Quartech 9113-1 Series Product Manual

Product Manual
Model 9113-1-X
Ethernet Bridge II
for Ultra 3000 Servo
Quartech Corporation
15923 Angelo Drive
Macomb Township, Michigan 48042-4050
Phone: (586) 781-0373 FAX: (586) 781-0378
PM9113-1-X Revision 0
The product described in this document can have a variety of uses, the user and those responsible for applying this equipment must satisfy themselves as to the acceptability of each application and the use of the unit. Under no circumstances will QUARTECH CORPORATION be responsible or liable for any damage, including indirect or consequential losses resulting from the use, misuse, or application of the unit.
The text, illustrations, charts, and examples included in this document are intended solely to help explain applications of the product. Due to the many variables associated with specific uses or applications, QUARTECH CORPORATION cannot assume responsibility or liability for actual use based upon the data provided in this document.
No patent liability is assumed by QUARTECH CORPORATION with respect to the use of circuits, information, equipment, or software described in this document.
This document is subject to change without notice.
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
The Model 9113 Ethernet Bridge allows an Allen-Bradley PLC such as a MicroLogix or CompactLogix to monitor and control an Ultra 3000 Servo Drive over an ethernet connection. The 9113 connects to the Ultra 3000 CN3 port using a cable provided with the unit and to the PLC v ia a 10/100 auto sensing ethernet port.
The PLC will access the 9113 as though it were another PLC using File/Element addressing. A pre-defined map exists within the 9113 that associates Ultra 3000 Host Command Reference parameters to File/Element numbers. The 9113 can perform scaling that allows your PLC program to work in scaled values such as inches or RPMs.
The 9113-1-1 allows Allen Bradley Ultraware software to access Ultra 3000 drives over an ethernet network when used in conjunction with the Quartech Ethernet Gateway program. The Ethernet Gateway program creates a virtual serial port that Ultraware will connect to. Your computer does not need to have an actual serial communication port. The gateway uses a node address to IP address mapping table to determine which drive to access on the ethernet network.
Page 2
Free utility suite is available that includes an IP address server, a firmware update utility, an Ultra parameter mapping utility, and the ethernet gateway utility.. Shown below is the simplest application which does not require an ethernet hub or switch. The PLC will access drive parameters using the Message Instruction.
9113 Web Utilities
All configuration to the 9113-1-X is accomplished by the built in Web Utilities server accessed using your internet browser.
The Ultra drive must have its serial communication port configured as follows:
38400 Baud, 8 Data, No Parity, 1 Stop
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
Page 3
Theory of Operation
The 9113 allows a PLC to read and write parameters within the Ultra 3000 drive using the Message Instruction. The parameters in the Ultra 3000 are mapped to File/Element numbers so the PLC accesses the Ultra parameters as though they were File/Elements in a peer PLC
For the PLC to read or write File/Elements it must first establish a TCP connection to the 9113. Next the PLC must request a session identification number from the 9113. The PLC is then ready to read and write File/Elements as instructed by the PLC program. The TCP and session connections are transparent to the user and PLC program but do have implications that require understanding. Once a session is established between the 9113 and PLC it can remain indefinitely prov iding both devices remain wired, powered, and active.
Once a session is established the 9113 expects the PLC to make regular read/write requests. If a request is not received for a thirty seconds then the session will be cancelled and the TCP connection will be closed. The mode LED will be flashing green when a session is active and amber when no session is active..
When using a MicroLogix or SLC 500 Processor use the 500CPU Read and 500CPU Write commands. W hen using a CompactLogic Processor use the SLC Typed Read and SLC Typed Write commands.
9113 Utility software is available free of charge at the
Quartech Corporation web site.
Also available is the latest version of this product manual
plus other related manuals and documents.
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
Page 4
Multiple Axis:
The 9113 provides a bridge to a single drive When an application requires multiple drives to be controlled then each drive will have an associated 9113 with a unique IP address. An ethernet hub or switch will be required to connect the devices.
