Power LED
Power indication
12
RESET
N/A
Reset
Restores factory default
settings
Table 2: CF-3211/CF-4221 Camera Connector Panel Description
4
System Requirements
Item
Minimum System Requirement
Personal Computer
Intel® Pentium®M, 2.16 GHz or Intel® CoreTM2 Duo, 2.0 GHz
2GB RAM or more
Operating System
Windows, Windows XP, Windows 7
Web Browser
Microsoft Internet Explorer 7, 8, or 9
Network Card
10Base-T (10 Mbps) or 100Base-TX (100 Mbps) operation
Viewer
ActiveX control plug-in for Microsoft IE
4 System Requirements
To access the CF-3211/CF-4221 fixed IP camera via a web browser, ensure that your PC has the
proper network connection and meets the system requirements described below.
Table 3: System Requirements
5
Quasar CF-3211/CF-4221 User and Installation Guide
6
Installation
Power and Ethernet
Cable Connection
Initial Camera Configuration
Mounting Instructions
Adjusting and Framing-
Up the Camera View
Note:
An Ethernet crossover cable can be used when connecting the CF-3211/CF-4221
camera directly to the PC.
RJ45
Connector
LED
Description
Green
Link Light - indicates a stable network connection
Yellow
Activity Light - flashes to indicate network activity
5 Installation
Follow the instructions below for indoor installation of the Quasar CF-3211/CF-4221 series camera.
5.1 Indoor Installation
Read the instructions provided in this chapter thoroughly before installing the CF-3211/CF-4221
camera. The following points are additional considerations for indoor installation:
There must be a fuse or circuit breaker at the starting point of the electrical wiring
infrastructure.
For indoor installations, such as industrial applications, the CF-3211/CF-4221 camera must
be protected from hostile external elements (e.g. corrosive environment, metallic dust,
extreme temperatures, soot, moisture, over spray, etc.)
Do not place the CF-3211/CF-4221 camera on or near radiators and heat sources.
All electrical work must be performed in accordance with local regulatory requirements.
Related Links
5.2 Power and Ethernet Cable Connection
Power Connection
Make sure the camera’s power cable is properly connected. Refer to Table 1: CF-3211/CF-4221
Camera Connector Designations. If using Power over Ethernet (PoE), make sure Power Sourcing
Equipment (PSE) is available on the connected network. All electrical work must be performed in
accordance with local regulatory requirements.
Ethernet Cable Connection
A Cat 5 Ethernet cable is recommended for network connection. For best transmission quality, the
cable length should not exceed 100 meters (328 feet). Connect one end of the Ethernet cable to the
CF-3211/CF-4221 camera and the other end of the cable to the network switch or PC.
Check the status of the link indicator and activity indicator LEDs. If the LEDs are unlit, check the LAN
connection.
Table 4: Network Port LED Indications
7
Quasar CF-3211/CF-4221 User and Installation Guide
Note:
The camera lens is sold separately and should be selected to match the needs of the
scene and to optimize the use of the camera capabilities. See Mounting and Lens
Accessories.
Note:
A smaller focal length number allows a wider field of view. A larger focal number
represents a narrower and deeper field of view.
Tip:
Do not touch the sensor or allow dust to accumulate in the lens-mount.
C to CS Mount Adapter
Completion
5.3Lens Mounting
Before installing your camera, install the camera lens.
Auto Iris vs. DC lens
A manual iris lens is best for use in scenes where illumination never changes, such as a persistently
lit store or office. Auto iris is better suited for scenes where the lighting may vary throughout the
day and night.
The trade-off is in the amount of detail and depth of view vs. the width of view. For example a 2.8 or
4 mm lens might be sufficient for indoor warehouse and office and an 8mm might be better suited
for outdoor perimeters.
After you select your lenses and see the amount of detail provided consider your security
surveillance coverage, camera locations and any additional needs that may be discovered. Consult
your DVTEL rep if you have any questions.
To mount a lens on the CF-3211/CF-4221 camera
1. Remove the plastic insert covering the threaded camera lens-mount.
2. If you are using a C-mount lens, screw a 5mm adapter ring into the C-Mount to
convert it to a CS-Mount (see Figures below).