Each 9113 in a network must have a unique IP address. The node address of the Ultra 3000 has no significance in the network but must match the node set in the 9113. The 9113 is configured by the factory to access Ultra node zero which is the default for a new Ultra 3000 drive. The node used by the 9113 can be modified using the Web Utilities..
Address Mapping Utility
This utility will find the File/Element number associated with an Ultra 3000 parameter you select. The utility will run along with RSLogix and will remain on top unless minimized. This allows you to quickly select a parameter, copy the associated File/Element number to the Windows clipboard then paste the number into the RSLogix Message Instruction setup dialog.
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
Ethernet Cables:
The 9113 operates with standard ethernet cables available from many sources. The examples below are consistent with the TIA/EIA 568-B color code standard.
Straight Through Cable Crossover Cable
Device to Hub / Switch Device to Device
Page 5
Ethernet Cable Notes:
- Straight through cables have identical color coded ends
- Crossover cables have different color coded ends.
- Straight through cables are used as a patch cord between a device and a hub or switche.
- Crossover cables are used to connect two devices directly without a hub or switch.
- Odd numbered pins are always striped, even numbered pins are always solid colored.
- The solid brown wire is always pin 8.
Serial Port Cables
The serial communication port of the 9113 uses RS-232 signal levels. A standard six pin circular mini-DIN plug must be used on the 9113
end of all communication cables. A two foot long cable is provided with the 9113 for connection between the 9113 and Ultra 3000 serial ports.
Pin 1 - No Connection Pin 2 - Transmit Data Pin 3 - Receive Data Pin 4 - Request-To-Send Pin 5 - Clear-To-Send Pin 6 - Signal Common
Front view of plug
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
2180 Cable - 9113 to Ultra 3000
(Supplied with 9113)
Ultra 3000 Communication Parameters: 38400 Baud, 8 Data Bits, No Parity, One Stop Bit
2182 Cable - 9113 to 9120 Two Port Multiplexer
Page 6
9 Pin Male D-Type
Specifications:
Electrical: 24 VDC, ±5%, @ 200 ma Temperature: 0Ec to +60Ec Operational, -20Ec to +70Ec Storage Humidity: 10% to 95%, Non-condensing, Operational or storage Vibration/Shock: 0.5mm displacement (X,Y,Z axis), 10-55Hz, 30G shock Weight: approximately ½ pound
9 Pin Female D-Type
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
9113 Hardware
Page 7
Power Terminal:
Power to the 9113 is supplied through a three position removable compression terminal block. The 9113 requires 24 volt, two hundred milliamp direct current power. An earth ground connection is also required and provided through the terminal block. Do not plug or unplug the terminal block while power is applied. Reverse voltage and overvoltage protection are included.
Dip Switch:
Four switches are accessible through an opening at the side of the 9113 as shown in the image above. A switch is OFF when the slider is pushed down toward the product label. Currently switches one and three are not implemented. The operation of the 9113 is controlled by switch two and four. Do not change switch settings while power is applied to the 9113!
If switch two and four are off...
This is the normal run mode for the 9113. The Mode LED will flash amber when no session has been initiated by a PLC or the absence of activity by the PLC has caused a session to expire. The LED will flash green while a session is active. Refer to the theory of operation topic for more information about sessions.
If switch four is on and switch two is on or off...
This is a mode that allows the 9113 firmware to be updated. Refer to the help file included with the update utility for specific instructions.
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
If switch four is off and switch two is on...
This DHCP mode is used during initial setup, or when the IP address assigned to the 9113 is unknown, or when you attach it to a personal computer that is within a different subnet then the 9113. The IP Address Server utility is used to assign a temporary IP address to the 9113 so that the Web Utilities can be accessed.
Page 8
LED Indicators:
The five LEDs indicate the ongoing status of the 9113 during both Run and Utility modes. During power-up a checksum verification is made on the 9113 firmware. If the verification fails then the three LEDs on the front will light red and the micro controller will halt execution. This is a fatal error and may require a firmware download or factory repair.
Green Ethernet Activity LED:
This LED indicates network activity and will flash when nwtwork packets are received or sent.
Yellow Ethernet LED:
This LED currently has no specific function and may be on or off.
Serial Port LED:
The state of this LED is dependant on the operating mode of the 9113.