3. Align the lens threads into the lens-mount and screw on the lens.
8
4. If your lens has a DC auto iris, plug the auto-iris cable from the motorized lens
Tip:
If there are problems focusing, it might be necessary to make a back focus adjustment.
Note:
DNA is an enhanced software alternative to Device Search. Either of these
programs may be used. They are supplied on the included CD.
assembly into the AUTO IRIS port of the camera.
Figure 5: Auto Iris Port Connection
5.4 Initial Camera Configuration
To perform the initial camera configuration:
Installation
1. Unpack the camera and remove the protective cover.
2. Remove the PE cloth sheet and lens cap. Attach the dome cover to the body.
3. Connect one end of the Cat 5 Ethernet cable to the Ethernet port of the camera and the
RJ45 connector at other end to the Power Sourcing Equipment (PSE) device, such as a
switch.
4. Verify that the RJ45 connector LEDs illuminate green (indicating a stable network
connection) and flashing yellow (to indicate network activity).
5. Do one of the following:
Copy and run the dna.exe from the included CD.
From the Latitude Sidebar, run the Unified Configurator by selecting Applications >
Device Configuration Tool and then, on the Unified Configurator screen, click DVTEL
HD Series.
1. Mark the unit requiring IP assignment.
Figure 6: Discovered IP Devices
9
Quasar CF-3211/CF-4221 User and Installation Guide
Note:
The camera can be connected to a PC for bench installation via an Ethernet crosscable.
Note:
The camera default IP Address and the subnet mask IP Address are automatically
supplied by the DHCP server.
Tip:
A camera setup adapter, such as Veracity Pinpoint, can be used to connect a laptop
directly to the camera when using PoE.
Caution:
The CF series indoor camera must be kept in a clean and dry indoor environment or in a
protective camera housing. Operating temperature should be maintained within -10°C
to 50°C (14° to 122°F). Operating humidity is 10% to 90% (non-condensing). The camera
should be kept dry, free from water condensation, dust, dirt, and smoke.
2. Right-click on the mouse and select the assigned IP or press the Assign IP button to open the
DNA Assign IP screen.
3. In the dialog box that is displayed, enter values for the IP Address, Gateway and Netmask.
4. Click Update and wait for OK status to be displayed.
Figure 7: Assign IP Dialog Box
5. Disconnect the Ethernet cable. The camera is ready for deployment (mounting) in a site
installation.
5.5 Mounting Instructions
The following are mounting instructions for the DVTEL CF-3211 and CF-4221 Fixed IP cameras.
10
To mount the camera, follow one of these procedures:
For indoor installations without a housing:
a. On the ceiling/wall/flat surface, install a security camera wall mount bracket stand
that is sturdy enough to hold the camera in a fixed position for the field of view
required.
b. Screw the bracket/stand to the mounting socket on the bottom of the camera.
c. Connect the cables and wiring to the camera. See Figure 4: CF-3211/CF-4221 Camera
Input/Output Connections and Table 2.
For indoor/outdoor installations using a typical protective camera housing:
a. Thread the wires through any of the infrastructure and brackets (e.g. pole
bracket/corner bracket/etc.) as needed as well as through the wall bracket arm.
b. Bolt the wall bracket (arm) to the prepared surface.
c. Loosen the screws or unlatch the camera housing lid, open the housing and loosen
the plastic cable glands (cable fittings).
d. Thread the cables through the cable glands into the camera housing.
Installation
Figure 8: Cable Gland
e. Attach the camera housing to the wall bracket (arm) using the provided screws and
wrench.
f. Remove the housing plate (base for camera) and using the provided camera mount
screw, thread the screw through the plate into the camera’s bottom mounting
socket.
g. Put the camera mounted on the base plate back in the housing. (We will adjust
forward positioning when we adjust the lens.)
h. For housings with internal blowers and heaters, connect the wiring to the camera
housing terminals (power input) according to the manufacturer’s instructions for
heaters (heater output) and fans (blower output) that the camera housing features.
Connect any ground (GND) to the camera housing ground connection.
i. Connect the cables and wiring to the camera. See Figure 4: CF-3211/CF-4221
Camera Input/Output Connections and Table 2.
11
Quasar CF-3211/CF-4221 User and Installation Guide
Note:
For outdoor installation, the camera must be installed in a protective
housing such as a DVTEL CF-X201-00 camera housing. See Figure 9.
Figure 9: DVTEL CF-X201-00 Camera Housing
12
Using the DNA Utility to Search and Access the Camera
Note:
DNA is an enhanced software alternative to Device Search. Either of these programs may
be used.
Caution:
Users who have previously installed the DVTEL Web Player (DCViewer) on the PC should
delete the existing DCViewer from the PC before accessing the camera. For information
on how to uninstall and clear Temporary Internet Files, see Appendix A5: Deleting the
Existing DCViewer.
6 Using the DNA Utility to Search and Access the Camera
6.1 Introduction
The DVTEL Network Assistant (DNA) is a user-friendly utility that is designed to easily discover and
configure DVTEL edge devices on a network.
The DNA tool has a simple user interface and does not require any installation. The software is
provided as a single, standalone executable. It runs on any PC.
DNA provides a central location for listing all the DVTEL CM, CF and CP camera models accessible
over the network. Once listed, each camera can be right-clicked to access and change the network
settings.
If the network settings are changed for some reason, a new search will relist the units. The units may
then be configured via the web interface.
If DVTEL Latitude is being used, configure the unit with a static IP address rather than with DHCP.
This ensures that the IP address will not automatically change in the future and interfere with
configurations and communication.
The camera must be made accessible for the network’s addressing.
To install DVTEL Web Player (DCViewer) software online:
Upon initial connection to the camera, a prompt to install the DVTEL Web Player (DCViewer)
appears. If the web browser does not allow DVTEL Web Player to install, check the Internet security
settings or ActiveX controls and plug-in settings to continue the process. See Internet Security
Settings.
Follow the instructions below to start using the DNA application.
6.2 Quick Start
1. Install and run the DNA application on a computer connected to the network. The
software is an .exe file supplied in a zip file together with an Online Help file (.chm).
2. Extract both files from the zip file, and place them together in a new directory. Both files
should have the same name, but different extensions (.exe and .chm).
3. Upon launching the tool, DNA automatically discovers all devices on the network. The
initial launch creates a default .ini file (dna.ini).
4. In the event that there are devices that are not authenticated, click Login and enter login
credentials for the devices.
13
Quasar CF-3211/CF-4221 User and Installation Guide
5. If there are devices located on a separate VLAN, the devices must be added manually.
Click Add Device Manually from the Operational Toolbar and add the devices.
6.3 Main Screen
The DNA main screen contains four sections, as seen in the following figure:
Figure 10: DNA Main Screen
6.4 Navigation Bar
The callouts on the screen are explained below:
1. Navigation Bar: Located at the top of the screen. Includes tabs and dropdown menus to
perform actions.
2. Operational Toolbar: Located below the Navigation Bar. Used to refresh discovered
units, filter connected devices for easy operation, and to add a device manually.
3. Discover List: Occupies the center of the screen. Displays a list of discovered devices
with partial device information.
4. Status Bar: Located at the bottom of the screen. Displays current device status, including
scanning time, status, and the number of discovered units.
The Navigation Bar contains tabs for all the actions needed to configure and manage attached
devices. If no devices have been discovered, all the tabs are gray (disabled).
After a device has been discovered, the tabs for functions which it supports are enabled and colored,
as seen in the following Figure:
14
Using the DNA Utility to Search and Access the Camera
Note:
DNA is an alternative software to Device Search. Either of these programs may
be used.
To define the device on which to perform an action, the user must select the device from the
Discover List. The user can select more than one device, in which case the action will be done on all
selected devices.
6.5 Context Menu
All functions on the Navigation Bar are also accessible from the context menu, which is available
when right-clicking on a device within the Discover List, as seen in the following figure:
Figure 11: Context Menu
Assign IP Tab
The Assign IP tab or context menu option is used to automatically assign the IP address of the
selected device(s). This function can be used for automatic batch network configuration.
The Assign IP tab or context menu option is used to automatically assign the IP address of the
selected device(s). This function can be used for automatic batch network configuration. The Assign IP tab or context menu option is grayed if a device has not been selected.
Selecting this tab or option opens the Assign IP window, which displays a list of devices which need
to be updated, as shown in the illustration below. The Assign IP window is divided into two areas
See section 6.6 for more details.