During active run mode...
The LED will light green when successful communications occurs with the Ultra 3000 and red when a response is not received from the Ultra 3000. A response failure will also cause the Fault LED to light and a fault to be logged into the internal Fault Register (mapped address B010:038).
Otherwise...
The LED is used in combination with the other LEDs during Firmware Update and its state is described within that topic.
Fault LED:
The state of this LED is dependant on the operating mode of the 9113.
During active run mode...
If the internal Fault Register is non-zero then the LED will be lit red. Once lit the LED will remain lit until the internal fault register is reset by the PLC or through a timed reset.
Otherwise...
The LED is used in combination with the other LEDs during Firmware Update and during initial power-up. Its state is described within those topics.
Mode LED:
The state of this LED is dependant on the operating mode of the 9113.
During active run mode...
The LED will flash amber when no session has been initiated by a PLC or the absence of activity by the PLC has caused a session to expire. The LED will flash green while at least one session is active. Access by Ultraware software will have no affect on this LED.
Otherwise...
The LED is used in combination with the other LEDs during Firmware Update and during initial power-up. Its state is described within those topics.
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
Page 9
9113 Power-up:
Power-up with DIP Switch 4 off...
When power is applied to the 9113 it will begin looking for an active ethernet network. During this time the Mode LED and Fault LED will be lit steady red and remain that way until an active network is detected. Once an active network is detected the Fault LED will turn off. If switch two is on (DHCP Mode) then the Mode LED will begin flashing red indicating it is requesting an IP address. Once the IP Address Server provides an address the Mode LED will begin flashing amber indicating it is ready to receive network requests from a PLC, Ultraware software, or the W eb Utilities browser. If switch two is off the assigned IP address is used and the Mode LED begins flashing amber while the Fault LED is turned off.
Power-up with DIP Switch 4 on...
This is firmware update mode. When power is applied to the 9113 and it will begin looking for an active ethernet network. During this time all LEDs will be off. Once an active network is detected the Mode LED will begin flashing red. Firmware update always uses DHCP mode. Refer to the Firmware Update topic for a description of the subsequent LED activity you can expect to see.
Internal Fault Register:
The internal fault register consists of sixteen bits and may be accessed by the PLC as B010:038. The bits indicate individual errors or faults that are recognized by the 9113 and are listed in the table below. The Web Utilities program can be used to allow the PLC to reset the fault and/or set a time period for fault reset.
Bit Number Fault Description Bit Number Fault Description
0 Invalid file type request 1 Invalid byte count request
2 Invalid file or element request 3 Invalid read/write function code
4 Invalid word number request 5 Open session failure
6 Ultraware access failure 7 Test mode running
8 Serial port bad reply 9 Serial port exception returned
10 Math fault 11 Serial port CTS failure
12 Serial port - No reply 13 Not assigned
14 Global Index Selector Fault 15 Fail safe
Refer to the 9113-1-X help file for additional information about the Fault Register. The help is available in the free configuration software of online at www.QuartechCorp.com.
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
Page 10
Physical Size and Mounting:
Dimensions in inches
The 9113 is enclosed in a rugged steel case and provides a DIN rail mounting clip that allows quick mounting and dismounting. To mount the 9113 tilt it forward and hook the clip to the top of the DIN rail. Rotate downward until the clip snaps onto the bottom of the DIN rail.
EN500-22-35 DIN Rail
To remove, slide a flat blade screwdriver under the bottom of the clip and twist until the clip releases, tilt forward, then pull upward to release from the top of the DIN rail.
PM 9113-1-X R evis ion 0
Model 9113-1-X Product Manual
Page 11
Ethernet Gateway for Ultraware:
The 9113-1-1 allows Allen-Bradley Ultraware software to access Ultra 3000 drives over an ethernet network when used in conjunction with the Quartech Ethernet Gateway program. The Ethernet Gateway program creates a virtual serial port that Ultraware will connect to. Your computer does not need to have an actual serial port. The gateway uses a node address to IP address mapping table to determine which drive to access on the ethernet network.
Quartech Ethernet Gateway Program