6.6 Configuring Communication Settings on the Quasar Camera
To configure communication settings on the camera:
1. Connect the camera to the network on the same VLAN/LAN as the workstation.
2. If the network supports the default, open DNA utility by running dna.exe which can be
found in the DNA Utility folder in the supplied CD, , or click the DNA icon .
3. In the DNA application, click the DNA button.
4. If the Windows Firewall is enabled, a security alert window pops up.
15
Quasar CF-3211/CF-4221 User and Installation Guide
5. To continue, click Allow Access. Latitude users should consult the Latitude Installation
Instructions on disabling the Windows Firewall.
Figure 12: Windows Firewall Screen
6. Click Assign IP. All the discovered IP devices will be listed in the page, as shown in the figure
below. The camera’s default IP Address is automatically supplied by the DHCP server.
Figure 13: Discovered IP Devices
7. Right-click the camera whose network property is to be changed. From the menu that
opens, select Network Setup. The Network Setup dialog is displayed.
Figure 14: DNA Assign IP – Use DHCP Dialog Box
16
Using the DNA Utility to Search and Access the Camera
Tip:
Record the camera’s MAC address for future reference.
Note:
ID and password are case-sensitive.
Note:
It is strongly advised that administrator’s password be altered for
security reasons.
8. To access DNA, do one of the following:
a) For DHCP (not supported by Latitude):
i. Select Use DHCP. Do not use for Latitude.
ii. Click Update and wait for status.
b) For Static IP (recommended for Latitude users):
Figure 15: DNA Assign IP – Static IP Dialog Box
i. Do not select the Use DHCP checkbox. This is recommended for security
purposes and for and Latitude users. In the IP Address, Gateway, and Netmask,
enter the respective LAN/VLAN (optional DNS) values.
ii. Click Update and wait for OK status to be displayed.
9. Right-click and select Browse to directly access the camera via a web browser. The default
web browser opens and requests access to the camera IP address.
10. When the web browser contacts the camera IP, do the following:
a) Login using the default user name Admin and password 1234.
17
Quasar CF-3211/CF-4221 User and Installation Guide
Note:
If the password is changed and DVTEL Latitude AdminCenter Discovery feature is
in use, deselect all other proprietary types. Select DVTEL HD Series so that the
new password can be configured in the Discovery tab settings.
b) If the Information Bar (just below the URL bar) prompts for permission to install
the ActiveX Control for displaying video in the browser (see the figure below), rightclick on the Information Bar. Select Install ActiveX Control to allow the installation.
Figure 16: Installing the ActiveX Control
If a security warning window prompt appears, click Install.
Figure 17: Security Window
11. If the wizard appears for installing the component application DCViewer, follow the
instructions to complete the installation.
Additionally, users can change the camera’s network property (either DHCP or Static IP) directly in
the device finding list. Refer to the following section for changing the camera’s network property.
18
Using the DNA Utility to Search and Access the Camera
Tip:
To view greater image detail for more accurate high-definition focusing, on
the web interface Home page, click the Full Screen button and use the
full screen view to check the focus.
Note:
Best focusing results can be achieved when the lens iris is fully open (such as
at night in low light). This prevents loss of sharpness if light levels are
reduced at night.
6.7 Adjusting and Framing-Up the Camera View
After the camera is connected to the network and running, it is necessary to frame-up the scene and
adjust the camera settings to optimize the picture for the individual scenes. If Latitude is being used,
consider scheduling different settings for changing ambient conditions throughout the day, week,
month or seasons.
To adjust and frame-up the camera view:
1. In the DNA application, click DNA.
2. In the results, click to select the camera.
3. Right-click to open the shortcut menu, and select Browse, or enter the camera’s IP
address in your Internet browser’s URL address bar.
4. When the Internet browser connects to the camera and prompts for login, do the
following:
a) Log in using the default user name Admin and password 1234. If the password has
previously been changed, use the new password.
b) Allow the ActiveX to download and choose to install the DVTEL Web Player
(DCViewer).
To achieve this during the day, in the web interface, go to the Camera>Exposure screen
and select from the Exposure Setting menu Auto Shutter mode. Save changes and
complete the focusing steps. When finished, restore your exposure settings as needed.
19
Loading...
+ 95 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.